    Mainstream end-tidal carbon dioxide monitoring in the neonatal intensive care unit.

    Authors
    Rozycki HJ, Sysyn GD, Marshall MK, et al. 
    Source
    Pediatrics 1998 Apr; 101(4 Pt 1) :648-53.
    Abstract

    Continuous noninvasive monitoring of arterial carbon dioxide (CO2) in neonatal intensive care unit (NICU) patients would help clinicians avoid complications of hypocarbia and hypercarbia. End-tidal CO2 monitoring has not been used in this population to date, but recent technical advances and the introduction of surfactant therapy, which improves ventilation-perfusion matching, might improve the clinical utility of end-tidal monitoring.To determine the accuracy and precision of end-tidal CO2 monitoring in NICU patients.Nonrandomized recording of simultaneous end-tidal and arterial CO2 pairs.Two university NICUs.Forty-five newborn infants receiving mechanical ventilation who had indwelling arterial access, and a predefined subsample of infants who were <1000 g birth weight, <8 days of age, and who received surfactant therapy (extremely low birth weight -ELBW- <8).The correlation coefficient, degree of bias, and 95% confidence interval were determined for both the overall population and the ELBW <8 subgroup. Those factors which significantly influenced the bias were identified. The ability of the end-tidal monitor to alert the clinician to instances of hypocarbia or hypercarbia was determined.There were 411 end-tidal/arterial pairs analyzed from 45 patients. The correlation coefficient was 0.833 and the bias was -6. 9 mm Hg (95% confidence interval, +/-11.5 mm Hg). The results did not differ markedly in the ELBW <8 infants. Measures of the degree of lung disease, the ventilation index and the oxygenation index, had small influences on the degree of bias. This type of capnometry identified 91% of the instances when the arterial CO2 pressure was between 34 and 54 mm Hg using an end-tidal range of 29 to 45 mm Hg. End-tidal values outside this range had a 63% accuracy in predicting hypocarbia or hypercarbia.End-tidal CO2 monitoring in NICU patients is as accurate as capillary or transcutaneous monitoring but less precise than the latter. It may be useful for trending or for screening patients for abnormal arterial CO2 values.

    Mesh
    Capnography
    Carbon Dioxide
    Humans
    Infant, Newborn
    Infant, Very Low Birth Weight
    Intensive Care Units, Neonatal
    Logistic Models
    Monitoring, Physiologic
    Pulmonary Surfactants
    Respiration, Artificial
    Language

    eng

    Pub Type(s)
    Clinical Trial Comparative Study Journal Article Research Support, Non-U.S. Gov't
    PubMed ID

    9521950

    Content Manager
    Related Content

    Dose end-tidal carbon dioxide measurement correlate with arterial carbon dioxide in extremely low birth weight infants in the first week of life?

    Mainstream end-tidal carbon dioxide monitoring in ventilated neonates.

    A novel method of distal end-tidal CO2 capnography in intubated infants: comparison with arterial CO2 and with proximal mainstream end-tidal CO2.

    Detection of carbon dioxide thresholds using low-flow sidestream capnography in ventilated preterm infants.

    Good estimation of arterial carbon dioxide by end-tidal carbon dioxide monitoring in the neonatal intensive care unit.

    Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport.

    Transcutaneous monitoring of partial pressure of carbon dioxide in the elderly patient: a prospective, clinical comparison with end-tidal monitoring.

    End-tidal carbon dioxide monitoring in very low birth weight infants: correlation and agreement with arterial carbon dioxide.