- Incidental ethanol exposure from multiple household products: implications for phosphatidylethanol positivity. [Journal Article]Clin Biochem. 2026 Oct 31; 146:111220. [Online ahead of print]CB
- CONCLUSIONS: Concurrent exposure did not result in a measurable additive effect on POPEth concentrations under the conditions evaluated. Incidental exposure to these products is unlikely to meaningfully affect interpretation at established clinical decision thresholds; however, larger studies are warranted to confirm these findings.
- Publisher Full Text (DOI)
- Impact of Elecsys Folate III assay modifications on serum folate results and folate deficiency classification. [Journal Article]Clin Biochem. 2026 Oct 31; :111221. [Online ahead of print]CB
- CONCLUSIONS: Modifications of the Elecsys Folate III assay were temporally associated with substantial changes in serum folate measurements and an increase of more than 10 percentage points in the proportion of results below the laboratory-defined decision limit. These findings indicate that assay-related bias, particularly at low folate concentrations, may affect the estimates of the proportion of results below the laboratory-defined decision limit, and conclusions regarding the clinical utility and cost-effectiveness of serum folate testing. Analytical standardization should therefore be considered when interpreting serum folate data.
- Publisher Full Text (DOI)
- Analytical performance of new Optilite® C1q and C2 turbidimetric immunoassays and clinical performance in inherited and acquired complement abnormalities. [Journal Article]Clin Biochem. 2026 Oct 29; :111219. [Online ahead of print]CB
- CONCLUSIONS: These new C1q and C2 immunoassays are analytically robust and provide a more complete complement profile when used alongside functional and other quantitative antigen testing.
- Publisher Full Text (DOI)
- Method optimization and verification of homovanillic acid (HVA), vanillylmandelic acid (VMA) and 5-hydroxyindoleacetic acid (5-HIAA) on liquid chromatography tandem mass spectrometry (LC-MS/MS). [Journal Article]Clin Biochem. 2026 Oct 22; 146:111218. [Online ahead of print]CB
- CONCLUSIONS: We successfully optimized and verified the combination of a Chromsystems kit and laboratory developed method for measuring urinary HVA, VMA and 5-HIAA on our Waters LC-MS/MS.
- Publisher Full Text (DOI)
- Reframing liver test abnormalities after AAV gene therapy: a mechanistic diagnostic framework. [Review]Clin Biochem. 2026 Oct 08; 146:111217. [Online ahead of print]CB
- Hepatotoxicity remains one of the most frequent and clinically important safety concerns in adeno-associated virus (AAV) gene therapy. Yet the laboratory patterns observed after vector administration are biologically complex and often difficult to interpret. Alanine aminotransferase (ALT) and aspartate aminotransferase (AST) elevations are non-specific, as they may arise from AAV-induced innate a…
- Publisher Full Text (DOI)
- Implementation of a large automated Analyzer system in clinical biochemistry laboratories: A practical framework. [Editorial]Clin Biochem. 2026 Oct 07; :111212. [Online ahead of print]CB
- Automation has become essential in clinical biochemistry laboratories to meet increasing demands for efficiency, standardization, and reliable turnaround times. Large automated analyzer (LAA) systems are now central to modern laboratory operations and are frequently integrated within total laboratory automation solutions encompassing pre-analytical, analytical, and post-analytical workflows. Howe…
- Publisher Full Text (DOI)
- Hemoglobin-normalized thiamine diphosphate (vitamin B1) in whole blood: Reference intervals and clinical implications for status assessment. [Journal Article]Clin Biochem. 2026 Oct 05; 146:111215. [Online ahead of print]CB
- CONCLUSIONS: We established RI for Hb-normalized TDP according to CLSI methodology. Our findings support adopting ng/g Hb for TDP assessment, particularly in anemic patients.
- Publisher Full Text (DOI)
- Kidney-specific cell-free DNA as biomarker of kidney injury: Development and exploration of a multiplex digital droplet PCR assay. [Journal Article]Clin Biochem. 2026 Oct 03; 146:111216. [Online ahead of print]CB
- CONCLUSIONS: We developed a robust multiplex ddPCR assay to detect kidney-specific cfDNA. The early post-transplant peak supports its potential as a marker of kidney injury. Unlike donor-recipient-based approaches, this method directly quantifies organ damage and may be broadly applicable beyond transplantation.
- Publisher Full Text (DOI)
- Association between elevated serum cobalamin concentrations and malignancy: a retrospective cohort study from the western Cape, South Africa. [Journal Article]Clin Biochem. 2026 Oct 03; 146:111214. [Online ahead of print]CB
- CONCLUSIONS: In South African individuals without cobalamin supplementation, elevated serum cobalamin concentrations were independently associated with malignancy. Elevated concentrations should therefore increase the clinical index of suspicion for underlying malignancy, particularly solid tumours.
- Publisher Full Text (DOI)
- Integration of liquid chromatography-tandem mass spectrometry into total laboratory automation: technical challenges and clinical advantages. [Review]Clin Biochem. 2026 Oct 03; 146:111211. [Online ahead of print]CB
- The clinical laboratory is undergoing a paradigm shift toward the integration of liquid chromatography-tandem mass spectrometry(MS) into Total Laboratory Automation workflows. While historically relegated to specialized satellite units due to manual pre-analytical requirements, recent technological advancements have enabled the development of fully automated, 'sample-to-result' MS modules. This r…
- Publisher Full Text (DOI)
- Circulating phosphatidylserine as a plasma biomarker for clinical staging and prognostic prediction in Parkinson's disease: A diagnostic validation study. [Journal Article]Clin Biochem. 2026 Oct 01; 146:111213. [Online ahead of print]CB
- CONCLUSIONS: cPS levels correlate with PD severity, predict functional and cognitive decline, and exhibit stage-specific longitudinal changes, supporting cPS as a candidate biomarker for PD monitoring, though further validation is required.
- Publisher Full Text (DOI)
- Beyond downtime: cybersecurity, analytical integrity, and laboratory quality in clinical biochemistry. [Journal Article]Clin Biochem. 2026 Sep 22; 146:111210. [Online ahead of print]CB
- Publisher Full Text (DOI)
- Comment on "What are the correlates of laboratory productivity in clinical laboratories in the Asia Pacific region?" [Letter]Clin Biochem. 2026 Sep 21; 146:111187. [Online ahead of print]CB
- Publisher Full Text (DOI)
- Updated total calcium reference intervals for Abbott Alinity c using Calcium2 reagents. [Journal Article]Clin Biochem. 2026 Sep 20; 146:111209. [Online ahead of print]CB
- CONCLUSIONS: The RI for plasma total calcium on the Abbott Alinity c with CaNEW is lower than previously established.
- Publisher Full Text (DOI)
- Analytical performance specifications in the clinical laboratory: Historical evolution, conceptual foundations and a practical decision framework. [Review]Clin Biochem. 2026 Sep 17; 146:111208. [Online ahead of print]CB
- Analytical performance specifications (APS) represent a crucial part of analytical quality. Laboratories use APS in the forms of total error (TE), imprecision, bias and measurement uncertainty (MU) to accurately assess the quality of the analytical phase. This narrative review summarizes the history and evolution of APS. It also reviews the current consensus on APS models as represented by the 20…
- Publisher Full Text (DOI)