- Towards the clinical integration of an image-guided navigation system for percutaneous liver tumor ablation using freehand 2D ultrasound images. [Journal Article]
- Primary and metastatic liver tumors constitute a significant challenge for contemporary medicine. Several improvements are currently being developed and implemented to advance image navigation systems for percutaneous liver focal lesion ablation in clinical applications at the diagnosis, planning and intervention stages. First, the automatic generation of an anatomically accurate parametric model…
- Publisher Full Text (DOI)
- Novel method for setting up 3D navigation system with skin-fixed dynamic reference frame in anterior cervical surgery. [Journal Article]
- CONCLUSIONS: 3D navigation system with skin-fixed DRF in anterior cervical surgery is a simple and reliable method and it can be a helpful supplement to a spine surgeon's judgement.
- Publisher Full Text (DOI)
- Numerical simulation of blood flow and plaque progression in carotid-carotid bypass patient specific case. [Case Reports]Comput Aided Surg. 2015; 20(1):1-6.CA
- This study describes computer simulation of blood flow and plaque progression pattern in a patient who underwent surgical treatment for infected carotid prosthetic tube graft using carotid-carotid cross-over bypass. The 3D blood flow is governed by the Navier-Stokes equations, together with the continuity equation. Mass transfer within the blood lumen and through the arterial wall is coupled with…
- Publisher Full Text (DOI)
- Prediction of post-operative range of motion using intra-operative soft tissue balance in total knee arthroplasty with navigation. [Journal Article]
- This study evaluated the influence of intra-operative soft tissue balance on post-operative range of motion in patients undergoing posterior-stabilized total knee arthroplasty with navigation. After implantation of all components in 31 consecutive patients, the joint component gap was measured manually with the knee at 0°, 90°, and 120° as guided by a navigation system. We designated soft tissue …
- Publisher Full Text (DOI)
- A comparison of two surgical approaches in functional neurosurgery: individualized versus conventional stereotactic frames. [Journal Article]
- CONCLUSIONS: Individualized miniframes such as the Starfix® miniframe allow implantation of DBS electrodes in IPD that is equally effective as conventional systems. The time efficiency achieved in surgery using of the Starfix® system helps to minimize patients' discomfort during DBS surgery.
- Publisher Full Text (DOI)
- Robot-assisted primary cementless total hip arthroplasty with a short femoral stem: a prospective randomized short-term outcome study. [Randomized Controlled Trial]
- CONCLUSIONS: The present study suggested that robot-assisted short stem THA could increase the accuracy of stem alignment, improve leg length equality, and help reduce the risk of intraoperative femoral fracture as compared with manual rasping. However, the clinical outcome scores did not differ between the two groups at the time of short-term follow-up. Long-term follow-up is needed to determine whether there will be a long-term clinical relevance of robot-assisted implantation of short femoral stems in THA.
- Publisher Full Text (DOI)
- A comparison of registration errors with imageless computer navigation during MIS total knee arthroplasty versus standard incision total knee arthroplasty: a cadaveric study. [Journal Article]
- Optimal component alignment in total knee arthroplasty has been associated with better functional outcome as well as improved implant longevity. The ability to align components optimally during minimally invasive (MIS) total knee replacement (TKR) has been a cause of concern. Computer navigation is a useful aid in achieving the desired alignment although it is limited by the error during the manu…
- Publisher Full Text (DOI)
- One-step reconstruction with a 3D-printed, biomechanically evaluated custom implant after complex pelvic tumor resection. [Case Reports]
- Resection of a pelvic tumor is challenging because of its complex three-dimensional (3D) anatomy and deep-seated location with nearby vital structures. The resection is technically demanding if a custom implant is used for reconstruction of the bone defect as the surgeon needs to ensure the resection margin is sufficiently wide and the orientation of intended resection planes must match that of t…
- Publisher Full Text (DOI)
- Effects of coordinate-system construction methods on postoperative computed tomography evaluation of implant orientation after total hip arthroplasty. [Journal Article]
- CONCLUSIONS: We recommend referring to preoperative RPs when choosing postoperative RPs. Surgeons must be aware that for evaluation of postoperative stem anteversion, manual methods may produce considerable error.
- Publisher Full Text (DOI)
- Quantitative analysis of velopharyngeal movement using a stereoendoscope: accuracy and reliability of range images. [Journal Article]
- CONCLUSIONS: The optimal distance from the camera to an object is <6.5 cm. The present endoscopic measuring system can provide stable range images of the velopharynx when using an appropriate fixation method and enables quantitative analysis of velopharyngeal movements.
- Publisher Full Text (DOI)
- Non-invasive quantification of lower limb mechanical alignment in flexion. [Journal Article]
- CONCLUSIONS: Acceptable precision and accuracy may be possible when measuring knee kinematics in early flexion using a non-invasive system; however, we do not believe passive trackers should be mounted with rubber strapping such as was used in this study. Flexing the knee appears to decrease the precision and accuracy of the system. The functions of this new software using image-free navigation technology have many potential clinical applications, including assessment of bony and soft tissue deformity, pre-operative planning, and post-operative evaluation, as well as in further pure research comparing kinematics of the normal and pathological knee.
- PMC Free PDF
- Evaluation of a computational model to predict elbow range of motion. [Journal Article]
- Computer models capable of predicting elbow flexion and extension range of motion (ROM) limits would be useful for assisting surgeons in improving the outcomes of surgical treatment of patients with elbow contractures. A simple and robust computer-based model was developed that predicts elbow joint ROM using bone geometries calculated from computed tomography image data. The model assumes a hinge…
- PMC Free PDF
- Automated registration of optical coherence tomography and dermoscopy in the assessment of sub-clinical spread in basal cell carcinoma. [Journal Article]
- Optical coherence tomography (OCT) has been shown to be of clinical value in imaging basal cell carcinoma (BCC). A novel dual OCT-video imaging system, providing automated registration of OCT and dermoscopy, has been developed to assess the potential of OCT in measuring the degree of sub-clinical spread of BCC. Seventeen patients selected for Mohs micrographic surgery (MMS) for BCC were recruited…
- PMC Free PDF
- RapidSplint: virtual splint generation for orthognathic surgery - results of a pilot series. [Journal Article]
- CONCLUSIONS: In this pilot study it was demonstrated that clinically usable splints for orthognathic surgery can be produced by computer-assisted technology. Virtual splint design was realized by RapidSplint®, an in-house software platform which might contribute in future to shorten preoperative workflows for the production of orthognathic surgical splints.
- PMC Free PDF
- Methods for abdominal respiratory motion tracking. [Journal Article]
- Non-invasive surface registration methods have been developed to register and track breathing motions in a patient's abdomen and thorax. We evaluated several different registration methods, including marker tracking using a stereo camera, chessboard image projection, and abdominal point clouds. Our point cloud approach was based on a time-of-flight (ToF) sensor that tracked the abdominal surface.…
- PMC Free PDF