- Influence of Screw Diameter on the Pull-Out Resistance of Additively Manufactured Auxetic Bone Screws in Cancellous and Cortical Bone. [Journal Article]Med Eng Phys. 2026 Oct 01. [Online ahead of print]ME
- This study investigates the effect of screw diameter on the pull-out strength of a bone screw with a loosening-resistant auxetic structure manufactured using additive manufacturing. The variation in mechanical performance depending on screw diameter was examined experimentally and through finite element analysis in cancellous and cortical bone structures. First, screw designs with different diame…
- Publisher Full Text (DOI)
- Shear Rate and Temperature Dependent Characterization of Blood-Mimicking Fluids for Blood Warming Device Application. [Journal Article]Med Eng Phys. 2026 Sep 30. [Online ahead of print]ME
- During emergency transfusion, stored whole blood at 1-6°C must be rapidly warmed to 36-38°C using blood warming devices. However, device validation commonly relies on Newtonian crystalloid intravenous fluids with a viscosity of 1 mPa·s, whereas whole blood exhibits temperature-dependent, shear-thinning rheology with viscosities of 3.5-4.5 mPa·s at 37°C. This discrepancy introduces systematic erro…
- Publisher Full Text (DOI)
- Application of Machine Learning Techniques in the Measurement of Ground Reaction Force (GRF) waveforms using Inertial Measurement Unit (IMU) Sensors -A Systematic Literature Review. [Journal Article]Med Eng Phys. 2026 Sep 30. [Online ahead of print]ME
- Three-dimensional ground reaction forces (GRFs) are important parameters in human motion analysis, yet their measurement is confined to laboratory settings. GRF estimation from wearable inertial measurement unit (IMU) data using machine learning and deep learning has emerged as a promising avenue for kinetic analysis outside the laboratory, but no consensus on standardized methods or best practic…
- Publisher Full Text (DOI)
- Federated Simplex-Constrained Network for Fine-Grained Clock Drawing Test Scoring and Cognitive Pattern Representation. [Journal Article]Med Eng Phys. 2026 Sep 25. [Online ahead of print]ME
- The Clock Drawing Test is a core tool for the early screening of cognitive impairment. Traditional manual methods are time-consuming and prone to significant subjective bias, while most existing automated methods are "black-box" approaches that directly map images to scores or category labels. Not only do these methods lack interpretability in their decision-making processes, but they also fail t…
- Publisher Full Text (DOI)
- Technical evaluation of transport-derived movement trajectories during knee osteoarthritis rehabilitation. [Journal Article]Med Eng Phys. 2026 Sep 25. [Online ahead of print]ME
- Wearable inertial sensors enable repeated movement recording during knee osteoarthritis rehabilitation, but methods for summarizing multivariable changes across routine sessions remain exploratory. This retrospective technical evaluation examined a normalized transport-derived deviation (NTD) constructed from paired shank-mounted inertial measurement units. Seven participants contributed 46 paire…
- Publisher Full Text (DOI)
- Image-Enhanced Autonomous Navigation in Intestinal Robotics: A Threshold-Triggered Approach Combining Dark-Area Localization and Morphological Contour GuidanceShort title: Enhancing Visibility and Navigation Precision in Confined Spaces. [Journal Article]Med Eng Phys. 2026 Sep 23. [Online ahead of print]ME
- Robotic endoscopy offers a potential route to autonomous gastrointestinal navigation. However, autonomous intestinal navigation is hindered by non-rigid lumen deformation and visual degradation from specular reflections, which compromise accurate perception and stable control. We propose a threshold-triggered, vision-driven framework incorporating Navier-Stokes-based highlight suppression. Algori…
- Publisher Full Text (DOI)
- Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate. [Journal Article]Med Eng Phys. 2026 Sep 23. [Online ahead of print]ME
- Rigid limb surrogates transfer full mechanical loads directly to the prosthetic socket during structural testing, causing premature distal failure and underestimating of actual load capacity. In contrast, soft-compliant surrogates buffer applied loads and enables realistic structural deformation. This study investigates: (i) the influence of rigid Plaster of Paris (PoP) versus biofidelic hyperela…
- Publisher Full Text (DOI)
- Reliability and comparative evaluation of novel multi-segment kinematic foot model incorporating detailed midfoot kinematics during gait: single-examiner study. [Journal Article]Med Eng Phys. 2026 Sep 18. [Online ahead of print]ME
- The accurate assessment of midfoot motion during gait presents a considerable methodological challenge in biomedical measurement and modelling. This study developed and evaluated the intra-session repeatability of the Oita foot model, a novel multi-segment kinematic foot model that incorporates a dedicated midfoot segment defined by three markers on the dorsal cuneiform and cuboid to minimize sof…
- Publisher Full Text (DOI)
- Feasibility of quantifying intra-fractional patient positional error for head and neck IMRT using radiomic features of EPID-measured fluence maps: a phantom study. [Journal Article]Med Eng Phys. 2026 Sep 30; 147(9).ME
- This study aimed to evaluate the feasibility of estimating patient positional errors during head-and-neck fixed-field intensity-modulated radiation therapy (IMRT) using a machine-learning (ML) regression models based on radiomics features of patient-transmitted fluence maps acquired by an electronic portal imaging device (EPID), as a proof-of-concept toward quantitative intrafractional monitoring…
- Publisher Full Text (DOI)
- Reliability-aware transfer learning with BEATs for variable-length respiratory sound classification: a patient-disjoint evaluation in two public databases. [Journal Article]Med Eng Phys. 2026 Sep 25; 147(9).ME
- Random or central placement of respiratory sounds within padded windows can cause length-based masks to exclude recorded audio. We developed an exact support-propagation interface for the pretrained bidirectional encoder representation from audio transformers (BEATs), mapping sample support through filterbank frames and patch tokens to attention and pooling masks. We evaluated this interface alon…
- Publisher Full Text (DOI)
- Honest and Reliable Evaluation and Expert Equivalence Testing of Automated Neonatal Seizure Detection. [Journal Article]Med Eng Phys. 2026 Sep 25; 147(9).ME
- Reliable evaluation of machine learning models for neonatal EEG seizure detection is a prerequisite for accurate performance assessment and comparison of methods. Model evaluation, however, is complicated by severe class imbalance and uncertain ground truth. To address these limitations, we propose evidence-based reporting recommendations tailored to the specific challenges of neonatal seizure de…
- Publisher Full Text (DOI)
- Loading Effects: Geometry versus Intrinsic Forces in Injury Risk Assessment of the Femur in Children with Osteogenesis Imperfecta. [Journal Article]Med Eng Phys. 2026 Sep 15. [Online ahead of print]ME
- Osteogenesis imperfecta (OI) is a rare genetic disorder but is the most common disorder of bone etiology with little known about the impact of physiologic factors on fracture risk. Finite element analysis (FE) models of OI bone have been previously developed to examine fracture risk during ambulation and various daily activities of the femur and tibia. This study aims to further investigate the i…
- Publisher Full Text (DOI)
- Volume-constrained wall motion alters left atrial appendage hemodynamic descriptors: a CFD sensitivity study. [Journal Article]Med Eng Phys. 2026 Sep 25; 147(9).ME
- Rigid-wall left atrium (LA) and left atrial appendage (LAA) computational fluid dynamics models are practical but suppress deformation-driven transport, whereas image-derived wall motion is data- and processing-intensive. We evaluated whether a reduced-order, volume-constrained wall-motion prescription changes computed LA/LAA hemodynamic descriptors relative to a static-wall approximation. A pati…
- Publisher Full Text (DOI)
- Portable RGB-D stabilometry for unsupervised postural assessment in Antarctic field conditions. [Journal Article]Med Eng Phys. 2026 Sep 23; 147(9).ME
- Portable quantification of postural sway remains challenging in remote and resource-limited environments where laboratory force platforms and motion-capture systems are impractical. We evaluated an autonomous RGB-D stabilometry workflow during an Antarctic expedition by comparing camera-derived center-of-mass (CoM) sway with a portable center-of-pressure (CoP) reference and testing leave-one-subj…
- Publisher Full Text (DOI)
- Feasibility and accuracy of low-angle, non-orthogonal biplane fluoroscopic 2D-3D registration for dynamic analysis of the thumb carpometacarpal joint. [Journal Article]Med Eng Phys. 2026 Sep 18; 147(9).ME
- Background.Accurate three-dimensional dynamic assessment of the thumb carpometacarpal (CMC) joint is important for understanding the pathomechanics of CMC osteoarthritis and evaluating treatment outcomes. Intensity-based biplane 2D-3D registration is a promising approach for dynamic bone motion analysis; however, conventional orthogonal biplane configurations are often difficult to implement for …
- Publisher Full Text (DOI)