- Feasibility of canine minibeam radiotherapy (MBRT) with a dual-robot kilovoltage x-ray system. [Journal Article]Phys Med Biol. 2026 Oct 23. [Online ahead of print]PM
- To evaluate the feasibility of delivering minibeam radiotherapy (MBRT) to a canine glioblastoma patient using a novel low-cost dual-robot kilovoltage (kV) x-ray system. 
 
Approach: A workflow to perform MBRT using a tungsten collimator with 300 μm slits was developed for the 225 kVp x-ray source system. A Monte Carlo (MC) model of MBRT was built in TOPAS and validated with EBT4 measureme…
- Publisher Full Text (DOI)
- Hardware ray-traced optical-photon Monte Carlo for radiation detector simulation: a TOPAS extension on Apple Silicon. [Journal Article]Phys Med Biol. 2026 Oct 22. [Online ahead of print]PM
- Optical-photon Monte Carlo (MC) underlies scintillator dosimetry, Cherenkov imaging and other medical-physics applications, yet Geant4 transport of the 105-106optical photons per event on the central processing unit (CPU) makes dataset-scale studies impractical even on a multi-core workstation. We implement and verify a hardware ray-tracing optical-photon transport extension for TOPAS on Apple Si…
- Publisher Full Text (DOI)
- Scatter correction for multi-source linear static CT via a geometry-aware parameter regression network with differentiable forward modeling. [Journal Article]Phys Med Biol. 2026 Oct 22. [Online ahead of print]PM
- CONCLUSIONS: GAPR-Net provides a physically interpretable and computationally efficient approach for correcting non-stationary asymmetric scatter artifacts in SLCT.
.
- Publisher Full Text (DOI)
- Spot-wise compensation of proton beam deflection and radiation field deformation in the transverse magnetic field of an in-beam MR scanner using a research version of a commercial treatment planning system. [Journal Article]Phys Med Biol. 2026 Oct 22. [Online ahead of print]PM
- Objective
Magnetic resonance-integrated proton therapy (MRiPT) offers the potential for high-precision, image-guided particle therapy but is challenged by magnetic field (MF)-induced proton beam deflection and radiation field deformation. Unless compensated for, these effects compromise dose conformity and prohibit clinical implementation. This work aims to develop and experimentally validate…
- Publisher Full Text (DOI)
- Radiobiological dosimetry using hybrid imaging-derived spatiotemporal dose distributions for131I therapy of metastatic thyroid cancer. [Journal Article]Phys Med Biol. 2026 Oct 22. [Online ahead of print]PM
- CONCLUSIONS: The proposed framework enables patient-specific voxelwise radiobiological modeling through TCP using one quantitative SPECT/CT acquisition and serial planar imaging. It may support biologically informed activity prescription, although its model-dependent predictions require clinical validation.
- Publisher Full Text (DOI)
- Automated carotid artery atherosclerotic inflammation segmentation in PET using MSR-Net. [Journal Article]Phys Med Biol. 2026 Oct 21. [Online ahead of print]PM
- Abstract
Objective. To develop an automated method for segmentation and uptake quantification of
carotid atherosclerotic inflammation on 64Cu-CANF-comb PET while accounting for
partial-volume and tissue-fraction effects.
Approach. Synthetic carotid PET images with known fractional-volume ground truth were
generated by combining MR-derived high-resolution activity maps with GAT…
- Publisher Full Text (DOI)
- An experimentally calibrated nanodosimetry-based framework for predicting LET-dependent relative biological effectiveness in proton boron capture therapy. [Journal Article]Phys Med Biol. 2026 Oct 21. [Online ahead of print]PM
- CONCLUSIONS: An experimentally calibrated framework integrating MC simulation, nanodosimetry, radiobiological experiments, and the LNDM was established for LET-dependent PBCT RBE prediction based on biological calibration data. PBCT showed consistently higher RBE than proton therapy, with a greater advantage at higher LET, supporting future biological optimization of PBCT.
- Publisher Full Text (DOI)
- Time-aware frame-aligned diffusion-inspired model for late dynamic PET frame prediction from early [11C] raclopride. [Journal Article]Phys Med Biol. 2026 Oct 21. [Online ahead of print]PM
- CONCLUSIONS: The proposed framework provides deterministic time-resolved late-frame estimates from early dynamic PET while using a DDPM-inspired noise-prediction objective only as an auxiliary training regularizer rather than as an iterative diffusion inference process. This design may support shortened dynamic PET protocols while retaining TAC and kinetic-parameter fidelity.
- Publisher Full Text (DOI)
- Enhancements and reference internal dosimetry data for the MOBY whole-body computational phantom of the laboratory mouse. [Journal Article]Phys Med Biol. 2026 Oct 21. [Online ahead of print]PM
- CONCLUSIONS: The refined MOBY phantoms provide a critical advancement in preclinical dosimetry by incorporating sex-specific anatomical details, an improved skeletal model, and enhanced organ-level dose assessments. These phantoms will facilitate dose-response radiopharmaceutical research and support the integration of murine dosimetry models into human dose estimation frameworks.
- Publisher Full Text (DOI)
- Influence of x-ray beam quality on retrospective bone dose estimation in a murine model: experimental investigation of EPR signal kinetics and computational modeling. [Journal Article]Phys Med Biol. 2026 Oct 21. [Online ahead of print]PM
- In the context of radiological accidents, retrospective dosimetry methods such as electron paramagnetic resonance (EPR) spectroscopy and Monte Carlo simulation are used for dose reconstruction. EPR analysis of bone biopsies allows experimental assessment of absorbed dose. However, several factors may affect EPR dose estimation. The time delay between irradiation and sampling can lead to underesti…
- Publisher Full Text (DOI)
- Electron specific absorbed fractions for the ICRP family of mesh-type reference computational phantoms. [Journal Article]Phys Med Biol. 2026 Oct 21. [Online ahead of print]PM
- CONCLUSIONS: To the authors' knowledge, this is the first study to provide complete electron SAF datasets spanning all ICRP MRCPs with expanded source-target combinations.
- Publisher Full Text (DOI)
- Correction of arterial input-function saturation for extraction fraction estimation in retinal fluorescein videoangiography. [Journal Article]Phys Med Biol. 2026 Oct 21. [Online ahead of print]PM
- CONCLUSIONS: The correction framework converts modest AIF saturation from a restrictive acquisition limit into a manageable analytical condition. This broader operating range is valuable for 8-bit FVA, supporting acquisition near the detector ceiling to improve tissue signal and enable high-resolution E mapping without dual-bolus acquisition.
- Publisher Full Text (DOI)
- Untangling the causes of elongation artifacts in dual flat-panel PET: limited angular sampling versus parallax error. [Journal Article]Phys Med Biol. 2026 Oct 21. [Online ahead of print]PM
- CONCLUSIONS: The framework predicts the dominant artifact mechanism as a function of object size, position, and system geometry. The insights guide detector and system design for dual flat-panel PET and corresponding artifact correction methods.
- Publisher Full Text (DOI)
- Nonlinear stability phenotypes and collapse dynamics of multi-organ radiomics in total-body PET imaging: toward digital twin-oriented robustness assessment. [Journal Article]Phys Med Biol. 2026 Oct 20. [Online ahead of print]PM
- Radiomics analysis in PET offers a high-dimensional representation of tissue characteristics, yet its reliability is limited by sensitivity to acquisition perturbations, particularly dose reduction. This study aims to introduce a nonlinear stability phenotyping framework to characterize dose-response behavior of multi-organ radiomics and evaluate their potential relevance for future digital twin-…
- Publisher Full Text (DOI)