- From whole-body dosimetry to local dose assessment: a 3-y experience in interventional practice. [Journal Article]Radiat Prot Dosimetry. 2026 Oct 16. [Online ahead of print]RP
- This 3-y retrospective study analyzed 180 paired dosimetry records from five interventional radiologists and five cardiologists, comparing whole-body Hp(10) with eye-lens Hp(3) and extremity Hp(0.07) doses. Moderate-to-strong linear correlations were observed (r = 0.86-0.91, R2 = 0.73-0.83), indicating that chest-level dosemeters may support the estimation of localized exposure. Coefficients of v…
- Publisher Full Text (DOI)
- Indoor radon exposure in Obuasi mining community: influence of dwelling materials and annual effective dose assessment. [Journal Article]Radiat Prot Dosimetry. 2026 Oct 12. [Online ahead of print]RP
- This study assessed indoor radon (222Rn) concentrations across 150 dwellings in Obuasi, Ghana, using CR-39 SSNTDs over a 180-day period. The influence of wall construction materials (concrete, sandcrete, clay, and wood), interior finishes (paint and paper plaster), and floor variations (mortar and tile) on radon levels were evaluated alongside soil (226Ra) activity and 222Rn exhalation rates. Ind…
- Publisher Full Text (DOI)
- Evaluation of high-dose alerts in computed tomography using an automated dose monitoring system: a retrospective institutional study. [Journal Article]Radiat Prot Dosimetry. 2026 Oct 09. [Online ahead of print]RP
- Radiation dose monitoring software (DMS) tools are increasingly used to support automated monitoring of radiation dose in medical imaging. This study evaluated the frequency and causes of high-dose events detected by a DMS in computed tomography (CT). All CT examinations performed at one hospital across three CT scanners over a one-year period were retrospectively analysed to establish the freque…
- Publisher Full Text (DOI)
- External dose characteristics and radiation-protection metrics after permanent 125I prostate brachytherapy: comparison of conventional and sparse implantation techniques. [Journal Article]Radiat Prot Dosimetry. 2026 Oct 07. [Online ahead of print]RP
- This study compared external dose rates and radiation protection metrics between the conventional whole-gland technique (CWT) and sparse implantation technique (SIT) in 100 patients (50 each with CWT and SIT) undergoing permanent 125I prostate brachytherapy. External dose rates were measured at various distances from the anterior body surface at 1 and 30 days post-procedure. Time-dependent dose r…
- Publisher Full Text (DOI)
- Measured fetal-region dose in X-ray pelvimetry and low-dose computed tomography using a realistic pregnant phantom: a comparative study. [Journal Article]Radiat Prot Dosimetry. 2026 Oct 07. [Online ahead of print]RP
- This study evaluated fetal-region doses and dose distributions for X-ray pelvimetry (Guthmann and Martius methods) using exposure conditions from a nationwide survey in Japan and compared them with those of a low-dose computed tomography (CT) protocol using a realistic late-pregnancy phantom. A pregnancy model phantom combining an anthropomorphic phantom with a custom-made abdominal phantom was u…
- Publisher Full Text (DOI)
- Long-term persistence of 137Cs in forest humus of the Czech Republic: a 25-year monitoring perspective. [Journal Article]Radiat Prot Dosimetry. 2026 Oct 05. [Online ahead of print]RP
- Forest floor humus is a long-term reservoir of radiocaesium, but its behaviour decades after the Chernobyl accident remains incompletely understood. In 2020, 283 humus samples from Czech coniferous forests were analysed for 137Cs, 40K, and 210Pb activities, element contents and site characteristics. 137Cs activity ranged from 6.26 to 931 Bq kg-1, with a geometric mean (GM) of 90.5 Bq kg-1. At 157…
- Publisher Full Text (DOI)
- Occupational chronic myeloid leukaemia in a radiology technician: a quantitative Probability of Causation assessment. [Journal Article]Radiat Prot Dosimetry. 2026 Sep 30. [Online ahead of print]RP
- Chronic myeloid leukaemia (CML) is a clonal myeloproliferative neoplasm associated with the Philadelphia chromosome, and ionizing radiation is a well-established leukemogenic factor. Despite regulated dose limits, occupationally related CML remains rare and under-recognized. We present the case of a 53-year-old male radiology technician diagnosed with CML following the detection of leukocytosis d…
- Publisher Full Text (DOI)
- The impact of breast shielding on radiation dose during computed tomography procedures. [Journal Article]Radiat Prot Dosimetry. 2026 Sep 30. [Online ahead of print]RP
- To quantify and compare breast radiation dose across CT protocols using shielding and automatic tube current modulation (ATCM) in single- and dual-energy scanning modes. Surface breast dose was measured using a calibrated pencil ionization chamber placed in a female anthropomorphic phantom. Scans were performed on a 128-slice CT system across multiple anatomical regions using manual mA, ATCM, lea…
- Publisher Full Text (DOI)
- Estimation of global population-weighted annual eye lens dose from cosmic ray exposure. [Journal Article]Radiat Prot Dosimetry. 2026 Sep 25. [Online ahead of print]RP
- This study presents the application of an analytical model, PARMA, to estimate the population-weighted annual absorbed dose to the lens of the eye due to cosmic rays. Cosmic ray flux data incorporating geographical altitude, together with the global population data from 2020, were used to estimate the global population-weighted annual eye lens dose. The resulting value was 0.267 mGy, ~11% lower t…
- Publisher Full Text (DOI)
- Evaluation of the KERMA approximation method in Monte Carlo dose calculations for BNCT involving a realistic 3D patient phantom. [Journal Article]Radiat Prot Dosimetry. 2026 Sep 21. [Online ahead of print]RP
- Monte Carlo (MC) methods are generally recognized as the gold standard for dose calculations. However, achieving high statistical confidence is computationally expensive, particularly when complex secondary particles are involved. Kinetic Energy Released in Matter (KERMA) approximation method is a variance reduction technique widely used in MC simulations. This study evaluated the accuracy and ef…
- Publisher Full Text (DOI)
- Detection, identification, and management of alpha-emitting radioactive waste in scrap metal: a case study from Kosovo. [Journal Article]Radiat Prot Dosimetry. 2026 Sep 17. [Online ahead of print]RP
- Detection and management of alpha (α)-emitting radioactive sources in scrap metal present a significant challenge for radiological safety, particularly in countries lacking infrastructure for the final disposal of radioactive waste. This paper presents a case study from Kosovo addressing the detection, identification, dose measurement, and isolation of an alpha-emitting radioactive source discove…
- Publisher Full Text (DOI)
- Low-frequency magnetic flux density levels in various exposure scenarios: a measurement-based study. [Journal Article]Radiat Prot Dosimetry. 2026 Sep 17. [Online ahead of print]RP
- The increasing exposure to low-frequency electromagnetic fields has raised significant concerns regarding its potential effects on human health and the environment. At the same time, it has spurred growing interest in identifying low-exposure scenarios to support green and sustainable objectives. This study presents the results of in situ measurements of magnetic flux density across various expos…
- Publisher Full Text (DOI)
- Influence of collimation on radiation exposure during chest radiography. [Journal Article]Radiat Prot Dosimetry. 2026 Sep 11. [Online ahead of print]RP
- The aim was to assess the impact of collimation on the field of view, dose-area product, effective dose, and absorbed dose to organs located in or near the primary beam. Data were collected using two Siemens radiography units. Imaging was performed under standard clinical protocols in posteroanterior (PA) and lateral projections. Images from 372 patients aged 18 years or older were randomly selec…
- Publisher Full Text (DOI)
- Regulatory survey of ambient dose equivalent rates around baggage scanners in Tanzania. [Journal Article]Radiat Prot Dosimetry. 2026 Sep 11. [Online ahead of print]RP
- The deployment of baggage scanners in airports and public facilities requires periodic radiation surveys to ensure occupational safety and regulatory compliance. This study assessed ambient dose equivalent rates (H* (10)) around baggage scanners at selected airports, ports, and commercial facilities. Measurements were taken at: 1 m from the entry and exit points, 2 m from the scanner, and the con…
- Publisher Full Text (DOI)
- Spatial distribution of X-ray attenuation in a full-face shield: a multipoint in vivo study in interventional cardiology. [Journal Article]Radiat Prot Dosimetry. 2026 Sep 09. [Online ahead of print]RP
- Occupational radiation exposure remains a critical concern in interventional cardiology, particularly regarding brain and ocular protection. This study evaluates the protective efficacy of a 0.12 mmPb leaded acrylic full-face shield through a series of comprehensive in vivo dose measurements conducted on a primary cardiologist during real-time fluoroscopy procedures. The cardiologist was equipped…
- Publisher Full Text (DOI)