Unbound MEDLINE

Presbyopia journal articles from PubMed MEDLINE database

Unbound MEDLINE results for:Bookmark this site
Presbyopia[MH]| Refine this search
1 - 10 of 862 journal articles in the PubMed databaseEmail to a friend    
 
de Ortueta D 
Is peripheral presbyLASIK a center-distance technique? [Comment, Letter]
J Refract Surg 2008 Jun; 24(6):561; author reply 562.
Full Citation | Find Related Articles 
Gobin L, Trau R, Tassignon MJ 
[In Process Citation] [English Abstract, Journal Article]
Bull Soc Belge Ophtalmol 2008; (307):27-36.
Abstract | Full Citation | Find Related Articles 
Illueca C, Alió JL, Mas D, et al. 
Pseudoaccommodation and visual acuity with Technovision presbyLASIK and a theoretical simulated Array multifocal intraocular lens. [Journal Article, Research Support, Non-U.S. Gov't]
J Refract Surg 2008 Apr; 24(4):344-9.
Abstract | Full Citation
Marchini G, Pedrotti E, Modesti M, et al. 
Anterior segment changes during accommodation in eyes with a monofocal intraocular lens: High-frequency ultrasound study. [Journal Article]
J Cataract Refract Surg 2008 Jun; 34(6):949-56.
Abstract | Full Citation
Pinelli R, Ortiz D, Simonetto A, et al. 
Correction of presbyopia in hyperopia with a center-distance, paracentral-near technique using the Technolas 217z platform. [Journal Article, Research Support, Non-U.S. Gov't]
J Refract Surg 2008 May; 24(5):494-500.
Abstract | Full Citation | Find Related Articles 
Win-Hall DM, Glasser A 
Objective accommodation measurements in prepresbyopic eyes using an autorefractor and an aberrometer. [Journal Article]
J Cataract Refract Surg 2008 May; 34(5):774-84.
Abstract | Full Citation | Publisher Full Text | Find Related Articles 
Montés-Micó R, Ferrer-Blasco T, Charman WN, et al. 
Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens. [JOURNAL ARTICLE]
J Cataract Refract Surg 2008 May; 34(5):763-768.
Abstract | Full Citation
Er H 
Correspondence. [Journal Article]
Retina 2008 May; 28(5):783.
Full Citation | Find Related Articles 
Durrie D, McMinn PS 
Computer-based primary visual cortex training for treatment of low myopia and early presbyopia. [Journal Article]
Trans Am Ophthalmol Soc 2007.:132-8; discussion 138-40.
Abstract | Full Citation | Find Related Articles 
Patel S, Alió JL, Feinbaum C 
Comparison of Acri.Smart multifocal IOL, crystalens AT-45 accommodative IOL, and Technovision presbyLASIK for correcting presbyopia. [Journal Article, Research Support, Non-U.S. Gov't]
J Refract Surg 2008 Mar; 24(3):294-9.
Abstract | Full Citation | Find Related Articles 
New Search Next Results
  
Medical References for Treo, iPhone or Blackberry!

Advertise on this site.