| Hauser RG, Almquist AK Learning from our mistakes? Testing new ICD technology. [Journal Article] N Engl J Med 2008 Dec 11; 359(24):2517-9. Full Citation | Publisher Full Text | Find Related Articles | | Baas J Adjuvant therapies of bone graft around non-cemented experimental orthopedic implants stereological methods and experiments in dogs. [Journal Article, Research Support, N.I.H., Extramural, Research Support, Non-U.S. Gov't] Acta Orthop Suppl 2008 Aug; 79(330):1-43. Abstract | Full Citation | | [Smoking and alcohol abuse, risk factors of aseptic instability of hip endoprostheses] [English Abstract, Journal Article] Vestn Ross Akad Med Nauk 2008; (9):6-12. Abstract | Full Citation | | Lee T Ask the doctor. How do I know when my new valve isn't working correctly? [Journal Article] Harv Heart Lett 2008 Oct; 19(2):8. Full Citation | Find Related Articles | | Mäkelä K, Eskelinen A, Pulkkinen P, et al. Cemented total hip replacement for primary osteoarthritis in patients aged 55 years or older: results of the 12 most common cemented implants followed for 25 years in the Finnish Arthroplasty Register. [Journal Article] J Bone Joint Surg Br 2008 Dec; 90(12):1562-9. Abstract | Full Citation | Publisher Full Text | Find Related Articles | | Cruden NL, Harding SA, Newby DE Coronary stent thrombosis in the perioperative period. [Editorial] BMJ 2008.:a2074. Full Citation | Publisher Full Text | Find Related Articles | | Mohammadi H, Klassen RJ, Wan WK A finite element model on effects of impact load and cavitation on fatigue crack propagation in mechanical bileaflet aortic heart valve. [Journal Article, Research Support, Non-U.S. Gov't] Proc Inst Mech Eng [H] 2008 Oct; 222(7):1115-25. Abstract | Full Citation | Publisher Full Text | Find Related Articles | | Galvin A, Brockett C, Williams S, et al. Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads. [Journal Article, Research Support, Non-U.S. Gov't] Proc Inst Mech Eng [H] 2008 Oct; 222(7):1073-80. Abstract | Full Citation | Publisher Full Text | Find Related Articles | | Scheerlinck T, Broos J, Janssen D, et al. Mechanical implications of interfacial defects between femoral hip implants and cement: a finite element analysis of interfacial gaps and interfacial porosity. [Journal Article, Research Support, Non-U.S. Gov't] Proc Inst Mech Eng [H] 2008 Oct; 222(7):1037-47. Abstract | Full Citation | Find Related Articles | | Athanasou NA Peri-implant pathology--relation to implant failure and tumor formation. [Journal Article, Research Support, Non-U.S. Gov't] J Long Term Eff Med Implants 2007; 17(3):193-206. Abstract | Full Citation |  |
|
| | Advertise on this site.
|