Impact of myocardial contrast echocardiography on vascular permeability: comparison of three different contrast agents. Ultrasound in medicine & biology. [Ultrasound Med Biol] Journal article

 
TitleImpact of myocardial contrast echocardiography on vascular permeability: comparison of three different contrast agents.
Author(s)Li P, Armstrong WF, Miller DL 
InstitutionDepartment of Internal Medicine (Cardiology), University of Michigan, Ann Arbor, MI, USA.
SourceUltrasound Med Biol 2004 Jan; 30(1):83-91.
MeSHAlbumins
Animals
Capillary Permeability
Comparative Study
Contrast Media
Dose-Response Relationship, Drug
Echocardiography
Evans Blue
Fluorocarbons
Hydrocarbons, Brominated
Microspheres
Purpura
Rats
Rats, Nude
Research Support, U.S. Gov't, P.H.S.
AbstractMicrovascular permeabilization, petechial hemorrhage and premature ventricular contractions (PVCs) have been demonstrated in an in vivo rat model of myocardial contrast echocardiography (MCE). The purpose of this study was to compare these effects for three US Food and Drug Administration (FDA)-approved ultrasound (US) contrast agents (US CA): Optison, Definity and Imagent. Evans blue dye, an indicator of microvascular permeability, and a contrast agent were injected IV in anesthetized rats suspended in a water bath to mimic scanning depths seen in clinical echocardiology. Diagnostic US B-mode scans with 1:4 end-systolic triggering were performed at 1.7 MHz using a cardiac phased-array scanhead to provide a short axis view of the left ventricle. To elicit readily measurable effects for comparisons, relatively high doses of the agent were used (50 to 500 microL kg(-1) for Optison, 25 to 200 microL kg(-1) for Imagent, 10 to 100 microL kg(-1) for Definity). Microvascular leakage was characterized by the area of Evans blue dye coloration on the hearts and by extraction of the dye from tissue samples. The number of petechia were counted on the epicardial surface of excised hearts. PVCs were counted from ECG traces recorded with the MCE images. Neither evidence of capillary leakage nor PVCs were seen in sham animals. Based on volume dose, Definity MCE produced more microvascular leakage, but there was no apparent difference between the three agents' microvascular damage potential, which increased linearly with dose at low doses, when expressed in terms of the number of stabilized microbubbles. Definity MCE resulted in fewer PVCs than the other agents. The effects increased strongly with peak rarefactional pressure amplitude, with apparent thresholds for petechiae at 0.4 MPa and for PVCs at about 1.0 MPa. These results should be of value for minimizing adverse potential in diagnosis and optimizing efficacy in therapeutic applications.
Languageeng
Pub Type(s)Journal Article
PubMed ID14962612
  
Advertise on this site.