Unbound MEDLINE

Opening-wedge osteotomy, allografting with dual buttress plate fixation for severe genu recurvatum caused by partial growth arrest of the proximal tibial physis: a case report. Journal of orthopaedic trauma. [J Orthop Trauma] Journal article

 
Chen LC, Chan YS, Wang CJ 
Opening-wedge osteotomy, allografting with dual buttress plate fixation for severe genu recurvatum caused by partial growth arrest of the proximal tibial physis: a case report. [Case Reports, Journal Article]
J Orthop Trauma 2004 Jul; 18(6):384-7.


Injuries to the proximal tibial physis are among the least common epiphyseal injuries. We present a case of severe genu recurvatum deformity (45 degrees) with leg length discrepancy (4 cm) following a neglected proximal tibial physeal injury incurred 6 years previously. The 16-year-old patient was successfully treated by open-wedge osteotomy, allograft reconstruction, and dual buttress plate fixation. At 3 years' follow-up, the patient was asymptomatic, fully active with a full range of motion (0 - 140 degrees) of the leg, and equal leg lengths. There were no signs of genu recurvatum clinically.



More from this journalRelated subjects (MeSH)
  