Unbound MEDLINE

Validation of rotation thrombelastography in a model of systemic activation of fibrinolysis and coagulation in humans. Journal of thrombosis and haemostasis : JTH. [J Thromb Haemost] Journal article

 
TitleValidation of rotation thrombelastography in a model of systemic activation of fibrinolysis and coagulation in humans.
Author(s)Spiel AO, Mayr FB, Firbas C, Quehenberger P, Jilma B 
InstitutionDepartment of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria.
SourceJ Thromb Haemost 2006 Feb; 4(2):411-6.
MeSHAdult
Blood Coagulation
Endotoxemia
Fibrinolysis
Humans
In Vitro
Lipopolysaccharides
Male
Models, Biological
Platelet Count
Thrombelastography
von Willebrand Factor
AbstractBACKGROUND: Thrombelastography (TEG) is a whole blood assay to evaluate the viscoelastic properties during blood clot formation and clot lysis. Rotation thrombelastography (e.g. ROTEM) has overcome some of the limitations of classical TEG and is used as a point-of-care device in several clinical settings of coagulation disorders. Endotoxemia leads to systemic activation of the coagulation system and fibrinolysis in humans.
OBJECTIVES: We validated whether ROTEM is sensitive to endotoxin induced, tissue factor-triggered coagulation and fibrinolysis and if its measures correlate with biohumoral markers of coagulation and fibrinolysis.
PATIENTS AND METHODS: Twenty healthy male volunteers participated in this randomized placebo-controlled trial. Volunteers received either 2 ng kg(-1) National Reference Endotoxin or saline.
RESULTS: Endotoxemia significantly shortened ROTEM clotting time (CT) by 36% (CI 0.26-0.46; P < 0.05) with a strong inverse correlation with the peak plasma levels of prothrombin fragments (F(1 + 2)) (r = -0.83, P < 0.05). Additionally, endotoxin infusion enhanced maximal lysis (ML) 3.9-fold (CI: 2.5-5.2) compared with placebo or baseline after 2 h (P < 0.05). Peak ML and peak tissue plasminogen activator (t-PA) values correlated excellently (r = 0.82, P < 0.05). ROTEM parameters clot formation time and maximal clot firmness were not affected by LPS infusion, whereas platelet function analyzer (PFA-100) closure times decreased.
CONCLUSIONS: Rotation thrombelastography (ROTEM) detects systemic changes of in vivo coagulation activation, and importantly it is a point of care device, which is sensitive to changes in fibrinolysis in humans. The ex vivo measures CT and ML correlate very well with established in vivo markers of coagulation activation (F(1 + 2)) and fibrinolysis (t-PA), respectively.
Languageeng
Pub Type(s)Journal Article
Randomized Controlled Trial
Validation Studies
PubMed ID16420574
  
Advertise on this site.