Unbound MEDLINE

Determination of synthetic hormones in animal urine by high-performance liquid chromatography/mass spectrometry. Journal of AOAC International [J AOAC Int] Journal article

 
TitleDetermination of synthetic hormones in animal urine by high-performance liquid chromatography/mass spectrometry.
Author(s)Rúbies A, Cabrera A, Centrich F 
InstitutionLaboratori de l'Agència de Salut Pública de Barcelona, Edifici Peracamps, Avinguda Drassanes 13-15, 08001 Barcelona, Spain. arubies@aspb.es
SourceJ AOAC Int 2007 Mar-Apr; 90(2):626-32.
AbstractA method was developed for the extraction of stanozolol, taleranol, zeranol, hexestrol, dienestrol, ethynylestradiol, diethylstilbestrol, and trenbolone from animal urine. The analytes were extracted from the matrix by enzymatic hydrolysis, solid-phase extraction, and liquid-liquid extraction. Detection and quantitation were performed on a high-performance liquid chromatography system coupled to a triple quadrupole mass spectrometer. The identification criteria met the European Union regulations. Validation of this method established a decision limit between 0.2 and 0.9 microg/L and a detection capability between 0.3 and 1.0 microg/L, depending on the analyte.
Languageeng
Pub Type(s)Journal Article
PubMed ID17474533
  