Unbound MEDLINE

Automated-parameterization of the motor evoked potential and cortical silent period induced by transcranial magnetic stimulation. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology [Clin Neurophysiol] Journal article

 
TitleAutomated-parameterization of the motor evoked potential and cortical silent period induced by transcranial magnetic stimulation.
Author(s)Rábago CA, Lancaster JL, Narayana S, Zhang W, Fox PT 
InstitutionResearch Imaging Center, University of Texas Health Science Center at San Antonio, San Antonio, TX 78229, USA.
SourceClin Neurophysiol 2009 Aug; 120(8):1577-87.
MeSHAdult
Automation
Biophysics
Electric Stimulation
Electromyography
Evoked Potentials, Motor
Female
Humans
Male
Middle Aged
Motor Cortex
Muscle Contraction
Reaction Time
Spreading Cortical Depression
Statistics as Topic
Transcranial Magnetic Stimulation
Young Adult
AbstractOBJECTIVE: To standardize the characterization of motor evoked potential (MEP) and cortical silent period (CSP) recordings elicited with transcranial magnetic stimulation (TMS).
METHODS: A computer-based, automated-parameterization program (APP) was developed and tested which provides a comprehensive set of electromyography (EMG) magnitude and temporal measures. The APP was tested using MEP, CSP, and isolated CSP (iCSP) TMS stimulus-response data from a healthy adult population (N=13).
RESULTS: The APP had the highest internal reliability (Cronbach's alpha=.98) for CSP offset time compared with two prominent automated methods. The immediate post-CSP EMG recovery level was 49% higher than the pre-TMS EMG level. MEP size (peak amplitude, mean amplitude, peak-to-peak amplitude, and area) correlated higher with effective E-field (E(eff)) than other intensity measures (r approximately 0.5 vs. r approximately 0.3) suggesting that E(eff) is better suited for standardizing MEP stimulus-response relationships.
CONCLUSIONS: The APP successfully characterized individual and mean epochs containing MEP, CSP, and iCSP responses. The APP provided common signal and temporal measures consistent with previous studies and novel additional parameters.
SIGNIFICANCE: With the use of the APP modeling method and the E(eff), a standard approach for the analysis and reporting of MEP-CSP complex and iCSP measurements is achievable.
Languageeng
Pub Type(s)Journal Article
Research Support, N.I.H., Extramural
Research Support, Non-U.S. Gov't
PubMed ID19559646
  
Advertise on this site.