Unbound MEDLINE

Revision metacarpophalangeal joint replacement 30 years after primary swanson flexible silicone implant arthroplasty in a rheumatoid patient: a case report. Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand [Hand Surg] Journal article

 
Arai K, Ishikawa H, Murai T, Fujisawa J, Endo N 
Revision metacarpophalangeal joint replacement 30 years after primary swanson flexible silicone implant arthroplasty in a rheumatoid patient: a case report. [Journal Article]
Hand Surg 2009; 14(1):25-9.


We report a case of a patient with rheumatoid arthritis undergoing revision surgery 30 years after primary metacarpophalangeal joint arthroplasty using a Swanson implant. Removal and replacement of the implant were successfully performed, and the patient was satisfied with the revision surgery.