The effects of ultrasound guidance and neurostimulation on the minimum effective anesthetic volume of mepivacaine 1.5% required to block the sciatic nerve using the subgluteal approach. Anesthesia and analgesia [Anesth Analg] Journal article

 
TitleThe effects of ultrasound guidance and neurostimulation on the minimum effective anesthetic volume of mepivacaine 1.5% required to block the sciatic nerve using the subgluteal approach.
Author(s)Danelli G, Ghisi D, Fanelli A, Ortu A, Moschini E, Berti M, Ziegler S, Fanelli G 
InstitutionDepartment of Anesthesia, Intensive Care and Pain Therapy, University Hospital of Parma, 43100 Parma, PR, Italy. gdanelli@ao.pr.i
SourceAnesth Analg 2009 Nov; 109(5):1674-8.
MeSHAdult
Anesthetics, Local
Arthroscopy
Dose-Response Relationship, Drug
Electric Stimulation
Female
Femoral Nerve
Humans
Knee Joint
Male
Mepivacaine
Middle Aged
Nerve Block
Pain Measurement
Pain Threshold
Pain, Postoperative
Sciatic Nerve
Time Factors
Treatment Outcome
Ultrasonography, Interventional
AbstractBACKGROUND: We tested the hypothesis that ultrasound (US) guidance may reduce the minimum effective anesthetic volume (MEAV(50)) of 1.5% mepivacaine required to block the sciatic nerve with a subgluteal approach compared with neurostimulation (NS).
METHODS: After premedication and single-injection femoral nerve block, 60 patients undergoing knee arthroscopy were randomly allocated to receive a sciatic nerve block with either NS (n = 30) or US (n = 30). In the US group, the sciatic nerve was localized between the ischial tuberosity and the greater trochanter. In the NS group, the appropriate muscular response (foot plantar flexion or inversion) was elicited (1.5 mA, 2 Hz, 0.1 ms) and maintained to <or=0.5 mA. The volume of the injected local anesthetic was varied for consecutive patients based on an up-and-down method, according to the response of the previous patient. The initial volume was 12 mL. An independent observer evaluated the occurrence of complete loss of pinprick sensation and motor block: positive or negative responses within 20 min after the injection determined a 2-mL decrease or increase for the next patient, respectively.
RESULTS: The mean MEAV(50) for sciatic nerve block was 12 mL (95% confidence interval [CI], 10-23 mL) in Group US and 19 mL (95% CI, 15-23 mL) in Group NS (P < 0.001). The effective dose in 95% of cases was 14 mL (95% CI, 12-17 mL) in Group US and 29 mL (95% CI, 25-40 mL) in Group NS (P = 0.008).
CONCLUSIONS: US provided a 37% reduction in the MEAV(50) of 1.5% mepivacaine required to block the sciatic nerve compared with NS.