Unbound MEDLINE

In situ fenestration in the aortic arch. Journal of vascular surgery : official publication, the Society for Vascular Surgery [and] International Society for Cardiovascular Surgery, North American Chapter [J Vasc Surg] Journal article

 
Manning BJ, Ivancev K, Harris PL 
In situ fenestration in the aortic arch. [JOURNAL ARTICLE]
J Vasc Surg 2009 Oct 29.


In situ fenestration of aortic stent grafts has the potential to allow for continued perfusion of supra-aortic trunks, without the need for extra-anatomic bypass, and without the need for custom-made devices. Angulation of the target vessel relative to the arch is an obstacle to success with this technique. In this report, we describe a case of successful in situ fenestration of the left subclavian artery (LSA) in a patient with an aortic arch aneurysm, treated with an endovascular stent graft. We outline a novel technique using through and through wire access and a pre-curved semi-rigid sheath, which allows successful access to the lumen of the aortic stent graft, despite an acute angle at the take-off of the LSA.