Unbound MEDLINE

Combined insulin pump therapy with real-time continuous glucose monitoring significantly improves glycemic control compared to multiple daily injection therapy in pump naïve patients with type 1 diabetes; single center pilot study experience. Journal of diabetes science and technology (Online) [J Diabetes Sci Technol] Journal article

 
TitleCombined insulin pump therapy with real-time continuous glucose monitoring significantly improves glycemic control compared to multiple daily injection therapy in pump naïve patients with type 1 diabetes; single center pilot study experience.
Author(s)Lee SW, Sweeney T, Clausen D, Kolbach C, Hassen A, Firek A, Brinegar C, Petrofsky J 
InstitutionLoma Linda University School of Medicine, Diabetes Treatment Center , Loma Linda, California.
SourceJ Diabetes Sci Technol 2007 May; 1(3):400-4.
AbstractOBJECTIVES: This study assessed the safety and clinical effectiveness of the training protocol for initiating insulin pump therapy with real-time continuous glucose monitoring (MiniMed Paradigm REAL-Time System) in a stepwise approach on pump naive subjects with type 1 diabetes compared to a control group who remained on multiple daily injection (MDI) therapy.
METHODS: This was a 15-week treat-to-target pilot study of 16 adult subjects (n = 50% male, age 45.9 +/- 16 years) with type 1 diabetes (duration of diabetes 21.9 +/- 11 years) on MDI therapy with hemoglobin A1c levels at or above 7.5% at baseline. Subjects were randomized to either the study arm (using a combined insulin pump and real-time continuous glucose monitoring system) or the control arm [which continued on MDI therapy with self-monitored blood glucose (SMBG) only]. All subjects dosed insulin according to results of SMBG by finger stick and uploaded data into the CareLink data management software.
RESULTS: Significant improvements in glycemic control were observed from baseline in both study groups-study arm: pre-A1c 9.45 +/- 0.55 and post-A1c 7.4 +/- 0.66 (p = 0.00037); control arm: pre-A1c 8.58 +/- 1.30 and post-A1c 7.5 +/-1.01 (p = 0.04). Both arms had no incidence of severe hypoglycemia.
CONCLUSION: In this pilot study, the Paradigm REAL-Time System was initiated safely and effectively in type 1 diabetes patients who were pump naïve using a stepwise educational protocol.
Languageeng
Pub Type(s)Journal Article
PubMed ID19885096
  