| Unbound MEDLINE results for: | Bookmark this site | | Articles related to 18623616 [Unique ID], provided by the PubMed system | |
| |
|
| | 1 - 10 of 102 journal articles in the PubMed database | Email to a friend | | |
| Dumont J, Fortier G Behavior of glucose oxidase immobilized in various electropolymerized thin films. [Journal Article] Biotechnol Bioeng 1996 Mar 5; 49(5):544-52. Abstract | Full Citation | Find Related Articles | | Almeida NF, Beckman EJ, Ataai MM Immobilization of glucose oxidase in thin polypyrrole films: Influence of polymerization conditions and film thickness on the activity and stability of the immobilized enzyme. [Journal Article] Biotechnol Bioeng 1993 Nov 5; 42(9):1037-45. Abstract | Full Citation | Publisher Full Text | Find Related Articles | | Fortier G, Bélanger D Characterization of the biochemical behavior of glucose oxidase entrapped in a polypyrrole film. [Journal Article] Biotechnol Bioeng 1991 Apr 15; 37(9):854-8. Abstract | Full Citation | | Malitesta C, Palmisano F, Torsi L, et al. Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film. [Journal Article, Research Support, Non-U.S. Gov't ] Anal Chem 1990 Dec 15; 62(24):2735-40. Abstract | Full Citation | Find Related Articles | | Danilich MJ, Kottke-Marchant K, Anderson JM, et al. The immobilization of glucose oxidase onto radio-frequency plasma-modified poly(etherurethaneurea). [Journal Article, Research Support, U.S. Gov't, P.H.S. ] J Biomater Sci Polym Ed 1992; 3(3):195-216. Abstract | Full Citation | Find Related Articles | | Li J, Lin X Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode. [JOURNAL ARTICLE] Biosens Bioelectron 2007 Jan 8. Abstract | Full Citation | | Onda M, Ariga K, Kunitake T Activity and stability of glucose oxidase in molecular films assembled alternately with polyions. [Journal Article] J Biosci Bioeng 1999; 87(1):69-75. Abstract | Full Citation | Publisher Full Text | Find Related Articles | | Fortier G, Brassard E, Bélanger D Optimization of a polypyrrole glucose oxidase biosensor. [Journal Article] Biosens Bioelectron 1990; 5(6):473-90. Abstract | Full Citation | Publisher Full Text | Find Related Articles | | Li ZF, Kang ET, Neoh KG, et al. Covalent immobilization of glucose oxidase on the surface of polyaniline films graft copolymerized with acrylic acid. [Journal Article] Biomaterials 1998 Jan-Feb; 19(1-3):45-53. Abstract | Full Citation | Publisher Full Text | Find Related Articles |  |
|
| | Advertise on this site.
|