| Unbound MEDLINE results for: | Bookmark this site | | Articles related to 18784515 [Unique ID], provided by the PubMed system | |
| |
|
| | 1 - 10 of 105 journal articles in the PubMed database | Email to a friend | | |
| Biggs PJ, Styczynski JR DO ANGLES OF OBLIQUITY APPLY TO 30 degrees SCATTERED RADIATION FROM MEGAVOLTAGE BEAMS? [Journal Article] Health Phys 2008 Oct; 95(4):425-32. Abstract | Full Citation | Publisher Full Text | Find Related Articles | | Jaradat AK, Biggs PJ TENTH VALUE LAYERS FOR 60Co GAMMA RAYS AND FOR 4, 6, 10, 15, AND 18 MV X RAYS IN CONCRETE FOR BEAMS OF CONE ANGLES BETWEEN 0 degrees AND 14 degrees CALCULATED BY MONTE CARLO SIMULATION. [JOURNAL ARTICLE] Health Phys 2007 May; 92(5):456-463. Abstract | Full Citation | Find Related Articles | | Nogueira IP, Biggs PJ Measurement of TVLs in lead for 4, 6 and 10 MV bremsstrahlung x-ray beams at scattering angles between 30 degrees and 135 degrees. [Journal Article] Health Phys 2002 Aug; 83(2):255-60. Abstract | Full Citation | Find Related Articles | | Biggs PJ Obliquity factors for 60 Co and 4, 10, and 18 MV x rays for concrete, steel, and lead and angles of incidence between 0 and 70 degrees. [Journal Article] Health Phys 1996 Apr; 70(4):527-36. Abstract | Full Citation | Publisher Full Text | Find Related Articles | | Shobe J, Rodgers JE, Taylor PL Scattered fractions of dose from 6,10,18, and 25 MV linear accelerator x rays in radiotherapy facilities. [Journal Article] Health Phys 1999 Jan; 76(1):27-35. Abstract | Full Citation | Publisher Full Text | Find Related Articles | | Rodgers JE Analysis of tenth-value-layers for common shielding materials for a robotically mounted stereotactic radiosurgery machine. [Journal Article] Health Phys 2007 Apr; 92(4):379-86. Abstract | Full Citation | Publisher Full Text | Find Related Articles | | Taylor PL, Rodgers JE, Shobe J Scatter fractions from linear accelerators with x-ray energies from 6 to 24 MV. [Journal Article] Med Phys 1999 Aug; 26(8):1442-6. Abstract | Full Citation | Find Related Articles | | Kato H [Effective dose transmission of diagnostic X-rays through concrete and lead shields] [Journal Article] Nippon Hoshasen Gijutsu Gakkai Zasshi 2003 Aug; 59(8):965-75. Abstract | Full Citation | Find Related Articles | | Fondevila D, Arbiser S, Sansogne R, et al. Maximum dose angle for oblique incidence on primary beam protective barriers in the design of medical radiation therapy facilities. [Journal Article] Med Phys 2008 May; 35(5):1816-9. Abstract | Full Citation | Find Related Articles |  |
|
| | Enter www.unboundmedicine.com/medline in your iPhone browser or View our Unbound MEDLINE iPhone demo Advertise on this site.
|