Unbound MEDLINE

Articles related to 18801579 journal articles from PubMed MEDLINE database

Unbound MEDLINE results for:Bookmark this site
Articles related to 18801579 [Unique ID], provided by the PubMed system
1 - 10 of 113 journal articles in the PubMed databaseEmail to a friend    
 
Sandhu SS, Chattopadhyay S, Amariotakis GA, et al. 
The Accuracy of Continued Clinical Use of Goldmann Applanation Tonometers with Known Calibration Errors. [JOURNAL ARTICLE]
Ophthalmology 2008 Sep 16.
Abstract | Full Citation | Publisher Full Text | Find Related Articles 
Choudhari NS, George R, Baskaran M, et al. 
Measurement of Goldmann Applanation Tonometer Calibration Error. [JOURNAL ARTICLE]
Ophthalmology 2008 Aug 15.
Abstract | Full Citation | Publisher Full Text | Find Related Articles 
Sandhu SS, Chattopadhyay S, Birch MK, et al. 
Frequency of goldmann applanation tonometer calibration error checks. [Journal Article]
J Glaucoma 2005 Jun; 14(3):215-8.
Abstract | Full Citation | Publisher Full Text | Find Related Articles 
Almubrad TM, Ogbuehi KC 
The effect of repeated applanation on subsequent IOP measurements. [JOURNAL ARTICLE]
Clin Exp Optom 2008 Jul 21.
Abstract | Full Citation | Find Related Articles 
Detry-Morel M, Jamart J, Detry MB, et al. 
[Clinical evaluation of the Pascal dynamic contour tonometer] [English Abstract, Journal Article]
J Fr Ophtalmol 2007 Mar; 30(3):260-70.
Abstract | Full Citation | Find Related Articles 
Patikulsila D, Taweemankongsab S, Ngamtipakorn S 
Comparison of intraocular pressure measured by non-contact air puff versus Goldmann applanation tonometers in gas-filled vitrectomized eyes. [Journal Article]
J Med Assoc Thai 2003 May; 86(5):467-72.
Abstract | Full Citation | Find Related Articles 
Alvarez TL, Gollance SA, Thomas GA, et al. 
The Proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice. [Evaluation Studies, Journal Article, Multicenter Study]
Ophthalmology 2004 Jun; 111(6):1077-85.
Abstract | Full Citation | Publisher Full Text | Find Related Articles 
Chuo JY, Mikelberg FS 
Calibration errors of Goldmann tonometers in a tertiary eye care centre. [Journal Article]
Can J Ophthalmol 2007 Oct; 42(5):712-4.
Abstract | Full Citation | Publisher Full Text | Find Related Articles 
Fernandes P, Díaz-Rey JA, Queirós A, et al. 
Comparison of the ICare rebound tonometer with the Goldmann tonometer in a normal population. [Evaluation Studies, Journal Article]
Ophthalmic Physiol Opt 2005 Sep; 25(5):436-40.
Abstract | Full Citation | Publisher Full Text | Find Related Articles 
New Search Next Results
  

Enter
www.unboundmedicine.com/medline
in your iPhone browser
or View our
Unbound MEDLINE
iPhone demo


Advertise on this site.