Unbound MEDLINE

Articles related to 18812648 journal articles from PubMed MEDLINE database

Unbound MEDLINE results for:Bookmark this site
Articles related to 18812648 [Unique ID], provided by the PubMed system
1 - 10 of 101 journal articles in the PubMed databaseEmail to a friend    
 
Minarik D, Sjögreen Gleisner K, Ljungberg M 
Evaluation of quantitative (90)Y SPECT based on experimental phantom studies. [JOURNAL ARTICLE]
Phys Med Biol 2008 Sep 24; 53(20):5689-5703.
Abstract | Full Citation | Find Related Articles 
He B, Du Y, Song X, et al. 
A Monte Carlo and physical phantom evaluation of quantitative In-111 SPECT. [Evaluation Studies, Journal Article]
Phys Med Biol 2005 Sep 7; 50(17):4169-85.
Abstract | Full Citation | Publisher Full Text | Find Related Articles 
Ouyang J, El Fakhri G, Moore SC 
Fast Monte Carlo based joint iterative reconstruction for simultaneous 99mtc/ 123I SPECT imaging. [Journal Article, Research Support, N.I.H., Extramural]
Med Phys 2007 Aug; 34(8):3263-72.
Abstract | Full Citation | Find Related Articles 
Seo Y, Wong KH, Sun M, et al. 
Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system. [Clinical Trial, Journal Article, Validation Studies]
J Nucl Med 2005 May; 46(5):868-77.
Abstract | Full Citation | Publisher Full Text | Find Related Articles 
Du Y, Tsui BM, Frey EC 
Model-based compensation for quantitative 123I brain SPECT imaging. [Journal Article]
Phys Med Biol 2006 Mar 7; 51(5):1269-82.
Abstract | Full Citation | Publisher Full Text | Find Related Articles 
Yokoi T, Shinohara H, Onishi H 
Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: a simulation study. [Evaluation Studies, Journal Article]
Ann Nucl Med 2002 Feb; 16(1):11-8.
Abstract | Full Citation | Find Related Articles 
He B, Frey EC 
Comparison of conventional, model-based quantitative planar, and quantitative SPECT image processing methods for organ activity estimation using In-111 agents. [Journal Article]
Phys Med Biol 2006 Aug 21; 51(16):3967-81.
Abstract | Full Citation | Publisher Full Text | Find Related Articles 
LaCroix KJ, Tsui BM, Hasegawa BH 
A comparison of 180 degrees and 360 degrees acquisition for attenuation-compensated thallium-201 SPECT images. [Journal Article]
J Nucl Med 1998 Mar; 39(3):562-74.
Abstract | Full Citation | Find Related Articles 
de Wit TC, Xiao J, Nijsen JF, et al. 
Hybrid scatter correction applied to quantitative holmium-166 SPECT. [JOURNAL ARTICLE]
Phys Med Biol 2006 Oct 7; 51(19):4773-4787.
Abstract | Full Citation | Publisher Full Text | Find Related Articles 
New Search Next Results
  
Medical References for Treo, iPhone or Blackberry!

Advertise on this site.