(adaptometer)
96 results
  • The field-ready tea-box adaptometer: colonial nutrition science and/in imperial economies in Malawi. [Journal Article]
    Med Hist. 2025 May 15; :1-16. [Online ahead of print]Biruk CMH
  • In the late 1930s, children in three Malawian villages were subjected to a peculiar test for vitamin A deficiency devised by Dr. Benjamin Platt, director of the Nyasaland Nutrition Survey and a leading colonial nutrition scientist. Platt constructed a makeshift adaptometer, appropriate for field conditions, that could be placed over a subject's head to measure retinal adaptation to light. He buil…
  • A review of portable quantitative and semi-quantitative devices for measurement of vitamin A in biological samples. [Review]
    Curr Res Biotechnol. 2022; 4:253-274.Huey SL, Krisher JT, … Mehta SCR
  • CONCLUSIONS: The iCheck Fluoro and iCheck Carotene are commercially available for use and are acceptable for measuring vitamin A in blood and milk samples, according to the available validation data. Many of the other identified devices, including other portable fluorometers, photometers, immunoassays, microfluidics-based devices, and dark adaptometers, were proofs of concept and not yet commercially available. Furthermore, none of these other devices included manufacturer-described device performance criteria to compare with descriptions from experimental studies. Several gaps remain, including studies comparing the other portable devices against a reference standard, particularly for functional indicators of vitamin A status/deficiency; available manufacturer-reported device performance criteria against which to compare future results of investigations; and more comprehensive reporting of validation metrics including sensitivity, specificity, precision, and Bland-Altman analysis.
  • Evaluation of Cone- and Rod-Mediated Parameters in Dark Adaptation Testing as Outcome Measures in Age-Related Macular Degeneration. [Journal Article]
    Ophthalmol Retina. 2022 Dec; 6(12):1173-1184.Hess K, de Silva T, … Cukras CAOR
  • CONCLUSIONS: Age-related macular degeneration severity and RPD presence are each associated with large differences in multiple DA curve parameters. In addition, substantial differences in some parameters occur with age, even accounting for AMD severity and RPD status. This supports the 2-hit hypothesis of age and disease status on DA (and perhaps AMD pathophysiology itself). Of the DA parameters, RIT has the highest retest reliability, closest correlation with AMD severity and RPD, and largest longitudinal changes. This underscores the suitability of RIT as an outcome measure in clinical trials. The cone plateau increases only in advanced stages of kinetic rod dysfunction, indicating rod dysfunction preceding cone dysfunction and degeneration in the temporal sequence of pathology in AMD.
  • Functionally validated imaging endpoints in the Alabama study on early age-related macular degeneration 2 (ALSTAR2): design and methods. [Journal Article]
    BMC Ophthalmol. 2020 May 19; 20(1):196.Curcio CA, McGwin G, … Owsley CBO
  • CONCLUSIONS: A major barrier to developing treatments and prevention strategies for early AMD is a limited understanding of the temporal interrelationships among structural and functional characteristics while transitioning from aging to early AMD. ALSTAR2 will enable the development of functionally valid, structural biomarkers for early AMD, suitable for use in forthcoming clinical trials as endpoint/outcome measures. The comprehensive dataset will also allow hypothesis-testing for mechanisms that underlie the transition from aging to AMD, one of which is a newly developed Center-Surround model of cone resilience and rod vulnerability.
  • Correlation of retinal vascular perfusion density with dark adaptation in diabetic retinopathy. [Journal Article]
    Graefes Arch Clin Exp Ophthalmol. 2019 Jul; 257(7):1401-1410.Hsiao CC, Hsu HM, … Yang CHGA
  • CONCLUSIONS: The vascular density of the macula could be assessed by OCTA and the functional change in the outer retina could be measured non-invasively by DA. The severity of decreasing vascular density and prolongation of DA are proportional to progression of DR. Decreased deep retinal vascular perfusion density and impaired DA response are correlated and show a negative trend according to the severity of DR.
  • Decreased Visual Function Scores on a Low Luminance Questionnaire Is Associated with Impaired Dark Adaptation. [Journal Article]
    Ophthalmology. 2017 Sep; 124(9):1332-1339.Yazdanie M, Alvarez J, … Cukras CO
  • CONCLUSIONS: This cross-sectional analysis demonstrates associations of patient-reported functional deficits, as assessed on the LLQ, with both reduced DA and reduced choroidal thickness, in a population of older adults with varying degrees of AMD severity and good visual acuity in at least 1 eye. These analyses suggest that local functional measurements of DA testing (RIT) and choroidal thickness are associated with patient-reported functional deficits.
  • The Tuebingen Scotopic Threshold Test (TSTT). [Journal Article]
    IEEE J Biomed Health Inform. 2018 Mar; 22(2):607-610.Strasser T, Langrova H, … Zobor DIJ
  • Measurement of the dark-adaptation threshold plays a key role in the diagnosis and estimation of disease progression of many retinal disorders. Determining the threshold is, however, difficult to perform in young children. We present here a prototype for a dark adaptometer, the Tuebingen Scotopic Threshold Test aimed to ease measurement of photoreceptor thresholds in young subjects. The device co…
  • Recent advances in the dark adaptation investigations. [Review]
    Int J Ophthalmol. 2015; 8(6):1245-52.Yang GQ, Chen T, … Zhang ZMIJ
  • Dark adaptation is a highly sensitive neural function and may be the first symptom of many status including the physiologic and pathologic entity, suggesting that it could be instrumental for diagnose. However, shortcomings such as the lack of standardized parameters, the long duration of examination, and subjective randomness would substantially impede the use of dark adaptation in clinical work…