- Computing leaky circumferential and axial guided wave dispersion curves with spectral collocation. [Journal Article]J Acoust Soc Am. 2026 Oct 01; 160(4):3464-3476.JA
- Leaky waves propagating around the circumference or along the axis of immersed or buried cylindrical waveguides play a prominent role in the guided wave non-destructive evaluation inspection of submerged or embedded structures; a thorough understanding of the complex characteristics of leaky waves in such systems is essential for a range of applications. In this contribution, we apply a spectral …
- Publisher Full Text (DOI)
- Screening-based prevalence and axis distribution of astigmatism among children and adolescents in Lintong District, Xi'an: a large-scale school-based cross-sectional study. [Journal Article]
- CONCLUSIONS: Astigmatism was common in this large district school screening dataset and differed by school stage, axis type, and refractive-status category. The findings may help local screening programs plan re-examination and referral pathways, but they should not be interpreted as cycloplegic clinical diagnoses or as evidence of temporal progression or causality.
- PMC Free PDF
- Structure-Constrained RGB-D Joint Estimation of Robot Pose and 3D Damage Location in Weakly Textured Pipelines. [Journal Article]
- Weakly textured closed pipelines-including energy and buried drainage conduits-require timely inspection of cracks, corrosion, joints and related defects. Weak illumination, sparse texture and repetitive cylindrical geometry degrade visual odometry and RGB-D SLAM, especially along the pipe axis, while image-level detectors rarely provide the axial distance, circumferential angle and pipe-frame 3D…
- PMC Free PDF
- Thermomechanical Responses of Cryogenic Composite Pressure Vessels with Different Dome Aspect Ratios. [Journal Article]
- Large-scale metal-lined composite overwrapped pressure vessels are promising for cryogenic liquid oxygen storage, but their response is governed by the interaction among dome geometry, thermal mismatch and internal pressure. This study investigates the influence of dome aspect ratio (DAR), defined as the ratio of the major to minor semi-axis of an ellipsoidal dome, on vessel thermomechanical beha…
- PMC Free PDF
- Retrospective Assessment of LLM Decision-Making for IOL Power Selection in Cataract Surgery in Comparison with Surgeon Performance. [Journal Article]
- Objectives: To evaluate a general-purpose large language model (LLM)'s ability to perform surgeon-level decision-making in choosing an intraocular lens (IOL) power when provided the same preoperative data. Methods: This study included 293 eyes (174 patients) that underwent monofocal or toric cataract surgery performed by a single surgeon. GPT-5.2 analyzed the same biometric printouts, topographic…
- PMC Free PDF
- A Safe Medial Column Screw Strategy for Transcondylar Humerus Fractures in the Elderly: CT-Based Analysis of Screw Diameter and Insertion Trajectory. [Journal Article]J Shoulder Elbow Surg. 2026 Oct 01. [Online ahead of print]JS
- CONCLUSIONS: The medial column anatomically accommodated a diameter of at least 5.0 mm in most elderly patients. An approximately 5.0-mm MCS may therefore represent a candidate diameter when individual anatomy permits, although insertion trajectories require patient-specific adjustment and biomechanical validation is needed.
- Publisher Full Text (DOI)
- Rotational stability and visual outcomes of toric implantable collamer lenses in eyes with horizontal and non-horizontal implanting orientation: an observational study. [Journal Article]
- CONCLUSIONS: Non-horizontal EVO-TICL implantation yields rotational stability, safety and efficacy comparable to horizontal placement over 3 months, with small mean rotations and tight refractive predictability. These findings support non-horizontal orientation as a viable alternative when anatomy or vault optimization warrants it.
- PMC Free PDF
- Preoperative Corneal Astigmatic Direction is Associated with Stromal Mechanical Anisotropy in SMILE-Derived Lenticules. [Journal Article]
- CONCLUSIONS: Preoperative corneal astigmatic direction may be a clinically measurable stratification variable for interpreting fixed-axis stromal mechanical anisotropy measurements in SMILE-derived lenticules. These findings support incorporating directional clinical phenotypes into corneal biomechanical research and patient-specific modeling, while requiring validation in larger independent samples.
- PMC Free PDF
- Targeting ALDH2 with Alda-1 to reverse cisplatin resistance in lung adenocarcinoma. [Journal Article]
- CONCLUSIONS: ALDH2 represents a potential prognostic biomarker associated with favorable outcomes in LUAD, particularly in patients receiving chemotherapy. Its activation via Alda-1 overcomes cisplatin resistance by targeting the PKC-ζ/MDR1 axis, presenting a novel therapeutic strategy.
- Publisher Full Text (DOI)
- Analysis of astigmatism type influence on in vivo corneal biomechanical measurements. [Journal Article]
- CONCLUSIONS: In vivo biomechanical measurements were influenced by different astigmatism types. SP-A1 was the primary outcome and differed significantly among astigmatism types. Power vector analysis showed that a greater WTR component was correlated with higher SP-A1, Integrated Radius, and HC dArc length, and lower Radius. Astigmatism axis type and cylinder power could be considered when interpreting in vivo biomechanical measurements to improve the precision of corneal biomechanical evaluation.
- PMC Free PDF
- Stability, Safety, and Efficacy of WaveLight Plus InnovEyes Ray-Tracing-Guided LASIK in Myopia and Myopic Astigmatism: A One-Year Prospective Study. [Journal Article]Am J Ophthalmol. 2026 Sep 10; 292:634-644. [Online ahead of print]AJ
- CONCLUSIONS: WL Plus LASIK demonstrated excellent efficacy, safety, refractive accuracy and stability at 1 year. The platform provided precise astigmatic correction with minimal residual error and high axis alignment, including in eyes with higher astigmatism, indicating that ray-tracing-guided LASIK was an effective and predictable option for the correction of myopia and myopic astigmatism.
- Publisher Full Text (DOI)
- A contactless heat engine driven by nonreciprocal fluctuation-induced torques. [Journal Article]J Chem Phys. 2026 Sep 14; 165(10).JC
- We describe a contactless heat engine in which quantum and thermal electromagnetic fluctuations act as the working medium. The setup consists of two concentric cylinders held at different temperatures. The inner cylinder stably levitates within the outer one due to repulsive nonequilibrium Casimir forces. The chirality of the setup is broken by using nonreciprocal dielectric materials, akin to ap…
- Publisher Full Text (DOI)
- Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation. [Journal Article]
- CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (- 2.00 to - 3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV: - 0.35 ± 0.43 D × 91°, CI > 1), while SMILE/KLEx showed relative undercorrection (vector mean DV: - 0.21 ± 0.53 D × 12°, CI < 1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.
- Publisher Full Text (DOI)
- Microbeam SAXS Reveals Flow-Induced Nanostructural Heterogeneity and Tilted Domains in 3D-Printed Block Copolymers. [Journal Article]
- The nozzle geometries associated with extrusion-based 3D printing impart significant spatial heterogeneities in both the type (shear vs extension) and rate of the flows applied during extrusion. For polymeric and nanostructured inks, these heterogeneous flow histories influence the underlying structure at the nano- to microscale. We previously demonstrated that HOT-DIW 3D printing can orient the …
- PMC Free PDF
- Enhanced predictability and axis precision of SMILE Pro, a retrospective analysis of myopic astigmatism correction. [Journal Article]
- CONCLUSIONS: SMILE Pro using the VISUMAX 800 femtosecond laser provides safe and predictable correction of myopic astigmatism with good axis alignment. However, the observed undercorrection in higher cylinders suggests that further optimization of astigmatic nomograms may improve refractive accuracy.
- PMC Free PDF