Exogenous progestins are an effective tool for hormonal contraception and family planning. Progestins may be delivered as oral pills, intramuscular or subcutaneous injections, vaginal rings, or intrauterine devices. Drug concentrations may vary based on the route and duration of delivery. Measurement of synthetic steroids in blood plasma can aid in determination of product adherence, evaluation of drug-drug interactions, and investigation of unintended pregnancies.

METHODS

Drug-free K2EDTA plasma was spiked with the synthetic steroids etonogestrel (ETO), levonorgestrel (LNG), medroxyprogesterone acetate (MPA), and norethisterone (NET). Plasma was combined with isotopically labeled internal standards, and drugs were extracted via liquid-liquid extraction. Samples were then subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. The method was validated in accordance with regulatory recommendations. The assay was evaluated in a cohort of remnant plasma samples in individuals using one of the aforementioned progestins.

RESULTS

The analytical measuring range for ETO, MPA, and NET was 20-10,000 pg/mL; the primary linearity for LNG was 20-20,000 pg/mL. The method showed acceptable precision and accuracy for all progestins. Stability was established for 72 h with room temperature storage and through 3 freeze-thaw cycles. All analytes were stable in whole blood incubated at room temperature for 25 h, and at 40°C and 100% humidity for 2 h. Ion suppression was observed for all analytes spiked in plasma; average ion suppression was 31.6%, 66.6%, 32.1% and 41.2% for ETO, LNG, MPA, and NET, respectively. However, internal standards showed comparable ion suppression, and relative matrix effects were minimal. ETO, LNG, MPA, and NET could also be quantified accurately in K3EDTA plasma and serum. Progestins were successfully measured in remnant samples from individuals using hormonal contraceptives.

CONCLUSIONS

A multiplexed LC-MS/MS assay for the quantification of ETO, LNG, MPA, and NET has been developed and validated. The assay met acceptable performance characteristics and may be used in downstream studies to evaluate progestin pharmacology.

Links

PMC Free PDF

Authors+Show Affiliations

Knezevic CEDepartment of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA; Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Parsons TLDepartment of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Gollings RDepartment of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Pandey ADepartment of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Marzinke MADepartment of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA; Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD, USA. Electronic address: Mmarzin1@jhmi.edu.

MeSH

FemaleHumansContraceptive AgentsProgestinsChromatography, LiquidTandem Mass SpectrometryEdetic AcidLevonorgestrelSteroidsMedroxyprogesterone AcetatePlasma

Pub Type(s)

Journal Article

Language

eng

PubMed ID

36924631
© 2000–2026 Unbound Medicine, Inc. All rights reserved
All content is protected by copyright and may not be used for AI model training or other unauthorized purposes.