Abstract

This work presents a simple method for obtaining homogeneous sample surfaces in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) for the automated analysis of peptides and proteins. The sample preparation method is based on applying the sample/matrix mixture onto a pre-deposited highly diluted matrix spot. The pre-deposited crystals act as seeds for the new sample containing crystals which become much smaller in size and more evenly distributed than with conventional methods. This 'seed-layer' method was developed, optimised and compared with the dried-droplet method using peptides and proteins in the 1000-20,000 Da range. The seed-layer method increases the surface homogeneity, spot to spot reproducibility and sample washability as compared with the commonly used dried-droplet method. This methodology is applicable to alpha-cyanohydroxycinnamic acid, sinapinic acid and ferulic acid, which all form homogeneous crystal surfaces. Within-spot variation and between-spot variation was investigated using statistics at a 95% confidence level (n = 36). The statistical values were generated from more than 5000 data points collected from 500 spectra. More than 90% of the sample locations results in high intensity spectra with relatively low standard deviations (RSDs). Typically obtained data showed an RSD of 19-35% within a sample spot as well as in-between spots for proteins, and an RSD of < or = 50% for peptides. Linear calibration curves were obtained within one order of magnitude using internal calibration with a point-RSD of 3% (n = 10). The sample homogeneity allows mass spectra (average of 16 laser shots) to be obtained on each individual sample within 15 sec, whereby a 100 spot target plate can be run in 25 min. High density target plates using the seed-layer method were prepared by spotting approximately 100 picoliter droplets onto the target, resulting in sample spots < or = 500 microns in diameter using a flow-through piezo-electric micro-dispenser. By using this automated sample preparation step lower standard deviations are obtained in comparison to manually prepared samples.

Authors+Show Affiliations

Department of Analytical Chemistry, Lund University, Sweden.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

10209870

Citation

Onnerfjord, P, et al. "Homogeneous Sample Preparation for Automated High Throughput Analysis With Matrix-assisted Laser Desorption/ionisation Time-of-flight Mass Spectrometry." Rapid Communications in Mass Spectrometry : RCM, vol. 13, no. 5, 1999, pp. 315-22.
Onnerfjord P, Ekström S, Bergquist J, et al. Homogeneous sample preparation for automated high throughput analysis with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. Rapid Commun Mass Spectrom. 1999;13(5):315-22.
Onnerfjord, P., Ekström, S., Bergquist, J., Nilsson, J., Laurell, T., & Marko-Varga, G. (1999). Homogeneous sample preparation for automated high throughput analysis with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. Rapid Communications in Mass Spectrometry : RCM, 13(5), 315-22.
Onnerfjord P, et al. Homogeneous Sample Preparation for Automated High Throughput Analysis With Matrix-assisted Laser Desorption/ionisation Time-of-flight Mass Spectrometry. Rapid Commun Mass Spectrom. 1999;13(5):315-22. PubMed PMID: 10209870.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Homogeneous sample preparation for automated high throughput analysis with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. AU - Onnerfjord,P, AU - Ekström,S, AU - Bergquist,J, AU - Nilsson,J, AU - Laurell,T, AU - Marko-Varga,G, PY - 1999/4/21/pubmed PY - 2000/6/20/medline PY - 1999/4/21/entrez SP - 315 EP - 22 JF - Rapid communications in mass spectrometry : RCM JO - Rapid Commun Mass Spectrom VL - 13 IS - 5 N2 - This work presents a simple method for obtaining homogeneous sample surfaces in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) for the automated analysis of peptides and proteins. The sample preparation method is based on applying the sample/matrix mixture onto a pre-deposited highly diluted matrix spot. The pre-deposited crystals act as seeds for the new sample containing crystals which become much smaller in size and more evenly distributed than with conventional methods. This 'seed-layer' method was developed, optimised and compared with the dried-droplet method using peptides and proteins in the 1000-20,000 Da range. The seed-layer method increases the surface homogeneity, spot to spot reproducibility and sample washability as compared with the commonly used dried-droplet method. This methodology is applicable to alpha-cyanohydroxycinnamic acid, sinapinic acid and ferulic acid, which all form homogeneous crystal surfaces. Within-spot variation and between-spot variation was investigated using statistics at a 95% confidence level (n = 36). The statistical values were generated from more than 5000 data points collected from 500 spectra. More than 90% of the sample locations results in high intensity spectra with relatively low standard deviations (RSDs). Typically obtained data showed an RSD of 19-35% within a sample spot as well as in-between spots for proteins, and an RSD of < or = 50% for peptides. Linear calibration curves were obtained within one order of magnitude using internal calibration with a point-RSD of 3% (n = 10). The sample homogeneity allows mass spectra (average of 16 laser shots) to be obtained on each individual sample within 15 sec, whereby a 100 spot target plate can be run in 25 min. High density target plates using the seed-layer method were prepared by spotting approximately 100 picoliter droplets onto the target, resulting in sample spots < or = 500 microns in diameter using a flow-through piezo-electric micro-dispenser. By using this automated sample preparation step lower standard deviations are obtained in comparison to manually prepared samples. SN - 0951-4198 UR - https://www.unboundmedicine.com/medline/citation/10209870/Homogeneous_sample_preparation_for_automated_high_throughput_analysis_with_matrix_assisted_laser_desorption/ionisation_time_of_flight_mass_spectrometry_ L2 - https://doi.org/10.1002/(SICI)1097-0231(19990315)13:5&lt;315::AID-RCM483&gt;3.0.CO;2-C DB - PRIME DP - Unbound Medicine ER -