[Pulsatile microdialysis method with glucose sensor system].
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 1998 Sep; 15(3):298-302.SW

Abstract

To develop a miniature subcutaneous glucose sensor system, to simplify calibration procedure before or after glucose monitor, and to improve its temperature characteristics, a pulsatile micropump and the microdialysis technique were used. The experiments of glucose recovery in 5.5 mM and 10 mM G.S. and the temperature experiment from 20 degrees C to 40 degrees C were conducted. The results showed that glucose recovery was (97 +/- 2)%, the current values of glucose sensor varied with temperature, but the temperature parameter was only 3.4%. These indicate that the glucose sensor system is miniature and the calibration procedure is simple. Because of its modified temperature characterisic, it is useful to monitor the blood glucose of feverish diabetics.

Authors+Show Affiliations

Department of Internal Medicine, 2nd Affiliated Hospital Zhejiang Medical University, Hangzhou 310009.No affiliation info availableNo affiliation info available

Pub Type(s)

English Abstract
Journal Article

Language

chi

PubMed ID

12553258

Citation

Liang, H, et al. "[Pulsatile Microdialysis Method With Glucose Sensor System]." Sheng Wu Yi Xue Gong Cheng Xue Za Zhi = Journal of Biomedical Engineering = Shengwu Yixue Gongchengxue Zazhi, vol. 15, no. 3, 1998, pp. 298-302.
Liang H, Zhao Y, Song Z. [Pulsatile microdialysis method with glucose sensor system]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 1998;15(3):298-302.
Liang, H., Zhao, Y., & Song, Z. (1998). [Pulsatile microdialysis method with glucose sensor system]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi = Journal of Biomedical Engineering = Shengwu Yixue Gongchengxue Zazhi, 15(3), 298-302.
Liang H, Zhao Y, Song Z. [Pulsatile Microdialysis Method With Glucose Sensor System]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 1998;15(3):298-302. PubMed PMID: 12553258.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - [Pulsatile microdialysis method with glucose sensor system]. AU - Liang,H, AU - Zhao,Y, AU - Song,Z, PY - 2003/1/30/pubmed PY - 2004/1/30/medline PY - 2003/1/30/entrez SP - 298 EP - 302 JF - Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi JO - Sheng Wu Yi Xue Gong Cheng Xue Za Zhi VL - 15 IS - 3 N2 - To develop a miniature subcutaneous glucose sensor system, to simplify calibration procedure before or after glucose monitor, and to improve its temperature characteristics, a pulsatile micropump and the microdialysis technique were used. The experiments of glucose recovery in 5.5 mM and 10 mM G.S. and the temperature experiment from 20 degrees C to 40 degrees C were conducted. The results showed that glucose recovery was (97 +/- 2)%, the current values of glucose sensor varied with temperature, but the temperature parameter was only 3.4%. These indicate that the glucose sensor system is miniature and the calibration procedure is simple. Because of its modified temperature characterisic, it is useful to monitor the blood glucose of feverish diabetics. SN - 1001-5515 UR - https://www.unboundmedicine.com/medline/citation/12553258/[Pulsatile_microdialysis_method_with_glucose_sensor_system]_ L2 - https://medlineplus.gov/bloodsugar.html DB - PRIME DP - Unbound Medicine ER -