Effect of different bonding agents on shear bond strengths of composite-bonded porcelain to enamel.
J Prosthet Dent. 2003 Apr; 89(4):394-9.JP

Abstract

STATEMENT OF PROBLEM

The use of bonding agents in the luting procedure for porcelain laminate restorations to enamel is not clear.

PURPOSE

This study evaluated the shear bond strength differences between an enamel-luting composite and a heat-pressed ceramic with 6 different bonding systems.

MATERIAL AND METHODS

Seventy standardized heat-pressed IPS Empress ceramic discs (4-mm diameter, 3-mm height) were prepared. A vertical planar enamel-bonding surface was prepared on the buccal or lingual enamel of 70 freshly extracted sound human molars and premolars. The teeth were oriented to maintain a parallel relationship between the bonding plane and the shear loading axis of a universal testing machine. Tooth specimens were divided into 7 groups (n=10) comprising equal numbers of molars and premolars. The enamel surfaces of specimens in groups 1 through 6 were prepared with 1 of 6 bonding agents (Scotchbond Multi Purpose Plus, Heliobond, PQ1, SE Bond, Prime&Bond NT, and Prompt L-Pop). Finally, the specimens were luted to the ceramic discs with the composite cement (Opal Luting Composite). Ceramic discs in the seventh group (Control) were luted to the etched enamel with the composite cement without using bonding material. Enamel-ceramic specimens were kept in distilled water at room temperature for 30 days after cementation. All specimens were shear loaded axially in a universal testing machine with a crosshead speed of 0.05 mm/min until fracture. Shear bond strength was measured and recorded for each group in MPa. To determine the statistical significance of the differences between the mean shear bond strength values, a 1-way analysis of variance was used (alpha=.05). Post-hoc multiple comparisons were made with Duncan's multiple range analysis. Fractured surfaces of each specimen were also inspected with a stereomicroscope to evaluate failure modes.

RESULTS

A 1-way analysis of variance revealed significant differences between the test groups (P=.00). Bond strength values (MPa) from the highest to the lowest were as follows: Prompt L-Pop, 25.46 +/- 5.6; Prime&Bond NT, 18.99 +/- 4.93; Heliobond, 17.28 +/- 4.0; SE Bond, 16.21 +/- 2.6; PQ1, 15.60 +/- 2.8; Scotchbond MPP, 14.82 +/- 2.4; and Control, 10.55 +/- 1.6. Duncan's multiple range post hoc analysis exhibited significant differences between the control group and the adhesive bonding agent groups (P<.05). There were also significant differences between the bonding agent groups (P<.05). Prompt L-Pop showed the highest bond strength values.

CONCLUSION

Within the limitations of this study, bonding agents appear to have a strengthening effect on the shear bond strengths of the enamel/composite/porcelain interface of the materials tested. Bonding agents used in this study showed similar bond strength values except for Prompt L-Pop, which demonstrated the highest bond strength values.

Authors+Show Affiliations

Department of Prosthodontics, Faculty of Dentistry, Ege University, Izmir, Turkey. cenkcura@hotmail.comNo affiliation info availableNo affiliation info available

Pub Type(s)

Clinical Trial
Journal Article

Language

eng

PubMed ID

12690353

Citation

Cura, Cenk, et al. "Effect of Different Bonding Agents On Shear Bond Strengths of Composite-bonded Porcelain to Enamel." The Journal of Prosthetic Dentistry, vol. 89, no. 4, 2003, pp. 394-9.
Cura C, Saraçoglu A, Cötert HS. Effect of different bonding agents on shear bond strengths of composite-bonded porcelain to enamel. J Prosthet Dent. 2003;89(4):394-9.
Cura, C., Saraçoglu, A., & Cötert, H. S. (2003). Effect of different bonding agents on shear bond strengths of composite-bonded porcelain to enamel. The Journal of Prosthetic Dentistry, 89(4), 394-9.
Cura C, Saraçoglu A, Cötert HS. Effect of Different Bonding Agents On Shear Bond Strengths of Composite-bonded Porcelain to Enamel. J Prosthet Dent. 2003;89(4):394-9. PubMed PMID: 12690353.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Effect of different bonding agents on shear bond strengths of composite-bonded porcelain to enamel. AU - Cura,Cenk, AU - Saraçoglu,Ahmet, AU - Cötert,H Serdar, PY - 2003/4/12/pubmed PY - 2003/7/11/medline PY - 2003/4/12/entrez SP - 394 EP - 9 JF - The Journal of prosthetic dentistry JO - J Prosthet Dent VL - 89 IS - 4 N2 - STATEMENT OF PROBLEM: The use of bonding agents in the luting procedure for porcelain laminate restorations to enamel is not clear. PURPOSE: This study evaluated the shear bond strength differences between an enamel-luting composite and a heat-pressed ceramic with 6 different bonding systems. MATERIAL AND METHODS: Seventy standardized heat-pressed IPS Empress ceramic discs (4-mm diameter, 3-mm height) were prepared. A vertical planar enamel-bonding surface was prepared on the buccal or lingual enamel of 70 freshly extracted sound human molars and premolars. The teeth were oriented to maintain a parallel relationship between the bonding plane and the shear loading axis of a universal testing machine. Tooth specimens were divided into 7 groups (n=10) comprising equal numbers of molars and premolars. The enamel surfaces of specimens in groups 1 through 6 were prepared with 1 of 6 bonding agents (Scotchbond Multi Purpose Plus, Heliobond, PQ1, SE Bond, Prime&Bond NT, and Prompt L-Pop). Finally, the specimens were luted to the ceramic discs with the composite cement (Opal Luting Composite). Ceramic discs in the seventh group (Control) were luted to the etched enamel with the composite cement without using bonding material. Enamel-ceramic specimens were kept in distilled water at room temperature for 30 days after cementation. All specimens were shear loaded axially in a universal testing machine with a crosshead speed of 0.05 mm/min until fracture. Shear bond strength was measured and recorded for each group in MPa. To determine the statistical significance of the differences between the mean shear bond strength values, a 1-way analysis of variance was used (alpha=.05). Post-hoc multiple comparisons were made with Duncan's multiple range analysis. Fractured surfaces of each specimen were also inspected with a stereomicroscope to evaluate failure modes. RESULTS: A 1-way analysis of variance revealed significant differences between the test groups (P=.00). Bond strength values (MPa) from the highest to the lowest were as follows: Prompt L-Pop, 25.46 +/- 5.6; Prime&Bond NT, 18.99 +/- 4.93; Heliobond, 17.28 +/- 4.0; SE Bond, 16.21 +/- 2.6; PQ1, 15.60 +/- 2.8; Scotchbond MPP, 14.82 +/- 2.4; and Control, 10.55 +/- 1.6. Duncan's multiple range post hoc analysis exhibited significant differences between the control group and the adhesive bonding agent groups (P<.05). There were also significant differences between the bonding agent groups (P<.05). Prompt L-Pop showed the highest bond strength values. CONCLUSION: Within the limitations of this study, bonding agents appear to have a strengthening effect on the shear bond strengths of the enamel/composite/porcelain interface of the materials tested. Bonding agents used in this study showed similar bond strength values except for Prompt L-Pop, which demonstrated the highest bond strength values. SN - 0022-3913 UR - https://www.unboundmedicine.com/medline/citation/12690353/Effect_of_different_bonding_agents_on_shear_bond_strengths_of_composite_bonded_porcelain_to_enamel_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S002239130252758X DB - PRIME DP - Unbound Medicine ER -