Optimization of the chiral resolution of baclofen by capillary electrophoresis using beta-cyclodextrin as the chiral selector.Electrophoresis. 2003 Jun; 24(12-13):2064-2069.E
Abstract
The chiral resolution of baclofen was achieved by capillary electrophoresis using a fused-silica capillary (60 cm x 75 microm ID). The background electrolyte (BGE) was phosphate buffer (pH 7.0, 50 mM)-acetonitrile (95:5 v/v) containing 10 mM beta-cyclodextrin. The applied voltage was 15 kV. The values of alpha and R(s) were 1.06 and 1.00, respectively. The electrophoretic conditions were optimized varying the pH and the ionic strength of the BGE, concentrations of beta-cyclodextrin and acetonitrile and the applied voltage.
Links
MeSH
Pub Type(s)
Journal Article
Language
eng
PubMed ID
12858376
Citation
Ali, Imran, and Hassan Y. Aboul-Enein. "Optimization of the Chiral Resolution of Baclofen By Capillary Electrophoresis Using Beta-cyclodextrin as the Chiral Selector." Electrophoresis, vol. 24, no. 12-13, 2003, pp. 2064-2069.
Ali I, Aboul-Enein HY. Optimization of the chiral resolution of baclofen by capillary electrophoresis using beta-cyclodextrin as the chiral selector. Electrophoresis. 2003;24(12-13):2064-2069.
Ali, I., & Aboul-Enein, H. Y. (2003). Optimization of the chiral resolution of baclofen by capillary electrophoresis using beta-cyclodextrin as the chiral selector. Electrophoresis, 24(12-13), 2064-2069. https://doi.org/10.1002/elps.200305439
Ali I, Aboul-Enein HY. Optimization of the Chiral Resolution of Baclofen By Capillary Electrophoresis Using Beta-cyclodextrin as the Chiral Selector. Electrophoresis. 2003;24(12-13):2064-2069. PubMed PMID: 12858376.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - Optimization of the chiral resolution of baclofen by capillary electrophoresis using beta-cyclodextrin as the chiral selector.
AU - Ali,Imran,
AU - Aboul-Enein,Hassan Y,
PY - 2003/7/15/pubmed
PY - 2004/4/8/medline
PY - 2003/7/15/entrez
SP - 2064
EP - 2069
JF - Electrophoresis
JO - Electrophoresis
VL - 24
IS - 12-13
N2 - The chiral resolution of baclofen was achieved by capillary electrophoresis using a fused-silica capillary (60 cm x 75 microm ID). The background electrolyte (BGE) was phosphate buffer (pH 7.0, 50 mM)-acetonitrile (95:5 v/v) containing 10 mM beta-cyclodextrin. The applied voltage was 15 kV. The values of alpha and R(s) were 1.06 and 1.00, respectively. The electrophoretic conditions were optimized varying the pH and the ionic strength of the BGE, concentrations of beta-cyclodextrin and acetonitrile and the applied voltage.
SN - 0173-0835
UR - https://www.unboundmedicine.com/medline/citation/12858376/Optimization_of_the_chiral_resolution_of_baclofen_by_capillary_electrophoresis_using_beta_cyclodextrin_as_the_chiral_selector_
DB - PRIME
DP - Unbound Medicine
ER -