[Effects of biomicrosphere on the cochlear blood flow, blood pressure and heart rate in guinea pigs].Zhonghua Er Bi Yan Hou Ke Za Zhi. 1992; 27(4):216-8, 255.ZE
Abstract
Cochlear blood flow (CBF) in guinea pigs was measured by Laser Doppler flowmeter and biomicrosphere method. The effects of dosages of biomicrospheres and time factor on the CBF, blood pressure and heart rate were observed. The findings suggest that 9 x 10(6). 10.5 x 10(6) biomicrospheres may be most suitable for measuring CBF with biomicrosphere method, and some physiological parameters of the guinea pig must be taken down within 2-10 minutes after microsphere injection.
MeSH
Pub Type(s)
English Abstract
Journal Article
Language
chi
PubMed ID
1298309
Citation
Lo, R Z.. "[Effects of Biomicrosphere On the Cochlear Blood Flow, Blood Pressure and Heart Rate in Guinea Pigs]." Zhonghua Er Bi Yan Hou Ke Za Zhi, vol. 27, no. 4, 1992, pp. 216-8, 255.
Lo RZ. [Effects of biomicrosphere on the cochlear blood flow, blood pressure and heart rate in guinea pigs]. Zhonghua Er Bi Yan Hou Ke Za Zhi. 1992;27(4):216-8, 255.
Lo, R. Z. (1992). [Effects of biomicrosphere on the cochlear blood flow, blood pressure and heart rate in guinea pigs]. Zhonghua Er Bi Yan Hou Ke Za Zhi, 27(4), 216-8, 255.
Lo RZ. [Effects of Biomicrosphere On the Cochlear Blood Flow, Blood Pressure and Heart Rate in Guinea Pigs]. Zhonghua Er Bi Yan Hou Ke Za Zhi. 1992;27(4):216-8, 255. PubMed PMID: 1298309.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - [Effects of biomicrosphere on the cochlear blood flow, blood pressure and heart rate in guinea pigs].
A1 - Lo,R Z,
PY - 1992/1/1/pubmed
PY - 1992/1/1/medline
PY - 1992/1/1/entrez
SP - 216-8, 255
JF - Zhonghua er bi yan hou ke za zhi
JO - Zhonghua Er Bi Yan Hou Ke Za Zhi
VL - 27
IS - 4
N2 - Cochlear blood flow (CBF) in guinea pigs was measured by Laser Doppler flowmeter and biomicrosphere method. The effects of dosages of biomicrospheres and time factor on the CBF, blood pressure and heart rate were observed. The findings suggest that 9 x 10(6). 10.5 x 10(6) biomicrospheres may be most suitable for measuring CBF with biomicrosphere method, and some physiological parameters of the guinea pig must be taken down within 2-10 minutes after microsphere injection.
SN - 0412-3948
UR - https://www.unboundmedicine.com/medline/citation/1298309/[Effects_of_biomicrosphere_on_the_cochlear_blood_flow_blood_pressure_and_heart_rate_in_guinea_pigs]_
DB - PRIME
DP - Unbound Medicine
ER -