Tags

Type your tag names separated by a space and hit enter

[Effects of biomicrosphere on the cochlear blood flow, blood pressure and heart rate in guinea pigs].
Zhonghua Er Bi Yan Hou Ke Za Zhi. 1992; 27(4):216-8, 255.ZE

Abstract

Cochlear blood flow (CBF) in guinea pigs was measured by Laser Doppler flowmeter and biomicrosphere method. The effects of dosages of biomicrospheres and time factor on the CBF, blood pressure and heart rate were observed. The findings suggest that 9 x 10(6). 10.5 x 10(6) biomicrospheres may be most suitable for measuring CBF with biomicrosphere method, and some physiological parameters of the guinea pig must be taken down within 2-10 minutes after microsphere injection.

Authors+Show Affiliations

Union Hospital, Tong Ji Medical University, Wuhan.

Pub Type(s)

English Abstract
Journal Article

Language

chi

PubMed ID

1298309

Citation

Lo, R Z.. "[Effects of Biomicrosphere On the Cochlear Blood Flow, Blood Pressure and Heart Rate in Guinea Pigs]." Zhonghua Er Bi Yan Hou Ke Za Zhi, vol. 27, no. 4, 1992, pp. 216-8, 255.
Lo RZ. [Effects of biomicrosphere on the cochlear blood flow, blood pressure and heart rate in guinea pigs]. Zhonghua Er Bi Yan Hou Ke Za Zhi. 1992;27(4):216-8, 255.
Lo, R. Z. (1992). [Effects of biomicrosphere on the cochlear blood flow, blood pressure and heart rate in guinea pigs]. Zhonghua Er Bi Yan Hou Ke Za Zhi, 27(4), 216-8, 255.
Lo RZ. [Effects of Biomicrosphere On the Cochlear Blood Flow, Blood Pressure and Heart Rate in Guinea Pigs]. Zhonghua Er Bi Yan Hou Ke Za Zhi. 1992;27(4):216-8, 255. PubMed PMID: 1298309.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - [Effects of biomicrosphere on the cochlear blood flow, blood pressure and heart rate in guinea pigs]. A1 - Lo,R Z, PY - 1992/1/1/pubmed PY - 1992/1/1/medline PY - 1992/1/1/entrez SP - 216-8, 255 JF - Zhonghua er bi yan hou ke za zhi JO - Zhonghua Er Bi Yan Hou Ke Za Zhi VL - 27 IS - 4 N2 - Cochlear blood flow (CBF) in guinea pigs was measured by Laser Doppler flowmeter and biomicrosphere method. The effects of dosages of biomicrospheres and time factor on the CBF, blood pressure and heart rate were observed. The findings suggest that 9 x 10(6). 10.5 x 10(6) biomicrospheres may be most suitable for measuring CBF with biomicrosphere method, and some physiological parameters of the guinea pig must be taken down within 2-10 minutes after microsphere injection. SN - 0412-3948 UR - https://www.unboundmedicine.com/medline/citation/1298309/[Effects_of_biomicrosphere_on_the_cochlear_blood_flow_blood_pressure_and_heart_rate_in_guinea_pigs]_ DB - PRIME DP - Unbound Medicine ER -