The mechanical behaviour of cantilever fixed partial dentures in shortened dental arch therapy: a 2-D finite element analysis.Eur J Prosthodont Restor Dent. 2004 Mar; 12(1):21-7.EJ
Abstract
In the present study two-dimensional finite element models of two- and three-unit cantilever fixed partial dentures were created to simulate the replacement of a maxillary second premolar in a shortened dental arch. The purpose of the study was to investigate the mechanical behaviour of the two designs of fixed partial denture using the finite element method. The results indicate that the mechanical behaviour of the three-unit fixed partial denture was more favourable than that of the two-unit fixed partial denture under similar conditions of occlusal loading. Prosthesis displacement and maximum principal stresses increased substantially when loading was limited to the pontic, in particular, in the model of two-unit fixed partial denture.
MeSH
Pub Type(s)
Journal Article
Language
eng
PubMed ID
15058178
Citation
Romeed, Shihab A., et al. "The Mechanical Behaviour of Cantilever Fixed Partial Dentures in Shortened Dental Arch Therapy: a 2-D Finite Element Analysis." The European Journal of Prosthodontics and Restorative Dentistry, vol. 12, no. 1, 2004, pp. 21-7.
Romeed SA, Fok SL, Wilson NH. The mechanical behaviour of cantilever fixed partial dentures in shortened dental arch therapy: a 2-D finite element analysis. Eur J Prosthodont Restor Dent. 2004;12(1):21-7.
Romeed, S. A., Fok, S. L., & Wilson, N. H. (2004). The mechanical behaviour of cantilever fixed partial dentures in shortened dental arch therapy: a 2-D finite element analysis. The European Journal of Prosthodontics and Restorative Dentistry, 12(1), 21-7.
Romeed SA, Fok SL, Wilson NH. The Mechanical Behaviour of Cantilever Fixed Partial Dentures in Shortened Dental Arch Therapy: a 2-D Finite Element Analysis. Eur J Prosthodont Restor Dent. 2004;12(1):21-7. PubMed PMID: 15058178.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - The mechanical behaviour of cantilever fixed partial dentures in shortened dental arch therapy: a 2-D finite element analysis.
AU - Romeed,Shihab A,
AU - Fok,Siu L,
AU - Wilson,Nairn H,
PY - 2004/4/3/pubmed
PY - 2004/4/28/medline
PY - 2004/4/3/entrez
SP - 21
EP - 7
JF - The European journal of prosthodontics and restorative dentistry
JO - Eur J Prosthodont Restor Dent
VL - 12
IS - 1
N2 - In the present study two-dimensional finite element models of two- and three-unit cantilever fixed partial dentures were created to simulate the replacement of a maxillary second premolar in a shortened dental arch. The purpose of the study was to investigate the mechanical behaviour of the two designs of fixed partial denture using the finite element method. The results indicate that the mechanical behaviour of the three-unit fixed partial denture was more favourable than that of the two-unit fixed partial denture under similar conditions of occlusal loading. Prosthesis displacement and maximum principal stresses increased substantially when loading was limited to the pontic, in particular, in the model of two-unit fixed partial denture.
SN - 0965-7452
UR - https://www.unboundmedicine.com/medline/citation/15058178/The_mechanical_behaviour_of_cantilever_fixed_partial_dentures_in_shortened_dental_arch_therapy:_a_2_D_finite_element_analysis_
DB - PRIME
DP - Unbound Medicine
ER -