This paper proposes a very simple procedure for preparing a biocompatible sensor based on a protein (bovine serum albumin, BSA), enzyme and vinylferrocene (VF) composite membrane modified electrode. The membrane was prepared simply by first casting vinylferrocene and then coating it with BSA and glucose oxidase immobilised with glutaraldehyde. The sensor response was independent of dissolved oxygen concentration from 3 to 10 ppm and showed good stability for serum sample measurement, unlike the commonly used BSA/enzyme modified electrode. The sensor response was almost unchanged over the measurement time (>10 h) whereas the responses of a BSA and glucose oxidase modified platinum electrode and an osmium-polyvinylpyridine wired horseradish peroxidase modified electrode (Ohara et al., 1993) fell to 68% of their initial value in a serum sample containing 10mM glucose.

Authors+Show Affiliations

NTT Advanced Technology, 3-1 Morinosato-Wakamiya, Atsugi, Kanagawa 243-0198, Japan. kurita@atsugi.ntt-at.co.jpNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Evaluation Study
Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

15494234

Citation

Kurita, Ryoji, et al. "Biocompatible Glucose Sensor Prepared By Modifying Protein and Vinylferrocene Monomer Composite Membrane." Biosensors & Bioelectronics, vol. 20, no. 3, 2004, pp. 518-23.
Kurita R, Tabei H, Iwasaki Y, et al. Biocompatible glucose sensor prepared by modifying protein and vinylferrocene monomer composite membrane. Biosens Bioelectron. 2004;20(3):518-23.
Kurita, R., Tabei, H., Iwasaki, Y., Hayashi, K., Sunagawa, K., & Niwa, O. (2004). Biocompatible glucose sensor prepared by modifying protein and vinylferrocene monomer composite membrane. Biosensors & Bioelectronics, 20(3), 518-23.
Kurita R, et al. Biocompatible Glucose Sensor Prepared By Modifying Protein and Vinylferrocene Monomer Composite Membrane. Biosens Bioelectron. 2004 Oct 15;20(3):518-23. PubMed PMID: 15494234.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Biocompatible glucose sensor prepared by modifying protein and vinylferrocene monomer composite membrane. AU - Kurita,Ryoji, AU - Tabei,Hisao, AU - Iwasaki,Yuzuru, AU - Hayashi,Katsuyoshi, AU - Sunagawa,Kenji, AU - Niwa,Osamu, PY - 2003/12/18/received PY - 2004/02/25/revised PY - 2004/02/25/accepted PY - 2004/10/21/pubmed PY - 2005/5/25/medline PY - 2004/10/21/entrez SP - 518 EP - 23 JF - Biosensors & bioelectronics JO - Biosens Bioelectron VL - 20 IS - 3 N2 - This paper proposes a very simple procedure for preparing a biocompatible sensor based on a protein (bovine serum albumin, BSA), enzyme and vinylferrocene (VF) composite membrane modified electrode. The membrane was prepared simply by first casting vinylferrocene and then coating it with BSA and glucose oxidase immobilised with glutaraldehyde. The sensor response was independent of dissolved oxygen concentration from 3 to 10 ppm and showed good stability for serum sample measurement, unlike the commonly used BSA/enzyme modified electrode. The sensor response was almost unchanged over the measurement time (>10 h) whereas the responses of a BSA and glucose oxidase modified platinum electrode and an osmium-polyvinylpyridine wired horseradish peroxidase modified electrode (Ohara et al., 1993) fell to 68% of their initial value in a serum sample containing 10mM glucose. SN - 0956-5663 UR - https://www.unboundmedicine.com/medline/citation/15494234/Biocompatible_glucose_sensor_prepared_by_modifying_protein_and_vinylferrocene_monomer_composite_membrane_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S095656630400096X DB - PRIME DP - Unbound Medicine ER -