Tags

Type your tag names separated by a space and hit enter

A method for routine quantitation of urinary 8-hydroxy-2'-deoxyguanosine based on solid-phase extraction and micro-high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.
Rapid Commun Mass Spectrom. 2005; 19(2):147-52.RC

Abstract

8-Hydroxy-2'-deoxyguanosine (8OHdG), one of the major oxidative DNA lesions induced by radical agents, is commonly used as a biomarker for oxidative stress, nowadays preferably in urine. In the absence of a commercially available internal standard a micro-high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (micro-HPLC/ESI-MS/MS) method, suitable for routine analysis of 8OHdG in human urine using external calibration, was developed. Evaluation of the matrix effect showed that the method allows highly sensitive and accurate quantitation despite the absence of an internal standard. HPLC analysis was performed using gradient elution at a flow rate of 10 microL min(-1) using a capillary reversed-phase column and an injection volume of 0.5 microL, with detection of 8OHdG in positive multiple reaction monitoring (MRM) mode. The absolute limit of detection was 0.35 fmol using m/z 168 as a quantifier (fragment) ion. A linear (R2> 0.999) calibration curve in urine was obtained over a range 0.2-10 ng mL(-1). This method is about 20 times more sensitive than previously described procedures, and is characterized by high accuracy (mean 90%) and good reproducibility (RSD <10%). The optimized method was applied to determination of 8OHdG in 18 urinary samples derived from three healthy volunteers. 8OHdG urinary excretion ranged from 3.0-7.9 microg/day, and a large intra-individual variation was found. This method, which effectively circumvents the need for isotopically labeled 8OHdG (internal standard), is suitable for routine monitoring of exposure to DNA-damaging factors in a large number of subjects.

Authors+Show Affiliations

Occupational Medicine Unit, University of Bologna, S. Orsola-Malpighi Hospital, via Palagi 9, 40138 Bologna, Italy.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

15593068

Citation

Sabatini, Laura, et al. "A Method for Routine Quantitation of Urinary 8-hydroxy-2'-deoxyguanosine Based On Solid-phase Extraction and Micro-high-performance Liquid Chromatography/electrospray Ionization Tandem Mass Spectrometry." Rapid Communications in Mass Spectrometry : RCM, vol. 19, no. 2, 2005, pp. 147-52.
Sabatini L, Barbieri A, Tosi M, et al. A method for routine quantitation of urinary 8-hydroxy-2'-deoxyguanosine based on solid-phase extraction and micro-high-performance liquid chromatography/electrospray ionization tandem mass spectrometry. Rapid Commun Mass Spectrom. 2005;19(2):147-52.
Sabatini, L., Barbieri, A., Tosi, M., Roda, A., & Violante, F. S. (2005). A method for routine quantitation of urinary 8-hydroxy-2'-deoxyguanosine based on solid-phase extraction and micro-high-performance liquid chromatography/electrospray ionization tandem mass spectrometry. Rapid Communications in Mass Spectrometry : RCM, 19(2), 147-52.
Sabatini L, et al. A Method for Routine Quantitation of Urinary 8-hydroxy-2'-deoxyguanosine Based On Solid-phase Extraction and Micro-high-performance Liquid Chromatography/electrospray Ionization Tandem Mass Spectrometry. Rapid Commun Mass Spectrom. 2005;19(2):147-52. PubMed PMID: 15593068.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - A method for routine quantitation of urinary 8-hydroxy-2'-deoxyguanosine based on solid-phase extraction and micro-high-performance liquid chromatography/electrospray ionization tandem mass spectrometry. AU - Sabatini,Laura, AU - Barbieri,Anna, AU - Tosi,Marco, AU - Roda,Aldo, AU - Violante,Francesco Saverio, PY - 2004/12/14/pubmed PY - 2005/3/9/medline PY - 2004/12/14/entrez SP - 147 EP - 52 JF - Rapid communications in mass spectrometry : RCM JO - Rapid Commun Mass Spectrom VL - 19 IS - 2 N2 - 8-Hydroxy-2'-deoxyguanosine (8OHdG), one of the major oxidative DNA lesions induced by radical agents, is commonly used as a biomarker for oxidative stress, nowadays preferably in urine. In the absence of a commercially available internal standard a micro-high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (micro-HPLC/ESI-MS/MS) method, suitable for routine analysis of 8OHdG in human urine using external calibration, was developed. Evaluation of the matrix effect showed that the method allows highly sensitive and accurate quantitation despite the absence of an internal standard. HPLC analysis was performed using gradient elution at a flow rate of 10 microL min(-1) using a capillary reversed-phase column and an injection volume of 0.5 microL, with detection of 8OHdG in positive multiple reaction monitoring (MRM) mode. The absolute limit of detection was 0.35 fmol using m/z 168 as a quantifier (fragment) ion. A linear (R2> 0.999) calibration curve in urine was obtained over a range 0.2-10 ng mL(-1). This method is about 20 times more sensitive than previously described procedures, and is characterized by high accuracy (mean 90%) and good reproducibility (RSD <10%). The optimized method was applied to determination of 8OHdG in 18 urinary samples derived from three healthy volunteers. 8OHdG urinary excretion ranged from 3.0-7.9 microg/day, and a large intra-individual variation was found. This method, which effectively circumvents the need for isotopically labeled 8OHdG (internal standard), is suitable for routine monitoring of exposure to DNA-damaging factors in a large number of subjects. SN - 0951-4198 UR - https://www.unboundmedicine.com/medline/citation/15593068/A_method_for_routine_quantitation_of_urinary_8_hydroxy_2'_deoxyguanosine_based_on_solid_phase_extraction_and_micro_high_performance_liquid_chromatography/electrospray_ionization_tandem_mass_spectrometry_ DB - PRIME DP - Unbound Medicine ER -