Tags

Type your tag names separated by a space and hit enter

Simultaneous determination of mycophenolic acid and its phenolic glucuronide in human plasma using an isocratic high-performance liquid chromatography procedure.
J Chromatogr B Analyt Technol Biomed Life Sci. 2005 Mar 25; 817(2):327-30.JC

Abstract

Simultaneous determination of mycophenolic acid (MPA) and mycophenolic acid glucuronide (MPAG) in plasma was accomplished by isocratic HPLC with UV detection. After protein precipitation and phase separation with saturated sodium dihydrogenphosphate, chromatographic separation was achieved on a monolithic column "Chromolith Performance RP-18e", with acetonitrile/0.01 M phosphate buffer, pH 3, (25:75, v/v), as the mobile phase; flow rate 3.3 ml/min and measurement at 214 nm. Linearity was verified up to 40 mg/l for MPA and up to 400 mg/l for MPAG. Detection limits based on the analysis of 50 microl plasma were 0.05 and 0.5 mg/l for MPA and MPAG, respectively. Accuracy was 99.6-104% for MPA and 95.6-105% for MPAG and total imprecision (CV) was <7% for both compounds. Analytical recovery was >95% for MPA and MPAG. The method is simple, rapid, accurate and suitable for routine determination of MPA and MPAG in plasma.

Authors+Show Affiliations

Department of Clinical Laboratory, Alexander University Hospital, Medical University of Sofia, Georgi Sofiiski Street 1, 1431 Sofia, Bulgaria. dindjova@yahoo.comNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

15687002

Citation

Indjova, Dessislava, et al. "Simultaneous Determination of Mycophenolic Acid and Its Phenolic Glucuronide in Human Plasma Using an Isocratic High-performance Liquid Chromatography Procedure." Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences, vol. 817, no. 2, 2005, pp. 327-30.
Indjova D, Kassabova L, Svinarov D. Simultaneous determination of mycophenolic acid and its phenolic glucuronide in human plasma using an isocratic high-performance liquid chromatography procedure. J Chromatogr B Analyt Technol Biomed Life Sci. 2005;817(2):327-30.
Indjova, D., Kassabova, L., & Svinarov, D. (2005). Simultaneous determination of mycophenolic acid and its phenolic glucuronide in human plasma using an isocratic high-performance liquid chromatography procedure. Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences, 817(2), 327-30.
Indjova D, Kassabova L, Svinarov D. Simultaneous Determination of Mycophenolic Acid and Its Phenolic Glucuronide in Human Plasma Using an Isocratic High-performance Liquid Chromatography Procedure. J Chromatogr B Analyt Technol Biomed Life Sci. 2005 Mar 25;817(2):327-30. PubMed PMID: 15687002.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Simultaneous determination of mycophenolic acid and its phenolic glucuronide in human plasma using an isocratic high-performance liquid chromatography procedure. AU - Indjova,Dessislava, AU - Kassabova,Lilia, AU - Svinarov,Dobrin, PY - 2004/08/23/received PY - 2004/11/11/accepted PY - 2005/2/3/pubmed PY - 2005/9/2/medline PY - 2005/2/3/entrez SP - 327 EP - 30 JF - Journal of chromatography. B, Analytical technologies in the biomedical and life sciences JO - J Chromatogr B Analyt Technol Biomed Life Sci VL - 817 IS - 2 N2 - Simultaneous determination of mycophenolic acid (MPA) and mycophenolic acid glucuronide (MPAG) in plasma was accomplished by isocratic HPLC with UV detection. After protein precipitation and phase separation with saturated sodium dihydrogenphosphate, chromatographic separation was achieved on a monolithic column "Chromolith Performance RP-18e", with acetonitrile/0.01 M phosphate buffer, pH 3, (25:75, v/v), as the mobile phase; flow rate 3.3 ml/min and measurement at 214 nm. Linearity was verified up to 40 mg/l for MPA and up to 400 mg/l for MPAG. Detection limits based on the analysis of 50 microl plasma were 0.05 and 0.5 mg/l for MPA and MPAG, respectively. Accuracy was 99.6-104% for MPA and 95.6-105% for MPAG and total imprecision (CV) was <7% for both compounds. Analytical recovery was >95% for MPA and MPAG. The method is simple, rapid, accurate and suitable for routine determination of MPA and MPAG in plasma. SN - 1570-0232 UR - https://www.unboundmedicine.com/medline/citation/15687002/Simultaneous_determination_of_mycophenolic_acid_and_its_phenolic_glucuronide_in_human_plasma_using_an_isocratic_high_performance_liquid_chromatography_procedure_ DB - PRIME DP - Unbound Medicine ER -