Development of a liquid chromatography/tandem mass spectrometry assay for the quantification of PM00104, a novel antineoplastic agent, in mouse, rat, dog, and human plasma.
Rapid Commun Mass Spectrom. 2005; 19(5):689-95.RC

Abstract

A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay was developed and validated to quantify a novel antineoplastic agent, PM00104, in mouse, rat, dog, and human plasma. The method was validated to demonstrate the specificity, limit of quantification (LOQ), accuracy, and precision of measurements. The calibration range for PM00104 was established using PM00104 standards from 0.01-5.0 ng/mL in blank plasma. The selected reaction monitoring (SRM), based on the m/z 692.2 --> 218.2 transition, was specific for PM00104, and that based on the m/z 697.2 --> 218.2 transition was specific for PM00104 ((13)C(2),(2)H(3)) (the internal standard, IS); no endogenous materials interfered with the analysis of PM00104 and IS from blank plasma. The assay was linear over the concentration range 0.01-5.0 ng/mL. The correlation coefficients for the calibration curves ranged from 0.9981-0.9999. The mean intra-day and inter-day accuracies for all calibration standards (n = 8) ranged from 97-105% (< or =5% bias) in human plasma, and the mean inter-day precision for all calibration standards was less than 8.5%. The mean intra- and inter-day assay accuracy for all quality control (QC) replicates in human plasma (n = 9), determined at each QC level throughout the validated runs, ranged from 96-112% (< or =12% bias) and from 102-105% (< or =5% bias), respectively. The mean intra- and inter-day assay precision was less than 15.0 and 11.8% for all QC levels, respectively. For the QC samples prepared in animal species plasma, the %CV values of the assays ranged from 1.8-8.8% in mouse plasma, from 3.7-13.8% in rat plasma, and from 3.0-7.2% in dog plasma. The assay accuracies ranged from 92-102% (< or =8% bias) for all QC levels prepared in mouse plasma; ranged from 93-106% (< or =7% bias) in rat plasma; and ranged from 95-114% (< or =14% bias) in dog plasma. The assay has been used to support preclinical pharmacokinetic and toxicokinetic studies and is currently used to measure PM00104 plasma concentrations to support clinical trials.

Authors+Show Affiliations

PharmaMar USA, Inc., 320 Putnam Avenue, Cambridge, MA 02139-4616, USA. jyin@pharmamarusa.comNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Comparative Study
Evaluation Study
Journal Article

Language

eng

PubMed ID

15702485

Citation

Yin, Jianming, et al. "Development of a Liquid Chromatography/tandem Mass Spectrometry Assay for the Quantification of PM00104, a Novel Antineoplastic Agent, in Mouse, Rat, Dog, and Human Plasma." Rapid Communications in Mass Spectrometry : RCM, vol. 19, no. 5, 2005, pp. 689-95.
Yin J, Aviles P, Lee W, et al. Development of a liquid chromatography/tandem mass spectrometry assay for the quantification of PM00104, a novel antineoplastic agent, in mouse, rat, dog, and human plasma. Rapid Commun Mass Spectrom. 2005;19(5):689-95.
Yin, J., Aviles, P., Lee, W., Ly, C., Guillen, M. J., Munt, S., Cuevas, C., & Faircloth, G. (2005). Development of a liquid chromatography/tandem mass spectrometry assay for the quantification of PM00104, a novel antineoplastic agent, in mouse, rat, dog, and human plasma. Rapid Communications in Mass Spectrometry : RCM, 19(5), 689-95.
Yin J, et al. Development of a Liquid Chromatography/tandem Mass Spectrometry Assay for the Quantification of PM00104, a Novel Antineoplastic Agent, in Mouse, Rat, Dog, and Human Plasma. Rapid Commun Mass Spectrom. 2005;19(5):689-95. PubMed PMID: 15702485.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Development of a liquid chromatography/tandem mass spectrometry assay for the quantification of PM00104, a novel antineoplastic agent, in mouse, rat, dog, and human plasma. AU - Yin,Jianming, AU - Aviles,Pablo, AU - Lee,William, AU - Ly,Carl, AU - Guillen,Maria Jose, AU - Munt,Simon, AU - Cuevas,Carmen, AU - Faircloth,Glynn, PY - 2005/2/11/pubmed PY - 2005/5/17/medline PY - 2005/2/11/entrez SP - 689 EP - 95 JF - Rapid communications in mass spectrometry : RCM JO - Rapid Commun Mass Spectrom VL - 19 IS - 5 N2 - A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay was developed and validated to quantify a novel antineoplastic agent, PM00104, in mouse, rat, dog, and human plasma. The method was validated to demonstrate the specificity, limit of quantification (LOQ), accuracy, and precision of measurements. The calibration range for PM00104 was established using PM00104 standards from 0.01-5.0 ng/mL in blank plasma. The selected reaction monitoring (SRM), based on the m/z 692.2 --> 218.2 transition, was specific for PM00104, and that based on the m/z 697.2 --> 218.2 transition was specific for PM00104 ((13)C(2),(2)H(3)) (the internal standard, IS); no endogenous materials interfered with the analysis of PM00104 and IS from blank plasma. The assay was linear over the concentration range 0.01-5.0 ng/mL. The correlation coefficients for the calibration curves ranged from 0.9981-0.9999. The mean intra-day and inter-day accuracies for all calibration standards (n = 8) ranged from 97-105% (< or =5% bias) in human plasma, and the mean inter-day precision for all calibration standards was less than 8.5%. The mean intra- and inter-day assay accuracy for all quality control (QC) replicates in human plasma (n = 9), determined at each QC level throughout the validated runs, ranged from 96-112% (< or =12% bias) and from 102-105% (< or =5% bias), respectively. The mean intra- and inter-day assay precision was less than 15.0 and 11.8% for all QC levels, respectively. For the QC samples prepared in animal species plasma, the %CV values of the assays ranged from 1.8-8.8% in mouse plasma, from 3.7-13.8% in rat plasma, and from 3.0-7.2% in dog plasma. The assay accuracies ranged from 92-102% (< or =8% bias) for all QC levels prepared in mouse plasma; ranged from 93-106% (< or =7% bias) in rat plasma; and ranged from 95-114% (< or =14% bias) in dog plasma. The assay has been used to support preclinical pharmacokinetic and toxicokinetic studies and is currently used to measure PM00104 plasma concentrations to support clinical trials. SN - 0951-4198 UR - https://www.unboundmedicine.com/medline/citation/15702485/Development_of_a_liquid_chromatography/tandem_mass_spectrometry_assay_for_the_quantification_of_PM00104_a_novel_antineoplastic_agent_in_mouse_rat_dog_and_human_plasma_ DB - PRIME DP - Unbound Medicine ER -