Patellofemoral forces after total knee arthroplasty: effect of extensor moment arm.
Knee. 2005 Apr; 12(2):81-8.KNEE

Abstract

Total knee arthroplasty implant designs with larger extensor moment arms theoretically should generate lower extensor forces for the same externally applied loads. This study measured knee kinematics, quadriceps forces, and patellofemoral forces under conditions of dynamic knee extension under load in two knee designs with differing quadriceps moment arms. Six human cadaver knees were tested both before implantation and after sequential implantation with two posterior cruciate retaining designs. The extensor moment arm of the LMA (long extensor moment arm design, Scorpio, Howmedica Osteonics, Rutherford, NJ) was approximately 1 cm longer than that of the Control design (7000, Howmedica Osteonics). Quadriceps tension was measured during dynamic closed kinetic chain knee extension. Patellar compressive and shear forces were also recorded using a patellar component instrumented with a custom triaxial load transducer. Knee kinematics were monitored using a three-dimensional electromagnetic tracking device. Both designs produced similar patterns of femoral rollback and tibial rotation. Quadriceps tension was lower in the LMA design compared with the Control design. Patellofemoral compressive forces were also significantly reduced in the LMA design when compared with Control (8-18% lower at angles greater than 50 degrees flexion). The design with the longer extensor moment arm required less quadriceps force to extend the knee under load and reduced patellofemoral compressive forces. Reduced quadriceps forces may facilitate postoperative rehabilitation and activities such as stair climbing. Reduction in patellofemoral forces could reduce patellar complications such as anterior knee pain, component wear, and loosening.

Authors+Show Affiliations

Orthopaedic Research Laboratories, Scripps Clinic Center for Orthopaedic Research and Education, 11025 N Torrey Pines Road, Suite 140, La Jolla, CA 92037, USA.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

15749440

Citation

Browne, Christopher, et al. "Patellofemoral Forces After Total Knee Arthroplasty: Effect of Extensor Moment Arm." The Knee, vol. 12, no. 2, 2005, pp. 81-8.
Browne C, Hermida JC, Bergula A, et al. Patellofemoral forces after total knee arthroplasty: effect of extensor moment arm. Knee. 2005;12(2):81-8.
Browne, C., Hermida, J. C., Bergula, A., Colwell, C. W., & D'Lima, D. D. (2005). Patellofemoral forces after total knee arthroplasty: effect of extensor moment arm. The Knee, 12(2), 81-8.
Browne C, et al. Patellofemoral Forces After Total Knee Arthroplasty: Effect of Extensor Moment Arm. Knee. 2005;12(2):81-8. PubMed PMID: 15749440.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Patellofemoral forces after total knee arthroplasty: effect of extensor moment arm. AU - Browne,Christopher, AU - Hermida,Juan C, AU - Bergula,Arnie, AU - Colwell,Clifford W,Jr AU - D'Lima,Darryl D, PY - 2004/01/06/received PY - 2004/05/12/accepted PY - 2005/3/8/pubmed PY - 2005/6/23/medline PY - 2005/3/8/entrez SP - 81 EP - 8 JF - The Knee JO - Knee VL - 12 IS - 2 N2 - Total knee arthroplasty implant designs with larger extensor moment arms theoretically should generate lower extensor forces for the same externally applied loads. This study measured knee kinematics, quadriceps forces, and patellofemoral forces under conditions of dynamic knee extension under load in two knee designs with differing quadriceps moment arms. Six human cadaver knees were tested both before implantation and after sequential implantation with two posterior cruciate retaining designs. The extensor moment arm of the LMA (long extensor moment arm design, Scorpio, Howmedica Osteonics, Rutherford, NJ) was approximately 1 cm longer than that of the Control design (7000, Howmedica Osteonics). Quadriceps tension was measured during dynamic closed kinetic chain knee extension. Patellar compressive and shear forces were also recorded using a patellar component instrumented with a custom triaxial load transducer. Knee kinematics were monitored using a three-dimensional electromagnetic tracking device. Both designs produced similar patterns of femoral rollback and tibial rotation. Quadriceps tension was lower in the LMA design compared with the Control design. Patellofemoral compressive forces were also significantly reduced in the LMA design when compared with Control (8-18% lower at angles greater than 50 degrees flexion). The design with the longer extensor moment arm required less quadriceps force to extend the knee under load and reduced patellofemoral compressive forces. Reduced quadriceps forces may facilitate postoperative rehabilitation and activities such as stair climbing. Reduction in patellofemoral forces could reduce patellar complications such as anterior knee pain, component wear, and loosening. SN - 0968-0160 UR - https://www.unboundmedicine.com/medline/citation/15749440/Patellofemoral_forces_after_total_knee_arthroplasty:_effect_of_extensor_moment_arm_ DB - PRIME DP - Unbound Medicine ER -