Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma.
Invest Ophthalmol Vis Sci. 2005 Jul; 46(7):2433-9.IO

Abstract

PURPOSE

To compare full-threshold (FT) and SITA algorithms for standard automated perimetry (SAP) with frequency-doubling technology perimetry (FDT) in glaucoma, to help clinicians to relate results in patients who have had two or more of these tests during follow-up.

METHODS

This study was a retrospective analysis of data from a longitudinal prospective study at the University of California, San Diego. One hundred four eyes of 104 patients with glaucomatous optic neuropathy detected by optic disc stereophotographs were included. All patients had standard perimetry (SITA and FT) and FDT within 3 months of each other. Global indices, abnormality and severity using two threshold algorithms of standard perimetry were compared with FDT.

RESULTS

More eyes had normal visual fields by SAP-FT (57 eyes) than by either SAP-SITA (42 eyes) or FDT (45 eyes), although SAP-FT agreed more closely with FDT (kappa = 0.54 +/- 0.08) on the presence of a visual field defect than did SAP-SITA (kappa = 0.34 +/- 0.08). Correlations of FDT to standard perimetry global indices were similar regardless of the threshold strategy used for standard perimetry, yielding r2= 0.38-0.57 for SAP-FT with FDT, 0.36-0.54 for SAP-SITA with FDT.

CONCLUSIONS

Despite many similarities of SAP-SITA and SAP-FT, switching the standard of comparison from SAP-FT to SAP-SITA changes the relationship to FDT with regard to visual field abnormality, but not correlations of global indices. FDT detected abnormal fields in more eyes than SAP-FT. SAP-FT tended to detect a subset of eyes found abnormal by FDT. Visual field defects may be detected more often by FDT and SAP-SITA in eyes with early visual field loss, but these two tests may not agree on which eyes show field loss in patients who undergo both tests at follow-up.

Authors+Show Affiliations

Hamilton Glaucoma Center and Visual Function Laboratory, University of California at San Diego, La Jolla, California 92093-0946, USA. cboden@eyecenter.ucsd.eduNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Comparative Study
Journal Article
Research Support, N.I.H., Extramural
Research Support, Non-U.S. Gov't
Research Support, U.S. Gov't, P.H.S.

Language

eng

PubMed ID

15980232

Citation

Boden, Catherine, et al. "Relationship of SITA and Full-threshold Standard Perimetry to Frequency-doubling Technology Perimetry in Glaucoma." Investigative Ophthalmology & Visual Science, vol. 46, no. 7, 2005, pp. 2433-9.
Boden C, Pascual J, Medeiros FA, et al. Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma. Invest Ophthalmol Vis Sci. 2005;46(7):2433-9.
Boden, C., Pascual, J., Medeiros, F. A., Aihara, M., Weinreb, R. N., & Sample, P. A. (2005). Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma. Investigative Ophthalmology & Visual Science, 46(7), 2433-9.
Boden C, et al. Relationship of SITA and Full-threshold Standard Perimetry to Frequency-doubling Technology Perimetry in Glaucoma. Invest Ophthalmol Vis Sci. 2005;46(7):2433-9. PubMed PMID: 15980232.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma. AU - Boden,Catherine, AU - Pascual,John, AU - Medeiros,Felipe A, AU - Aihara,Makoto, AU - Weinreb,Robert N, AU - Sample,Pamela A, PY - 2005/6/28/pubmed PY - 2005/8/12/medline PY - 2005/6/28/entrez SP - 2433 EP - 9 JF - Investigative ophthalmology & visual science JO - Invest Ophthalmol Vis Sci VL - 46 IS - 7 N2 - PURPOSE: To compare full-threshold (FT) and SITA algorithms for standard automated perimetry (SAP) with frequency-doubling technology perimetry (FDT) in glaucoma, to help clinicians to relate results in patients who have had two or more of these tests during follow-up. METHODS: This study was a retrospective analysis of data from a longitudinal prospective study at the University of California, San Diego. One hundred four eyes of 104 patients with glaucomatous optic neuropathy detected by optic disc stereophotographs were included. All patients had standard perimetry (SITA and FT) and FDT within 3 months of each other. Global indices, abnormality and severity using two threshold algorithms of standard perimetry were compared with FDT. RESULTS: More eyes had normal visual fields by SAP-FT (57 eyes) than by either SAP-SITA (42 eyes) or FDT (45 eyes), although SAP-FT agreed more closely with FDT (kappa = 0.54 +/- 0.08) on the presence of a visual field defect than did SAP-SITA (kappa = 0.34 +/- 0.08). Correlations of FDT to standard perimetry global indices were similar regardless of the threshold strategy used for standard perimetry, yielding r2= 0.38-0.57 for SAP-FT with FDT, 0.36-0.54 for SAP-SITA with FDT. CONCLUSIONS: Despite many similarities of SAP-SITA and SAP-FT, switching the standard of comparison from SAP-FT to SAP-SITA changes the relationship to FDT with regard to visual field abnormality, but not correlations of global indices. FDT detected abnormal fields in more eyes than SAP-FT. SAP-FT tended to detect a subset of eyes found abnormal by FDT. Visual field defects may be detected more often by FDT and SAP-SITA in eyes with early visual field loss, but these two tests may not agree on which eyes show field loss in patients who undergo both tests at follow-up. SN - 0146-0404 UR - https://www.unboundmedicine.com/medline/citation/15980232/Relationship_of_SITA_and_full_threshold_standard_perimetry_to_frequency_doubling_technology_perimetry_in_glaucoma_ L2 - https://iovs.arvojournals.org/article.aspx?doi=10.1167/iovs.04-1108 DB - PRIME DP - Unbound Medicine ER -