Tags

Type your tag names separated by a space and hit enter

[Capacitively coupled contactless conductivity detection in capillary electrophoresis].
Se Pu. 2005 Mar; 23(2):152-7.SP

Abstract

Capacitively coupled contactless conductivity detection (C4D) is a new detection technique has been developed in recent years and used mainly in capillary electrophoresis and microchip electrophoresis. The characteristics of C4D detector are simple in structure, easy in miniaturization and integration, and free of electrodes contamination, which are common problems in an electrochemical detection. The principles and progresses of C4D in capillary electrophoresis are reviewed.

Authors+Show Affiliations

Dalian Institute of Chemical Physics, The Chinese Academy of Sciences, Dalian 116012, China.No affiliation info available

Pub Type(s)

English Abstract
Journal Article
Research Support, Non-U.S. Gov't
Review

Language

chi

PubMed ID

16013558

Citation

Tan, Feng, and Yafeng Guan. "[Capacitively Coupled Contactless Conductivity Detection in Capillary Electrophoresis]." Se Pu = Chinese Journal of Chromatography, vol. 23, no. 2, 2005, pp. 152-7.
Tan F, Guan Y. [Capacitively coupled contactless conductivity detection in capillary electrophoresis]. Se Pu. 2005;23(2):152-7.
Tan, F., & Guan, Y. (2005). [Capacitively coupled contactless conductivity detection in capillary electrophoresis]. Se Pu = Chinese Journal of Chromatography, 23(2), 152-7.
Tan F, Guan Y. [Capacitively Coupled Contactless Conductivity Detection in Capillary Electrophoresis]. Se Pu. 2005;23(2):152-7. PubMed PMID: 16013558.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - [Capacitively coupled contactless conductivity detection in capillary electrophoresis]. AU - Tan,Feng, AU - Guan,Yafeng, PY - 2005/7/15/pubmed PY - 2010/6/3/medline PY - 2005/7/15/entrez SP - 152 EP - 7 JF - Se pu = Chinese journal of chromatography JO - Se Pu VL - 23 IS - 2 N2 - Capacitively coupled contactless conductivity detection (C4D) is a new detection technique has been developed in recent years and used mainly in capillary electrophoresis and microchip electrophoresis. The characteristics of C4D detector are simple in structure, easy in miniaturization and integration, and free of electrodes contamination, which are common problems in an electrochemical detection. The principles and progresses of C4D in capillary electrophoresis are reviewed. SN - 1000-8713 UR - https://www.unboundmedicine.com/medline/citation/16013558/[Capacitively_coupled_contactless_conductivity_detection_in_capillary_electrophoresis]_ DB - PRIME DP - Unbound Medicine ER -