Tags

Type your tag names separated by a space and hit enter

New amperometric and potentiometric immunosensors based on gold nanoparticles/tris(2,2'-bipyridyl)cobalt(III) multilayer films for hepatitis B surface antigen determinations.
Biosens Bioelectron. 2005 Oct 15; 21(4):539-48.BB

Abstract

Two generic, fast, sensitive and novel electrochemical immunosensors have been developed. Initially, a layer of plasma-polymerized Nafion film (PPF) was deposited on the platinum electrode surface, then positively charged tris(2,2'-bipyridyl)cobalt(III) (Co(bpy)(3)(3+)) and negatively charged gold nanoparticles were assembled on the PPF-modified Pt electrode by layer-by-layer technique. Finally, hepatitis B surface antibody (HBsAb) was electrostatically adsorbed on the gold nanoparticles surface. Electrochemical behavior of the {Au/Co(bpy)(3)(3+)}(n) multilayer film-modified electrodes was studied. Cyclic voltammetry, electrochemical impedance spectroscopy (EIS) were adopted to monitor the regular growth of the multilayer films. The performance and factors influencing the performance of the resulting immunosensors were studied in detail. The multilayer film-modified immunosensor was used for hepatitis B surface antigen (HBsAg) determination via the amperometric and potentiometric immunosensor systems, and both systems provided the same linear ranges from 0.05 to 4.5 microg/mL with different detection limits for the amperometric system 0.005 microg/mL and for the potentiometric system 0.015 microg/mL. The immunosensors were used to analyse HBsAg in human serum samples. Analytical results of clinical samples show that the developed immunoassay is comparable with the enzyme-linked immunosorbent assays (ELISAs) method, implying a promising alternative approach for detecting HBsAg in the clinical diagnosis. In addition, the multilayer films also showed better stability for 1 month at least.

Authors+Show Affiliations

Chongqing Key Laboratory of Analytical Chemistry, College of Chemistry and Chemical Engineering, Southwest China Normal University, Chongqing 400715, China. yuanruo@swnu.edu.cnNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Evaluation Study
Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

16202866

Citation

Tang, Dianping, et al. "New Amperometric and Potentiometric Immunosensors Based On Gold nanoparticles/tris(2,2'-bipyridyl)cobalt(III) Multilayer Films for Hepatitis B Surface Antigen Determinations." Biosensors & Bioelectronics, vol. 21, no. 4, 2005, pp. 539-48.
Tang D, Yuan R, Chai Y, et al. New amperometric and potentiometric immunosensors based on gold nanoparticles/tris(2,2'-bipyridyl)cobalt(III) multilayer films for hepatitis B surface antigen determinations. Biosens Bioelectron. 2005;21(4):539-48.
Tang, D., Yuan, R., Chai, Y., Fu, Y., Dai, J., Liu, Y., & Zhong, X. (2005). New amperometric and potentiometric immunosensors based on gold nanoparticles/tris(2,2'-bipyridyl)cobalt(III) multilayer films for hepatitis B surface antigen determinations. Biosensors & Bioelectronics, 21(4), 539-48.
Tang D, et al. New Amperometric and Potentiometric Immunosensors Based On Gold nanoparticles/tris(2,2'-bipyridyl)cobalt(III) Multilayer Films for Hepatitis B Surface Antigen Determinations. Biosens Bioelectron. 2005 Oct 15;21(4):539-48. PubMed PMID: 16202866.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - New amperometric and potentiometric immunosensors based on gold nanoparticles/tris(2,2'-bipyridyl)cobalt(III) multilayer films for hepatitis B surface antigen determinations. AU - Tang,Dianping, AU - Yuan,Ruo, AU - Chai,Yaqin, AU - Fu,Yingzi, AU - Dai,Jianyuan, AU - Liu,Yan, AU - Zhong,Xia, PY - 2004/10/23/received PY - 2004/11/27/revised PY - 2004/11/30/accepted PY - 2005/10/6/pubmed PY - 2006/2/16/medline PY - 2005/10/6/entrez SP - 539 EP - 48 JF - Biosensors & bioelectronics JO - Biosens Bioelectron VL - 21 IS - 4 N2 - Two generic, fast, sensitive and novel electrochemical immunosensors have been developed. Initially, a layer of plasma-polymerized Nafion film (PPF) was deposited on the platinum electrode surface, then positively charged tris(2,2'-bipyridyl)cobalt(III) (Co(bpy)(3)(3+)) and negatively charged gold nanoparticles were assembled on the PPF-modified Pt electrode by layer-by-layer technique. Finally, hepatitis B surface antibody (HBsAb) was electrostatically adsorbed on the gold nanoparticles surface. Electrochemical behavior of the {Au/Co(bpy)(3)(3+)}(n) multilayer film-modified electrodes was studied. Cyclic voltammetry, electrochemical impedance spectroscopy (EIS) were adopted to monitor the regular growth of the multilayer films. The performance and factors influencing the performance of the resulting immunosensors were studied in detail. The multilayer film-modified immunosensor was used for hepatitis B surface antigen (HBsAg) determination via the amperometric and potentiometric immunosensor systems, and both systems provided the same linear ranges from 0.05 to 4.5 microg/mL with different detection limits for the amperometric system 0.005 microg/mL and for the potentiometric system 0.015 microg/mL. The immunosensors were used to analyse HBsAg in human serum samples. Analytical results of clinical samples show that the developed immunoassay is comparable with the enzyme-linked immunosorbent assays (ELISAs) method, implying a promising alternative approach for detecting HBsAg in the clinical diagnosis. In addition, the multilayer films also showed better stability for 1 month at least. SN - 0956-5663 UR - https://www.unboundmedicine.com/medline/citation/16202866/New_amperometric_and_potentiometric_immunosensors_based_on_gold_nanoparticles/tris_22'_bipyridyl_cobalt_III__multilayer_films_for_hepatitis_B_surface_antigen_determinations_ DB - PRIME DP - Unbound Medicine ER -