[Determination of hedychenone in Hedychium yunnanense].Zhongguo Zhong Yao Za Zhi. 2005 Oct; 30(20):1593-5.ZZ
Abstract
OBJECTIVE
To establish an HPLC method for determination of hedychenone in Hedychium yunnanense.
METHOD
C18 Chromatographic column was used, acetonitrile-water (9:1) as mobile phase, at flow rate of 1.0 mL x min(-1): The wavelength for detection was 235 nm.
RESULT
The linear range of hedychenone was 5.92-29.6 microg x mL(-1)(r = 0.9999). The average recovery was 99.0%, RSD of precision was less than 2%.
CONCLUSION
The method is simple, effective and feasible, and can be used to evaluate the quality of the herb.
MeSH
Pub Type(s)
English Abstract
Journal Article
Language
chi
PubMed ID
16422540
Citation
Yan, Qi-xin, et al. "[Determination of Hedychenone in Hedychium Yunnanense]." Zhongguo Zhong Yao Za Zhi = Zhongguo Zhongyao Zazhi = China Journal of Chinese Materia Medica, vol. 30, no. 20, 2005, pp. 1593-5.
Yan QX, Ye XW, Zhao Q, et al. [Determination of hedychenone in Hedychium yunnanense]. Zhongguo Zhong Yao Za Zhi. 2005;30(20):1593-5.
Yan, Q. X., Ye, X. W., Zhao, Q., Zhao, J. H., & Lin, Y. C. (2005). [Determination of hedychenone in Hedychium yunnanense]. Zhongguo Zhong Yao Za Zhi = Zhongguo Zhongyao Zazhi = China Journal of Chinese Materia Medica, 30(20), 1593-5.
Yan QX, et al. [Determination of Hedychenone in Hedychium Yunnanense]. Zhongguo Zhong Yao Za Zhi. 2005;30(20):1593-5. PubMed PMID: 16422540.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - [Determination of hedychenone in Hedychium yunnanense].
AU - Yan,Qi-xin,
AU - Ye,Xiao-wen,
AU - Zhao,Qing,
AU - Zhao,Jin-hua,
AU - Lin,Yong-cheng,
PY - 2006/1/21/pubmed
PY - 2007/3/1/medline
PY - 2006/1/21/entrez
SP - 1593
EP - 5
JF - Zhongguo Zhong yao za zhi = Zhongguo zhongyao zazhi = China journal of Chinese materia medica
JO - Zhongguo Zhong Yao Za Zhi
VL - 30
IS - 20
N2 - OBJECTIVE: To establish an HPLC method for determination of hedychenone in Hedychium yunnanense. METHOD: C18 Chromatographic column was used, acetonitrile-water (9:1) as mobile phase, at flow rate of 1.0 mL x min(-1): The wavelength for detection was 235 nm. RESULT: The linear range of hedychenone was 5.92-29.6 microg x mL(-1)(r = 0.9999). The average recovery was 99.0%, RSD of precision was less than 2%. CONCLUSION: The method is simple, effective and feasible, and can be used to evaluate the quality of the herb.
SN - 1001-5302
UR - https://www.unboundmedicine.com/medline/citation/16422540/[Determination_of_hedychenone_in_Hedychium_yunnanense]_
DB - PRIME
DP - Unbound Medicine
ER -