[A novel light-emitting diode-induced fluorescence detector for micro-scale flow analysis system].
Guang Pu Xue Yu Guang Pu Fen Xi. 2005 Dec; 25(12):1995-7.GP

Abstract

A compact light-emitting diode-induced fluorescence detector based on collinear scheme is described. The detector was assembled by all-solid-state optical-electronic components and easily coupled with micro-scale flow analysis system by on-column detection mode. Fluorescein isothiocyanate (FITC) and FITC-labeled amino acids were used as test analytes to evaluate the detector performance by capillary electrophoresis and flow injection analysis techniques. The concentration limit of detection was 10(-8) mol x L(-1) for FITC-labeled phenylalanine at a signal-to-noise ratio (S/N) of 3 (on-column, 0.05 mm i.d.). The system exhibited a good linear response in the range of 1 x 10(-7) -2 x 10(-5) mol x L(-1) (r2 = 0.999). The relative standard deviation (RSD) of 6 repetitive injections on peak heights is less than 3%.

Authors+Show Affiliations

Dalian Institute of Chemical Physics, The Chinese Academy of Sciences, Dalian 116012, China.No affiliation info availableNo affiliation info available

Pub Type(s)

English Abstract
Journal Article

Language

chi

PubMed ID

16544490

Citation

Yang, Bing-Cheng, et al. "[A Novel Light-emitting Diode-induced Fluorescence Detector for Micro-scale Flow Analysis System]." Guang Pu Xue Yu Guang Pu Fen Xi = Guang Pu, vol. 25, no. 12, 2005, pp. 1995-7.
Yang BC, Tan F, Guan YF. [A novel light-emitting diode-induced fluorescence detector for micro-scale flow analysis system]. Guang Pu Xue Yu Guang Pu Fen Xi. 2005;25(12):1995-7.
Yang, B. C., Tan, F., & Guan, Y. F. (2005). [A novel light-emitting diode-induced fluorescence detector for micro-scale flow analysis system]. Guang Pu Xue Yu Guang Pu Fen Xi = Guang Pu, 25(12), 1995-7.
Yang BC, Tan F, Guan YF. [A Novel Light-emitting Diode-induced Fluorescence Detector for Micro-scale Flow Analysis System]. Guang Pu Xue Yu Guang Pu Fen Xi. 2005;25(12):1995-7. PubMed PMID: 16544490.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - [A novel light-emitting diode-induced fluorescence detector for micro-scale flow analysis system]. AU - Yang,Bing-Cheng, AU - Tan,Feng, AU - Guan,Ya-Feng, PY - 2006/3/21/pubmed PY - 2006/3/21/medline PY - 2006/3/21/entrez SP - 1995 EP - 7 JF - Guang pu xue yu guang pu fen xi = Guang pu JO - Guang Pu Xue Yu Guang Pu Fen Xi VL - 25 IS - 12 N2 - A compact light-emitting diode-induced fluorescence detector based on collinear scheme is described. The detector was assembled by all-solid-state optical-electronic components and easily coupled with micro-scale flow analysis system by on-column detection mode. Fluorescein isothiocyanate (FITC) and FITC-labeled amino acids were used as test analytes to evaluate the detector performance by capillary electrophoresis and flow injection analysis techniques. The concentration limit of detection was 10(-8) mol x L(-1) for FITC-labeled phenylalanine at a signal-to-noise ratio (S/N) of 3 (on-column, 0.05 mm i.d.). The system exhibited a good linear response in the range of 1 x 10(-7) -2 x 10(-5) mol x L(-1) (r2 = 0.999). The relative standard deviation (RSD) of 6 repetitive injections on peak heights is less than 3%. SN - 1000-0593 UR - https://www.unboundmedicine.com/medline/citation/16544490/[A_novel_light_emitting_diode_induced_fluorescence_detector_for_micro_scale_flow_analysis_system]_ DB - PRIME DP - Unbound Medicine ER -
Try the Free App:
Prime PubMed app for iOS iPhone iPad
Prime PubMed app for Android
Prime PubMed is provided
free to individuals by:
Unbound Medicine.