Abstract

The potential of capillaries noncovalently coated with a bilayer of oppositely charged polymers for the analysis of peptides by CE-MS was investigated. Bilayer coatings were produced by subsequently rinsing fused-silica capillaries with a solution of Polybrene (PB) and poly(vinyl sulfonate) (PVS). The PB-PVS coating showed to be fully compatible with MS detection causing no ionization suppression or background signals. The bilayer coating provided a considerable EOF at low pH, thereby facilitating the fast separation of peptides using a BGE of formic acid (pH 2.5). Under optimized CE-MS conditions, for enkephalin peptides high separation efficiencies were obtained with plate numbers in the range of 300,000-500,000. It is demonstrated that both the cancellation of the hydrodynamic capillary flow induced by the nebulizer gas and a sufficiently high-data acquisition rate are crucial for achieving these efficiencies. The overall performance of the CE-MS system using PB-PVS-coated capillaries was evaluated by the analysis of a tryptic digest of cytochrome c. The system provided an efficient separation of the peptide mixture, which could be effectively monitored by MS/MS detection allowing identification of at least 13 peptides within a time interval of 1.5 min. In addition, the PB-PVS coating proved to be very consistent yielding stable CE-MS patterns with highly favorable migration time reproducibilities (RSDs < 1% over a 3-day period).

Authors+Show Affiliations

Department of Biomedical Analysis, Utrecht University, The Netherlands.No affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Evaluation Study
Journal Article

Language

eng

PubMed ID

16736451

Citation

Catai, Jonatan R., et al. "Efficient and Highly Reproducible Capillary Electrophoresis-mass Spectrometry of Peptides Using Polybrene-poly(vinyl Sulfonate)-coated Capillaries." Electrophoresis, vol. 27, no. 11, 2006, pp. 2091-9.
Catai JR, Toraño JS, de Jong GJ, et al. Efficient and highly reproducible capillary electrophoresis-mass spectrometry of peptides using Polybrene-poly(vinyl sulfonate)-coated capillaries. Electrophoresis. 2006;27(11):2091-9.
Catai, J. R., Toraño, J. S., de Jong, G. J., & Somsen, G. W. (2006). Efficient and highly reproducible capillary electrophoresis-mass spectrometry of peptides using Polybrene-poly(vinyl sulfonate)-coated capillaries. Electrophoresis, 27(11), 2091-9.
Catai JR, et al. Efficient and Highly Reproducible Capillary Electrophoresis-mass Spectrometry of Peptides Using Polybrene-poly(vinyl Sulfonate)-coated Capillaries. Electrophoresis. 2006;27(11):2091-9. PubMed PMID: 16736451.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Efficient and highly reproducible capillary electrophoresis-mass spectrometry of peptides using Polybrene-poly(vinyl sulfonate)-coated capillaries. AU - Catai,Jonatan R, AU - Toraño,Javier Sastre, AU - de Jong,Gerhardus J, AU - Somsen,Govert W, PY - 2006/6/1/pubmed PY - 2006/9/14/medline PY - 2006/6/1/entrez SP - 2091 EP - 9 JF - Electrophoresis JO - Electrophoresis VL - 27 IS - 11 N2 - The potential of capillaries noncovalently coated with a bilayer of oppositely charged polymers for the analysis of peptides by CE-MS was investigated. Bilayer coatings were produced by subsequently rinsing fused-silica capillaries with a solution of Polybrene (PB) and poly(vinyl sulfonate) (PVS). The PB-PVS coating showed to be fully compatible with MS detection causing no ionization suppression or background signals. The bilayer coating provided a considerable EOF at low pH, thereby facilitating the fast separation of peptides using a BGE of formic acid (pH 2.5). Under optimized CE-MS conditions, for enkephalin peptides high separation efficiencies were obtained with plate numbers in the range of 300,000-500,000. It is demonstrated that both the cancellation of the hydrodynamic capillary flow induced by the nebulizer gas and a sufficiently high-data acquisition rate are crucial for achieving these efficiencies. The overall performance of the CE-MS system using PB-PVS-coated capillaries was evaluated by the analysis of a tryptic digest of cytochrome c. The system provided an efficient separation of the peptide mixture, which could be effectively monitored by MS/MS detection allowing identification of at least 13 peptides within a time interval of 1.5 min. In addition, the PB-PVS coating proved to be very consistent yielding stable CE-MS patterns with highly favorable migration time reproducibilities (RSDs < 1% over a 3-day period). SN - 0173-0835 UR - https://www.unboundmedicine.com/medline/citation/16736451/Efficient_and_highly_reproducible_capillary_electrophoresis_mass_spectrometry_of_peptides_using_Polybrene_poly_vinyl_sulfonate__coated_capillaries_ DB - PRIME DP - Unbound Medicine ER -