Simultaneous detection of creatine and creatinine using a sequential injection analysis/biosensor system.Prep Biochem Biotechnol. 2006; 36(4):287-96.PB
Abstract
Carbon paste based biosensors for the determination of creatine and creatinine have been integrated into a sequential injection system. Applying the multi-enzyme sequence of creatininase (CA), and/or creatinase (CI) and sarcosine oxidase (SO), hydrogen peroxide has been detected amperometrically. The linear concentration ranges are of pmol/L to nmol/L magnitude, with very low limits of detection. The proposed SIA system can be utilized reliably for the on-line simultaneous detection of creatine and creatinine in pharmaceutical products, as well as in serum samples, with a rate of 34 samples per hour and RSD values better than 0.16% (n=10).
Links
MeSH
Pub Type(s)
Journal Article
Language
eng
PubMed ID
16971300
Citation
Stefan-van Staden, Raluca-Ioana, et al. "Simultaneous Detection of Creatine and Creatinine Using a Sequential Injection Analysis/biosensor System." Preparative Biochemistry & Biotechnology, vol. 36, no. 4, 2006, pp. 287-96.
Stefan-van Staden RI, Bokretsion RG, van Staden JF, et al. Simultaneous detection of creatine and creatinine using a sequential injection analysis/biosensor system. Prep Biochem Biotechnol. 2006;36(4):287-96.
Stefan-van Staden, R. I., Bokretsion, R. G., van Staden, J. F., & Aboul-Enein, H. Y. (2006). Simultaneous detection of creatine and creatinine using a sequential injection analysis/biosensor system. Preparative Biochemistry & Biotechnology, 36(4), 287-96.
Stefan-van Staden RI, et al. Simultaneous Detection of Creatine and Creatinine Using a Sequential Injection Analysis/biosensor System. Prep Biochem Biotechnol. 2006;36(4):287-96. PubMed PMID: 16971300.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - Simultaneous detection of creatine and creatinine using a sequential injection analysis/biosensor system.
AU - Stefan-van Staden,Raluca-Ioana,
AU - Bokretsion,Rahel Girmai,
AU - van Staden,Jacobus F,
AU - Aboul-Enein,Hassan Y,
PY - 2006/9/15/pubmed
PY - 2006/12/23/medline
PY - 2006/9/15/entrez
SP - 287
EP - 96
JF - Preparative biochemistry & biotechnology
JO - Prep Biochem Biotechnol
VL - 36
IS - 4
N2 - Carbon paste based biosensors for the determination of creatine and creatinine have been integrated into a sequential injection system. Applying the multi-enzyme sequence of creatininase (CA), and/or creatinase (CI) and sarcosine oxidase (SO), hydrogen peroxide has been detected amperometrically. The linear concentration ranges are of pmol/L to nmol/L magnitude, with very low limits of detection. The proposed SIA system can be utilized reliably for the on-line simultaneous detection of creatine and creatinine in pharmaceutical products, as well as in serum samples, with a rate of 34 samples per hour and RSD values better than 0.16% (n=10).