Abstract
OBJECTIVE
To establish the RP-HPLC fingerprint analysis for the quality control of Cortex Periplocae.
METHODS
HPLC fingerprint and analysis method of Cortex Periplocae were studied. Kromasil C18 column (250 mm x 4.6 mm, 5 microm) was used, with mixture of acetonitrile and 0.025% phosphate solution as mobile phase in a gradient mode. The flow rate was 1.0 ml/min. The wavelength of measurement was 220 nm. 15 Batches of Cortex Periplocae were determined.
RESULTS
The 15 samples were classified as 4 clusters by cluster analysis and the 6 superior in producing area samples were confirmed to establish the mutual model. The samples' quality was assessed by "Similarity Evaluation System for Chromatographic Fingerprint of TCM 2004".
CONCLUSION
The method is simple and reliable. It can be used to evaluate and control the quality of Cortex Periplocae conveniently.
TY - JOUR
T1 - [Establishment of RP-HPLC fingerprint for quality assessment of Cortex Periplocae].
AU - Li,Dan-yi,
AU - Wang,Ting-ting,
AU - Chen,Xiao-hui,
AU - Bi,Kai-shun,
PY - 2006/10/25/pubmed
PY - 2007/5/10/medline
PY - 2006/10/25/entrez
SP - 715
EP - 7
JF - Zhong yao cai = Zhongyaocai = Journal of Chinese medicinal materials
JO - Zhong Yao Cai
VL - 29
IS - 7
N2 - OBJECTIVE: To establish the RP-HPLC fingerprint analysis for the quality control of Cortex Periplocae. METHODS: HPLC fingerprint and analysis method of Cortex Periplocae were studied. Kromasil C18 column (250 mm x 4.6 mm, 5 microm) was used, with mixture of acetonitrile and 0.025% phosphate solution as mobile phase in a gradient mode. The flow rate was 1.0 ml/min. The wavelength of measurement was 220 nm. 15 Batches of Cortex Periplocae were determined. RESULTS: The 15 samples were classified as 4 clusters by cluster analysis and the 6 superior in producing area samples were confirmed to establish the mutual model. The samples' quality was assessed by "Similarity Evaluation System for Chromatographic Fingerprint of TCM 2004". CONCLUSION: The method is simple and reliable. It can be used to evaluate and control the quality of Cortex Periplocae conveniently.
SN - 1001-4454
UR - https://www.unboundmedicine.com/medline/citation/17059012/[Establishment_of_RP_HPLC_fingerprint_for_quality_assessment_of_Cortex_Periplocae]_
DB - PRIME
DP - Unbound Medicine
ER -