Tags

Type your tag names separated by a space and hit enter

Simultaneous quantification of five anthraquinones in rat plasma by high-performance liquid chromatography with fluorescence detection.
Biomed Chromatogr. 2007 May; 21(5):502-7.BC

Abstract

A sensitive high-performance liquid chromatographic method with fluorescence detection (excitation 435 and emission 515 nm) was established and validated for quantification of five anthraquinones (aloe-emodin, rhein, emodin, chrysophanol and physcion) in rat plasma. Following a single-step liquid-liquid extraction, the analytes and internal standard (1,8-dihydroxyanthraquinone) were separated on a reversed-phase C(18) column with water-phosphoric acid-methanol as mobile phase at a flow rate of 1 mL/min. The linear ranges of the calibration curves were 6.5-1300 ng/mL for aloe-emodin, 20-4000 ng/mL for rhein, 40-8000 ng/mL for emodin, 15-3000 ng/mL for chrysophanol and 13-2600 ng/mL for physcion. The lower limit of quantification was 6.5 ng/mL for aloe-emodin, 20 ng/mL for rhein, 40 ng/mL for emodin, 15 ng/mL for chrysophanol and 13 ng/mL for physcion. The mean accuracy was 94.3-105.1% for aloe-emodin, 90.3-108.8% for rhein, 92.6-106.7% for emodin, 95.8-103.8% for chrysophanol and 98.7-101.2% for physcion. The within-batch and between-batch precisions were < or = 5.5% and < or = 13.4%, respectively. This method is suitable for determining the five anthraquinones in plasma simultaneously and thus investigating the pharmacokinetics of anthraquinones from Xiexin decoction in rats.

Authors+Show Affiliations

College of Chinese Material Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, People's Republic of China.No affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't
Validation Study

Language

eng

PubMed ID

17294506

Citation

Yan, Dongming, and Yueming Ma. "Simultaneous Quantification of Five Anthraquinones in Rat Plasma By High-performance Liquid Chromatography With Fluorescence Detection." Biomedical Chromatography : BMC, vol. 21, no. 5, 2007, pp. 502-7.
Yan D, Ma Y. Simultaneous quantification of five anthraquinones in rat plasma by high-performance liquid chromatography with fluorescence detection. Biomed Chromatogr. 2007;21(5):502-7.
Yan, D., & Ma, Y. (2007). Simultaneous quantification of five anthraquinones in rat plasma by high-performance liquid chromatography with fluorescence detection. Biomedical Chromatography : BMC, 21(5), 502-7.
Yan D, Ma Y. Simultaneous Quantification of Five Anthraquinones in Rat Plasma By High-performance Liquid Chromatography With Fluorescence Detection. Biomed Chromatogr. 2007;21(5):502-7. PubMed PMID: 17294506.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Simultaneous quantification of five anthraquinones in rat plasma by high-performance liquid chromatography with fluorescence detection. AU - Yan,Dongming, AU - Ma,Yueming, PY - 2007/2/13/pubmed PY - 2007/6/15/medline PY - 2007/2/13/entrez SP - 502 EP - 7 JF - Biomedical chromatography : BMC JO - Biomed Chromatogr VL - 21 IS - 5 N2 - A sensitive high-performance liquid chromatographic method with fluorescence detection (excitation 435 and emission 515 nm) was established and validated for quantification of five anthraquinones (aloe-emodin, rhein, emodin, chrysophanol and physcion) in rat plasma. Following a single-step liquid-liquid extraction, the analytes and internal standard (1,8-dihydroxyanthraquinone) were separated on a reversed-phase C(18) column with water-phosphoric acid-methanol as mobile phase at a flow rate of 1 mL/min. The linear ranges of the calibration curves were 6.5-1300 ng/mL for aloe-emodin, 20-4000 ng/mL for rhein, 40-8000 ng/mL for emodin, 15-3000 ng/mL for chrysophanol and 13-2600 ng/mL for physcion. The lower limit of quantification was 6.5 ng/mL for aloe-emodin, 20 ng/mL for rhein, 40 ng/mL for emodin, 15 ng/mL for chrysophanol and 13 ng/mL for physcion. The mean accuracy was 94.3-105.1% for aloe-emodin, 90.3-108.8% for rhein, 92.6-106.7% for emodin, 95.8-103.8% for chrysophanol and 98.7-101.2% for physcion. The within-batch and between-batch precisions were < or = 5.5% and < or = 13.4%, respectively. This method is suitable for determining the five anthraquinones in plasma simultaneously and thus investigating the pharmacokinetics of anthraquinones from Xiexin decoction in rats. SN - 0269-3879 UR - https://www.unboundmedicine.com/medline/citation/17294506/Simultaneous_quantification_of_five_anthraquinones_in_rat_plasma_by_high_performance_liquid_chromatography_with_fluorescence_detection_ L2 - https://doi.org/10.1002/bmc.784 DB - PRIME DP - Unbound Medicine ER -