Tags

Type your tag names separated by a space and hit enter

Microfluidic chip accomplishing self-fluid replacement using only capillary force and its bioanalytical application.
Anal Chim Acta. 2007 Feb 28; 585(1):1-10.AC

Abstract

A polymer microfluidic chip accomplishing automated sample flow and replacement without external controls and an application of the chip for bioanalytical reaction were described. All the fluidic operations in the chip were achieved by only natural capillary flow in a time-planned sequence. For the control of the capillary flow, the geometry of the channels and chambers in the chip was designed based on theoretical considerations and numerical simulations. The microfluidic chip was made by using polymer replication techniques, which were suitable for fast and cheap fabrication. The test for a biochemical analysis, employing an enzyme (HRP)-catalyzed precipitation reaction, exhibited a good performance using the developed chip. The presented microfluidic method would be applicable to biochemical lab-on-a-chips with integrated fluid replacement steps, such as affinity elution and solution exchange during biosensor signaling.

Authors+Show Affiliations

Biosensor Team, ETRI, Daejeon 305-350, Republic of Korea.No affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

17386640

Citation

Chung, Kwang Hyo, et al. "Microfluidic Chip Accomplishing Self-fluid Replacement Using Only Capillary Force and Its Bioanalytical Application." Analytica Chimica Acta, vol. 585, no. 1, 2007, pp. 1-10.
Chung KH, Hong JW, Lee DS, et al. Microfluidic chip accomplishing self-fluid replacement using only capillary force and its bioanalytical application. Anal Chim Acta. 2007;585(1):1-10.
Chung, K. H., Hong, J. W., Lee, D. S., & Yoon, H. C. (2007). Microfluidic chip accomplishing self-fluid replacement using only capillary force and its bioanalytical application. Analytica Chimica Acta, 585(1), 1-10.
Chung KH, et al. Microfluidic Chip Accomplishing Self-fluid Replacement Using Only Capillary Force and Its Bioanalytical Application. Anal Chim Acta. 2007 Feb 28;585(1):1-10. PubMed PMID: 17386640.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Microfluidic chip accomplishing self-fluid replacement using only capillary force and its bioanalytical application. AU - Chung,Kwang Hyo, AU - Hong,Jung Woo, AU - Lee,Dae-Sik, AU - Yoon,Hyun C, Y1 - 2006/12/13/ PY - 2006/11/03/received PY - 2006/11/30/revised PY - 2006/12/05/accepted PY - 2007/3/28/pubmed PY - 2007/5/31/medline PY - 2007/3/28/entrez SP - 1 EP - 10 JF - Analytica chimica acta JO - Anal Chim Acta VL - 585 IS - 1 N2 - A polymer microfluidic chip accomplishing automated sample flow and replacement without external controls and an application of the chip for bioanalytical reaction were described. All the fluidic operations in the chip were achieved by only natural capillary flow in a time-planned sequence. For the control of the capillary flow, the geometry of the channels and chambers in the chip was designed based on theoretical considerations and numerical simulations. The microfluidic chip was made by using polymer replication techniques, which were suitable for fast and cheap fabrication. The test for a biochemical analysis, employing an enzyme (HRP)-catalyzed precipitation reaction, exhibited a good performance using the developed chip. The presented microfluidic method would be applicable to biochemical lab-on-a-chips with integrated fluid replacement steps, such as affinity elution and solution exchange during biosensor signaling. SN - 1873-4324 UR - https://www.unboundmedicine.com/medline/citation/17386640/Microfluidic_chip_accomplishing_self_fluid_replacement_using_only_capillary_force_and_its_bioanalytical_application_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S0003-2670(06)02337-3 DB - PRIME DP - Unbound Medicine ER -