PURPOSE

To evaluate the effects of a primary posterior continuous curvilinear capsulorhexis (PCCC) on the clinical performance of a single-piece hydrophilic acrylic intraocular lens (IOL) with haptic angulation.

SETTING

Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.

METHODS

A prospective study of 52 patients with bilateral age-related cataract was conducted. Patients had standard cataract surgery with implantation of the same IOL in both eyes. Randomly, a PCCC was created in 1 eye and the posterior capsule was left intact in the fellow eye. Assessed parameters were visual axis opacification (VAO) in eyes with a PCCC or regeneratory posterior capsule opacification (PCO) in eyes without PCCC (scale 0 to 10) in the central (3.0 mm eccentricity), intermediate (3.0 to 4.5 mm eccentricity), and peripheral (>4.5 mm eccentricity [capsulorhexis edge]) areas; neodymium:YAG (Nd:YAG) laser capsulotomy or laser polishing of ongrowing lens epithelium; anterior capsule opacification (ACO); best corrected visual acuity (BCVA); and contrast sensitivity.

RESULTS

Thirty patients completed the 2(1/2)-year follow-up. Visual axis opacification was significantly lower in the central region in the PCCC group (mean 0.5 +/- 0.7 [SD]) than PCO in the central region of the non-PCCC group (mean 1.1 +/- 1.1) (P = .02). Forty percent in the non-PCCC group had an Nd:YAG laser capsulotomy during the follow-up period; none in the PCCC group had laser polishing. There were no significant differences in ACO, SE, BCVA, or contrast sensitivity. There was no additional gain in BCVA or contrast sensitivity in eyes with a PCCC compared with eyes without a PCCC when VAO and PCO were low.

CONCLUSION

A PCCC significantly reduced PCO formation within the central 3.0 mm eccentricity as well as the need for Nd:YAG laser capsulotomy in eyes with a single-piece hydrophilic acrylic IOL with angulated haptics.

Authors+Show Affiliations

Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Randomized Controlled Trial

Language

eng

PubMed ID

17397735

Citation

Vock, Lorenz, et al. "Effect of Primary Posterior Continuous Curvilinear Capsulorhexis On Clinical Performance of ACR6D SE Single-piece Hydrophilic Acrylic Intraocular Lenses." Journal of Cataract and Refractive Surgery, vol. 33, no. 4, 2007, pp. 628-34.
Vock L, Menapace R, Stifter E, et al. Effect of primary posterior continuous curvilinear capsulorhexis on clinical performance of ACR6D SE single-piece hydrophilic acrylic intraocular lenses. J Cataract Refract Surg. 2007;33(4):628-34.
Vock, L., Menapace, R., Stifter, E., Bühl, W., & Georgopoulos, M. (2007). Effect of primary posterior continuous curvilinear capsulorhexis on clinical performance of ACR6D SE single-piece hydrophilic acrylic intraocular lenses. Journal of Cataract and Refractive Surgery, 33(4), 628-34.
Vock L, et al. Effect of Primary Posterior Continuous Curvilinear Capsulorhexis On Clinical Performance of ACR6D SE Single-piece Hydrophilic Acrylic Intraocular Lenses. J Cataract Refract Surg. 2007;33(4):628-34. PubMed PMID: 17397735.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Effect of primary posterior continuous curvilinear capsulorhexis on clinical performance of ACR6D SE single-piece hydrophilic acrylic intraocular lenses. AU - Vock,Lorenz, AU - Menapace,Rupert, AU - Stifter,Eva, AU - Bühl,Wolf, AU - Georgopoulos,Michael, PY - 2006/11/04/received PY - 2007/01/03/accepted PY - 2007/4/3/pubmed PY - 2007/6/15/medline PY - 2007/4/3/entrez SP - 628 EP - 34 JF - Journal of cataract and refractive surgery JO - J Cataract Refract Surg VL - 33 IS - 4 N2 - PURPOSE: To evaluate the effects of a primary posterior continuous curvilinear capsulorhexis (PCCC) on the clinical performance of a single-piece hydrophilic acrylic intraocular lens (IOL) with haptic angulation. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: A prospective study of 52 patients with bilateral age-related cataract was conducted. Patients had standard cataract surgery with implantation of the same IOL in both eyes. Randomly, a PCCC was created in 1 eye and the posterior capsule was left intact in the fellow eye. Assessed parameters were visual axis opacification (VAO) in eyes with a PCCC or regeneratory posterior capsule opacification (PCO) in eyes without PCCC (scale 0 to 10) in the central (3.0 mm eccentricity), intermediate (3.0 to 4.5 mm eccentricity), and peripheral (>4.5 mm eccentricity [capsulorhexis edge]) areas; neodymium:YAG (Nd:YAG) laser capsulotomy or laser polishing of ongrowing lens epithelium; anterior capsule opacification (ACO); best corrected visual acuity (BCVA); and contrast sensitivity. RESULTS: Thirty patients completed the 2(1/2)-year follow-up. Visual axis opacification was significantly lower in the central region in the PCCC group (mean 0.5 +/- 0.7 [SD]) than PCO in the central region of the non-PCCC group (mean 1.1 +/- 1.1) (P = .02). Forty percent in the non-PCCC group had an Nd:YAG laser capsulotomy during the follow-up period; none in the PCCC group had laser polishing. There were no significant differences in ACO, SE, BCVA, or contrast sensitivity. There was no additional gain in BCVA or contrast sensitivity in eyes with a PCCC compared with eyes without a PCCC when VAO and PCO were low. CONCLUSION: A PCCC significantly reduced PCO formation within the central 3.0 mm eccentricity as well as the need for Nd:YAG laser capsulotomy in eyes with a single-piece hydrophilic acrylic IOL with angulated haptics. SN - 0886-3350 UR - https://www.unboundmedicine.com/medline/citation/17397735/Effect_of_primary_posterior_continuous_curvilinear_capsulorhexis_on_clinical_performance_of_ACR6D_SE_single_piece_hydrophilic_acrylic_intraocular_lenses_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S0886-3350(07)00084-3 DB - PRIME DP - Unbound Medicine ER -