Tags

Type your tag names separated by a space and hit enter

Computer-aided design/computer-aided manufacturing surgical guidance for placement of dental implants: case report.
Implant Dent. 2007 Jun; 16(2):123-30.ID

Abstract

Dental implant rehabilitation faces increasing prosthetic and esthetic demands, requiring precise surgical planning and placement. Presurgical treatment evaluation can now be accomplished using 3-dimensional computed tomography imaging. Although software has been developed to assist in implant selection and localization, transferring this information to the surgical field has remained a difficult task. Over the last few years, computer-aided design and manufacturing have made it possible to use data from computed tomography in order to transfer virtual implant placement to the surgery. One of these techniques utilizes a small computer-driven drilling mechanism that transfers implant planning on a laboratory model. This novel approach may be advantageous once available in dental laboratories and/or offices. This report presents the method and, for the first time, illustrates it with a fully edentulous advanced clinical case. Resulting clinical benefits over traditional procedures are discussed.

Authors+Show Affiliations

Department of Biomaterial Sciences, Graduate Prosthodontics, University of Michigan School of Dentistry, 1011 North University Avenue, Ann Arbor, MI 48109, USA.No affiliation info availableNo affiliation info available

Pub Type(s)

Case Reports
Journal Article

Language

eng

PubMed ID

17563502

Citation

Wong, Natalie Y., et al. "Computer-aided Design/computer-aided Manufacturing Surgical Guidance for Placement of Dental Implants: Case Report." Implant Dentistry, vol. 16, no. 2, 2007, pp. 123-30.
Wong NY, Huffer-Charchut H, Sarment DP. Computer-aided design/computer-aided manufacturing surgical guidance for placement of dental implants: case report. Implant Dent. 2007;16(2):123-30.
Wong, N. Y., Huffer-Charchut, H., & Sarment, D. P. (2007). Computer-aided design/computer-aided manufacturing surgical guidance for placement of dental implants: case report. Implant Dentistry, 16(2), 123-30.
Wong NY, Huffer-Charchut H, Sarment DP. Computer-aided Design/computer-aided Manufacturing Surgical Guidance for Placement of Dental Implants: Case Report. Implant Dent. 2007;16(2):123-30. PubMed PMID: 17563502.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Computer-aided design/computer-aided manufacturing surgical guidance for placement of dental implants: case report. AU - Wong,Natalie Y, AU - Huffer-Charchut,Heather, AU - Sarment,David P, PY - 2007/6/15/pubmed PY - 2007/9/14/medline PY - 2007/6/15/entrez SP - 123 EP - 30 JF - Implant dentistry JO - Implant Dent VL - 16 IS - 2 N2 - Dental implant rehabilitation faces increasing prosthetic and esthetic demands, requiring precise surgical planning and placement. Presurgical treatment evaluation can now be accomplished using 3-dimensional computed tomography imaging. Although software has been developed to assist in implant selection and localization, transferring this information to the surgical field has remained a difficult task. Over the last few years, computer-aided design and manufacturing have made it possible to use data from computed tomography in order to transfer virtual implant placement to the surgery. One of these techniques utilizes a small computer-driven drilling mechanism that transfers implant planning on a laboratory model. This novel approach may be advantageous once available in dental laboratories and/or offices. This report presents the method and, for the first time, illustrates it with a fully edentulous advanced clinical case. Resulting clinical benefits over traditional procedures are discussed. SN - 1056-6163 UR - https://www.unboundmedicine.com/medline/citation/17563502/Computer_aided_design/computer_aided_manufacturing_surgical_guidance_for_placement_of_dental_implants:_case_report_ L2 - https://doi.org/10.1097/ID.0b013e31805008d3 DB - PRIME DP - Unbound Medicine ER -