Quantitative determination of azithromycin in human plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry and its application in a pharmacokinetic study.
J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Aug 15; 855(2):255-61.JC

Abstract

A selective, rapid and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the quantitative determination of azithromycin in human plasma and its application in a pharmacokinetic study. With roxithromycin as internal standard, sample pretreatment involved a one-step extraction with diethyl ether of 0.5 mL plasma. The analysis was carried out on an ACQUITY UPLC BEH C(18) column (50 mm x 2.1 mm, i.d., 1.7 microm) with gradient elution at flow rate of 0.35 mL/min. The mobile phase was 50 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI). Linear calibration curves were obtained in the concentration range of 1-1000 ng/mL, with a lower limit of quantification of 1 ng/mL. The intra- and inter-day precision (RSD) values were below 15% and accuracy (RE) was -1.3% to 5.7% at all QC levels. The method was applicable to clinical pharmacokinetic study of azithromycin in healthy volunteers following oral administration.

Authors+Show Affiliations

Department of Analytical Chemistry, Shenyang Pharmaceutical University, Shenyang, PR China.No affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Evaluation Study
Journal Article

Language

eng

PubMed ID

17574935

Citation

Chen, Lingyun, et al. "Quantitative Determination of Azithromycin in Human Plasma By Ultra Performance Liquid Chromatography-electrospray Ionization Mass Spectrometry and Its Application in a Pharmacokinetic Study." Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences, vol. 855, no. 2, 2007, pp. 255-61.
Chen L, Qin F, Ma Y, et al. Quantitative determination of azithromycin in human plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry and its application in a pharmacokinetic study. J Chromatogr B Analyt Technol Biomed Life Sci. 2007;855(2):255-61.
Chen, L., Qin, F., Ma, Y., & Li, F. (2007). Quantitative determination of azithromycin in human plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry and its application in a pharmacokinetic study. Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences, 855(2), 255-61.
Chen L, et al. Quantitative Determination of Azithromycin in Human Plasma By Ultra Performance Liquid Chromatography-electrospray Ionization Mass Spectrometry and Its Application in a Pharmacokinetic Study. J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Aug 15;855(2):255-61. PubMed PMID: 17574935.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Quantitative determination of azithromycin in human plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry and its application in a pharmacokinetic study. AU - Chen,Lingyun, AU - Qin,Feng, AU - Ma,Yuanyuan, AU - Li,Famei, Y1 - 2007/05/26/ PY - 2007/01/31/received PY - 2007/05/08/revised PY - 2007/05/11/accepted PY - 2007/6/19/pubmed PY - 2007/12/7/medline PY - 2007/6/19/entrez SP - 255 EP - 61 JF - Journal of chromatography. B, Analytical technologies in the biomedical and life sciences JO - J Chromatogr B Analyt Technol Biomed Life Sci VL - 855 IS - 2 N2 - A selective, rapid and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the quantitative determination of azithromycin in human plasma and its application in a pharmacokinetic study. With roxithromycin as internal standard, sample pretreatment involved a one-step extraction with diethyl ether of 0.5 mL plasma. The analysis was carried out on an ACQUITY UPLC BEH C(18) column (50 mm x 2.1 mm, i.d., 1.7 microm) with gradient elution at flow rate of 0.35 mL/min. The mobile phase was 50 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI). Linear calibration curves were obtained in the concentration range of 1-1000 ng/mL, with a lower limit of quantification of 1 ng/mL. The intra- and inter-day precision (RSD) values were below 15% and accuracy (RE) was -1.3% to 5.7% at all QC levels. The method was applicable to clinical pharmacokinetic study of azithromycin in healthy volunteers following oral administration. SN - 1570-0232 UR - https://www.unboundmedicine.com/medline/citation/17574935/Quantitative_determination_of_azithromycin_in_human_plasma_by_ultra_performance_liquid_chromatography_electrospray_ionization_mass_spectrometry_and_its_application_in_a_pharmacokinetic_study_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S1570-0232(07)00377-7 DB - PRIME DP - Unbound Medicine ER -