PURPOSE

To determine the accuracy of frequency compounding (FC) in detection and characterisation of breast lesions by ultrasound (US) and to assess the image quality in direct comparison with tissue harmonic imaging (THI).

MATERIALS AND METHODS

A total of 60 breast lesions were examined; these were malignant in 39 cases and benign in 21 as confirmed by histology of core biopsy specimens (Aplio 80, Toshiba, Otawara, Japan). A total of 120 freeze frames, 60 B-mode scans with THI and 60 scans with FC were assessed by three independent examiners, who determined the presence of pathology on a scale of 1 to 5 using established criteria (BI-RADS classification). Image quality of each technique was rated on a ranking scale of - 2 (FC clearly superior to THI), - 1 (FC slightly superior to THI), 0 (identical), + 1 (THI slightly superior to FC), to + 2 (THI clearly superior to FC). The different US techniques were compared in terms of image quality and diagnostic accuracy using Mann Whitney U test and ROC analysis.

RESULTS

The results for image quality were as follows: - 0.56 +/- 0.71. In 56 % of the images FC was superior to THI, both techniques were identical in 37 % of cases, and in only 7 % THI was superior to FC. The following AUCs (Area under Curve, presence of pathology) were calculated: 0.945 and 0.969 for THI and FC, respectively (not significant). The two US techniques had comparable sensitivity (FC/THI 100/98 %) and specificity (FC/THI 76/74 %).

CONCLUSION

Altogether, the diagnostic value of FC was comparable to that of THI with only slight differences. For ultrasound examinations of breast lesions, FC improves the image quality and conspicuity of pathology.

Authors+Show Affiliations

Klinik für Gynäkologie und Geburtshilfe, Universität Berlin. anke.thomas@charite.deNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

ger

PubMed ID

17602368

Citation

Thomas, A, et al. "[Image Quality and Characterisation of Sonographically Detected Breast Lesions: Comparison of Tissue Harmonic Imaging Alone and in Combination With Frequency Compounding]." Ultraschall in Der Medizin (Stuttgart, Germany : 1980), vol. 28, no. 4, 2007, pp. 387-93.
Thomas A, Filimonow S, Slowinski T, et al. [Image quality and characterisation of sonographically detected breast lesions: comparison of tissue harmonic imaging alone and in combination with frequency compounding]. Ultraschall Med. 2007;28(4):387-93.
Thomas, A., Filimonow, S., Slowinski, T., & Fischer, T. (2007). [Image quality and characterisation of sonographically detected breast lesions: comparison of tissue harmonic imaging alone and in combination with frequency compounding]. Ultraschall in Der Medizin (Stuttgart, Germany : 1980), 28(4), 387-93.
Thomas A, et al. [Image Quality and Characterisation of Sonographically Detected Breast Lesions: Comparison of Tissue Harmonic Imaging Alone and in Combination With Frequency Compounding]. Ultraschall Med. 2007;28(4):387-93. PubMed PMID: 17602368.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - [Image quality and characterisation of sonographically detected breast lesions: comparison of tissue harmonic imaging alone and in combination with frequency compounding]. AU - Thomas,A, AU - Filimonow,S, AU - Slowinski,T, AU - Fischer,T, Y1 - 2007/06/29/ PY - 2007/7/3/pubmed PY - 2007/10/13/medline PY - 2007/7/3/entrez SP - 387 EP - 93 JF - Ultraschall in der Medizin (Stuttgart, Germany : 1980) JO - Ultraschall Med VL - 28 IS - 4 N2 - PURPOSE: To determine the accuracy of frequency compounding (FC) in detection and characterisation of breast lesions by ultrasound (US) and to assess the image quality in direct comparison with tissue harmonic imaging (THI). MATERIALS AND METHODS: A total of 60 breast lesions were examined; these were malignant in 39 cases and benign in 21 as confirmed by histology of core biopsy specimens (Aplio 80, Toshiba, Otawara, Japan). A total of 120 freeze frames, 60 B-mode scans with THI and 60 scans with FC were assessed by three independent examiners, who determined the presence of pathology on a scale of 1 to 5 using established criteria (BI-RADS classification). Image quality of each technique was rated on a ranking scale of - 2 (FC clearly superior to THI), - 1 (FC slightly superior to THI), 0 (identical), + 1 (THI slightly superior to FC), to + 2 (THI clearly superior to FC). The different US techniques were compared in terms of image quality and diagnostic accuracy using Mann Whitney U test and ROC analysis. RESULTS: The results for image quality were as follows: - 0.56 +/- 0.71. In 56 % of the images FC was superior to THI, both techniques were identical in 37 % of cases, and in only 7 % THI was superior to FC. The following AUCs (Area under Curve, presence of pathology) were calculated: 0.945 and 0.969 for THI and FC, respectively (not significant). The two US techniques had comparable sensitivity (FC/THI 100/98 %) and specificity (FC/THI 76/74 %). CONCLUSION: Altogether, the diagnostic value of FC was comparable to that of THI with only slight differences. For ultrasound examinations of breast lesions, FC improves the image quality and conspicuity of pathology. SN - 0172-4614 UR - https://www.unboundmedicine.com/medline/citation/17602368/[Image_quality_and_characterisation_of_sonographically_detected_breast_lesions:_comparison_of_tissue_harmonic_imaging_alone_and_in_combination_with_frequency_compounding]_ L2 - https://www.thieme-connect.com/DOI/DOI?10.1055/s-2007-963041 DB - PRIME DP - Unbound Medicine ER -