Study of the determination of inorganic arsenic species by CE with capacitively coupled contactless conductivity detection.Electrophoresis. 2007 Oct; 28(19):3500-6.E
Abstract
The determination of arsenic(III) and arsenic(V), as inorganic arsenite and arsenate, was investigated by CE with capacitively coupled contactless conductivity detection (CE-C(4)D). It was found necessary to determine the two inorganic arsenic species separately employing two different electrolyte systems. Electrolyte solutions consisting of 50 mM CAPS/2 mM L-arginine (Arg) (pH 9.0) and of 45 mM acetic acid (pH 3.2) were used for arsenic(III) and arsenic(V) determinations, respectively. Detection limits of 0.29 and 0.15 microM were achieved for As(III) and As(V), respectively by using large-volume injection to maximize the sensitivity. The analysis of contaminated well water samples from Vietnam is demonstrated.
MeSH
Pub Type(s)
Journal Article
Research Support, Non-U.S. Gov't
Language
eng
PubMed ID
17768725
Citation
Nguyen, Huong Thi Anh, et al. "Study of the Determination of Inorganic Arsenic Species By CE With Capacitively Coupled Contactless Conductivity Detection." Electrophoresis, vol. 28, no. 19, 2007, pp. 3500-6.
Nguyen HT, Kubán P, Pham VH, et al. Study of the determination of inorganic arsenic species by CE with capacitively coupled contactless conductivity detection. Electrophoresis. 2007;28(19):3500-6.
Nguyen, H. T., Kubán, P., Pham, V. H., & Hauser, P. C. (2007). Study of the determination of inorganic arsenic species by CE with capacitively coupled contactless conductivity detection. Electrophoresis, 28(19), 3500-6.
Nguyen HT, et al. Study of the Determination of Inorganic Arsenic Species By CE With Capacitively Coupled Contactless Conductivity Detection. Electrophoresis. 2007;28(19):3500-6. PubMed PMID: 17768725.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - Study of the determination of inorganic arsenic species by CE with capacitively coupled contactless conductivity detection.
AU - Nguyen,Huong Thi Anh,
AU - Kubán,Pavel,
AU - Pham,Viet Hung,
AU - Hauser,Peter C,
PY - 2007/9/5/pubmed
PY - 2008/2/7/medline
PY - 2007/9/5/entrez
SP - 3500
EP - 6
JF - Electrophoresis
JO - Electrophoresis
VL - 28
IS - 19
N2 - The determination of arsenic(III) and arsenic(V), as inorganic arsenite and arsenate, was investigated by CE with capacitively coupled contactless conductivity detection (CE-C(4)D). It was found necessary to determine the two inorganic arsenic species separately employing two different electrolyte systems. Electrolyte solutions consisting of 50 mM CAPS/2 mM L-arginine (Arg) (pH 9.0) and of 45 mM acetic acid (pH 3.2) were used for arsenic(III) and arsenic(V) determinations, respectively. Detection limits of 0.29 and 0.15 microM were achieved for As(III) and As(V), respectively by using large-volume injection to maximize the sensitivity. The analysis of contaminated well water samples from Vietnam is demonstrated.
SN - 0173-0835
UR - https://www.unboundmedicine.com/medline/citation/17768725/Study_of_the_determination_of_inorganic_arsenic_species_by_CE_with_capacitively_coupled_contactless_conductivity_detection_
L2 - https://doi.org/10.1002/elps.200700069
DB - PRIME
DP - Unbound Medicine
ER -